Whatcom County, WA. Reports to the Puget Sound Energy balancing authorityThe organization that balances electricity supply and demand in a reporting area.Definition ↗.
Nameplate capacity, operating generatorsFull nameplate rating of the operating generators, before ownership shares. MW measures rated power; annual output is energy in MWh.Definition ↗
2MW
Source & method
Sum of generator nameplate MW with operational status code OP in the inventory year; one row per generator; unscaled by ownership
2024 inventory · reported · derived · valid · final
Net generationEnergy produced over the stated period after the plant’s own use, including signed storage output. Plant output is not allocated to owners or buyers.Definition ↗
-24MWh
2024
Source & method
Sum of EIA-923 annual net generation over the plant's unique prime-mover x energy-source rows; negative values (pumping, station use) retained
2024 calendar year · reported · derived · valid · final
Net generation MWh / (operating nameplate MW x hours in year); only when every operating generator was operating before the year began and none retired during it
2024 calendar year · reported · derived · valid · final
derived: net_generation_mwh@2024 / (nameplate_mw_op x 8784 h)
Ownership basisHow a generator's owners were established: from EIA-860's ownership schedule (reported), from EIA's rule that a unit absent from a complete schedule is wholly owned by its operator (derived), or unknown.Definition ↗
OwnerAn organization with a reported share of a generator. Owned MW applies that share to operating nameplate capacity; it does not establish who buys the output.Definition ↗Investor-owned utilityPuget Sound Energy ↗
2MW owned
Operating nameplate MW x ownership fraction, once per generator; reported schedule or EIA-860 schedule-4 default. Ownership source & rules ↗
Generators at this plant
Unscaled nameplateA generator’s rated maximum power, in MW. Capacity is a rating, not how much electricity it produced.Definition ↗
1 generators, including non-operating units where reported. Status is the inventory-year status.
Generator
Technology / statusWhether a generator or project is operating, planned, on standby or retired, as its source reports it.Definition ↗
NameplateA generator’s rated maximum power, in MW. Capacity is a rating, not how much electricity it produced.Definition ↗ · MW
Ownership basisHow a generator's owners were established: from EIA-860's ownership schedule (reported), from EIA's rule that a unit absent from a complete schedule is wholly owned by its operator (derived), or unknown.Definition ↗
This plant has no coal, gas, oil or waste generator, so it has no combustion unit for EPA to monitor and no CEMS data exists. That is not a claim of zero emissions: the atlas reports only what EPA-monitored units filed. Source
StorageBatteries, pumped hydro and other systems that store electricity for later use.Definition ↗ · Battery storage
Standalone
1 operating storage unit. Stores electricity; does not generate. Net output is net of chargingEnergy taken in to charge, energy returned, and their difference. Charging can make net generation negative.Definition ↗.
Storage discharge capacity, operating storage units
2MW
Source & method
Sum of nameplate MW over operating generators whose prime mover is a storage technology (BA, PS, FW, CE, CP, ES); a discharge rating, counted as its own resource row, never merged with generation MW
2024 inventory · reported · derived · valid · final
Sum of reported maximum charge rate MW (EIA-860 Schedule 3 Part B) over operating storage units that report it; batteries, flywheels and compressed air only
2024 inventory · reported · derived · valid · final
Sum of reported nameplate energy capacity MWh over operating storage units (EIA-860 line 34: batteries, flywheels, compressed air; null for pumped and thermal storage); unknown stays unknown
2024 inventory · reported · derived · valid · final
Nameplate energy MWh divided by nameplate MW, only when every unit has energy capacity and a positive reported discharge rate agreeing with nameplate within 0.05 MW; a nameplate ratio, not usable state of charge
2024 inventory · reported · derived · valid · final
1 of 1 operating storage units with verified duration included.
Charged, discharged and net energy of the storage units by calendar year (EIA-923). Net is signed; a round-trip ratio needs twelve reported months.
Year
Charged · MWh
Discharged · MWh
Net · MWh
Round tripDischarged energy divided by charged energy over a full reported year. A description, not an efficiency rating.Definition ↗
Months
2016
296MWh
257MWh
257MWh
Not supported for this scope
4
2017
907MWh
746MWh
746MWh
82 %
12
2018
1,652MWh
1,363MWh
-289MWh
83 %
12
2019
1,726MWh
1,468MWh
-258MWh
85 %
12
2020
65MWh
55MWh
-10MWh
85 %
12
2021
187MWh
81MWh
-106MWh
43 %
12
2022
186MWh
43MWh
-143MWh
23 %
12
2023
61MWh
7MWh
-54MWh
11 %
12
2024
25MWh
1MWh
-24MWh
4 %
12
A co-located plant's deliverable capacity is not the sum of its components (EIA-860 carries no interconnection limit). Net storage output is signed and is never added to generation shares.
Latest inventoryThe newest complete monthly inventory, with dated status and capacity changes beside the annual baseline totals.Definition ↗ · August 2026
Operating
No confirmed status or capacity changes among comparable units. Missing monthly assertions and units outside the baseline have no like-for-like comparison.
Operating nameplate capacity, latest inventoryOperating nameplate MW in this monthly inventory. Compare it with the annual baseline; do not add the two inventories together.Definition ↗
2MW
· provisional
Source & method
Sum of nameplate MW over generators whose current-valid EIA-860M workbook assertion has status OP; dated by the complete inventory edition; never added to the baseline aggregate
Planned nameplate capacity, latest inventoryNameplate MW proposed or under construction in this monthly inventory, separate from operating MW. Planned dates are forecasts.Definition ↗
Not applicable
· provisional
Source & method
Sum of nameplate MW over generators whose current-valid EIA-860M workbook assertion is a proposal or construction stage (P, L, T, U, V, OT, TS); a proposal is not a commitment and its date is a forecast
Retired or cancelled nameplate capacity, latest inventory
Not applicable
· provisional
Source & method
Sum of nameplate MW over generators whose current-valid EIA-860M workbook assertion is retired, cancelled or indefinitely postponed (RE, CN, IP); retired is not demolished
Each unit's operating span from its reported operating date to its retirement date or to the August 2026 inventory (the vertical line). Dashed spans start at a planned operating date, a forecast; a short bar marks a planned retirement. Standby and out-of-service units are hatched.
Units as a table
Unit lifecycle from EIA-860M, August 2026.
Unit
State
Operating since
Planned
Retired
MW
GLA
Operating
September 2016
—
—
2MW
Independently dated by EIA-860M; the baseline facts above stay the validated edition. Planned dates are forecasts; retired is not demolished.
Approximate service areasAn approximate utility service area. The boundary cannot identify the supplier for a particular address.Definition ↗ containing the plant’s location. A geographic candidate, not a supply relationship.
Storage discharge capacity, operating storage units
2MW
Source & method
Sum of nameplate MW over operating generators whose prime mover is a storage technology (BA, PS, FW, CE, CP, ES); a discharge rating, counted as its own resource row, never merged with generation MW
2024 inventory · reported · derived · valid · final
Catalyst Cooperative, PUDL v2026.9.0, derived from U.S. EIA Forms 860/923
Data transformed by PUDL from U.S. EIA forms; selected fields republished; EIA data is public with dated acknowledgment (https://www.eia.gov/about/copyrights_reuse.php)
Catalyst Cooperative, PUDL v2026.9.0, derived from U.S. EIA Forms 860/923
Data transformed by PUDL from U.S. EIA forms; selected fields republished; EIA data is public with dated acknowledgment (https://www.eia.gov/about/copyrights_reuse.php)
Catalyst Cooperative, PUDL v2026.9.0, derived from U.S. EIA Forms 860/923
Data transformed by PUDL from U.S. EIA forms; selected fields republished; EIA data is public with dated acknowledgment (https://www.eia.gov/about/copyrights_reuse.php)
Catalyst Cooperative, PUDL v2026.9.0, derived from U.S. EIA Forms 860/923
Data transformed by PUDL from U.S. EIA forms; selected fields republished; EIA data is public with dated acknowledgment (https://www.eia.gov/about/copyrights_reuse.php)