Klamath County, OR. Reports to the Avangrid Renewables balancing authorityThe organization that balances electricity supply and demand in a reporting area.Definition ↗.
Nameplate capacity, operating generatorsFull nameplate rating of the operating generators, before ownership shares. MW measures rated power; annual output is energy in MWh.Definition ↗
501.5MW
Source & method
Sum of generator nameplate MW with operational status code OP in the inventory year; one row per generator; unscaled by ownership
2024 inventory · reported · derived · valid · final
Net generationEnergy produced over the stated period after the plant’s own use, including signed storage output. Plant output is not allocated to owners or buyers.Definition ↗
3,664,854MWh
2024
Source & method
Sum of EIA-923 annual net generation over the plant's unique prime-mover x energy-source rows; negative values (pumping, station use) retained
2024 calendar year · reported · derived · valid · final
Net generation MWh / (operating nameplate MW x hours in year); only when every operating generator was operating before the year began and none retired during it
2024 calendar year · reported · derived · valid · final
derived: net_generation_mwh@2024 / (nameplate_mw_op x 8784 h)
Ownership basisHow a generator's owners were established: from EIA-860's ownership schedule (reported), from EIA's rule that a unit absent from a complete schedule is wholly owned by its operator (derived), or unknown.Definition ↗
OwnerAn organization with a reported share of a generator. Owned MW applies that share to operating nameplate capacity; it does not establish who buys the output.Definition ↗Independent power producerAvangrid Renewables ↗
501.5MW owned
Operating nameplate MW x ownership fraction, once per generator; reported schedule or EIA-860 schedule-4 default. Ownership source & rules ↗
Generators at this plant
Unscaled nameplateA generator’s rated maximum power, in MW. Capacity is a rating, not how much electricity it produced.Definition ↗
3 generators, including non-operating units where reported. Status is the inventory-year status.
Generator
Technology / statusWhether a generator or project is operating, planned, on standby or retired, as its source reports it.Definition ↗
NameplateA generator’s rated maximum power, in MW. Capacity is a rating, not how much electricity it produced.Definition ↗ · MW
Ownership basisHow a generator's owners were established: from EIA-860's ownership schedule (reported), from EIA's rule that a unit absent from a complete schedule is wholly owned by its operator (derived), or unknown.Definition ↗
CO2 filed by EPA-monitored unitsAn EPA emissions unit (a combustor or stack) with CEMS rows in the year, linked to EIA generators through the EPA-EIA crosswalk. A plant is fully monitored when every existing coal, gas, oil or waste generator is linked to one; otherwise its monitored CO2 is shown but never as the plant's total.Definition ↗
2024 · metered
2 monitored units covering 3 of 3 combustion generators, 501.5 of 501.5 MW. 100.0% of operating unit-hours carry EPA’s measured flag; the rest are substitute dataHours a unit filled under Part 75 missing-data procedures instead of a monitor reading; EPA flags each hour Measured, Substitute or Measured and Substitute. Substitute values are designed to err high. The atlas counts these hours, and a plant's CO2 fact is metered only when at least 99 percent of its operating unit-hours were measured.Definition ↗.
CO2 mass, monitored units
1,443,821t CO2
2024·metered
Source & method
Sum of hourly CO2 mass reported under 40 CFR Part 75 by the plant's EPA-monitored units over the reporting year, short tons x 0.90718474. Stack total of those units including any share attributable to steam sold; the plant's total only where every combustion generator is monitored
2024 calendar year · metered · derived · valid · final
Monitored-unit CO2 (tonnes) divided by the plant's EIA-923 net generation for the same year. Only where every combustion generator is monitored, so numerator and denominator cover the same plant; comparable across such plants
2024 calendar year · metered · derived · valid · final
Monitored-unit CO2 (tonnes) divided by the same units' reported gross load. Only where every combustion generator is monitored and the gross load is not below EIA net generation; gross, so lower than the net figure, and not comparable with it
2024 calendar year · metered · derived · valid · final
Each reporting year as filed and set against that year’s own generator inventory. Years sit side by side; no change between them is computed, because the monitored units can differ.
Year
CO2t CO2
Evidence
Measured shareof operating unit-hours
Net intensityt CO2/MWh
2023
1,137,833
metered2 units, 3 of 3 generators
100.0%
0.395
2024
1,443,821
metered2 units, 3 of 3 generators
100.0%
0.394
Every figure filed
Figure
Value
Basis
CO2 mass, monitored units
1,443,821 t CO2
Sum of hourly CO2 mass reported under 40 CFR Part 75 by the plant's EPA-monitored units over the reporting year, short tons x 0.90718474. Stack total of those units including any share attributable to steam sold; the plant's total only where every combustion generator is monitored
CO2 mass, monitored units, as filed
1,591,540 short tons CO2
The same sum in the unit EPA's files use (short tons); shown beside the metric figure so the conversion is visible
Gross load of monitored units
3,786,650 MWh
Sum over the year of each monitored unit's reported hourly gross load (MW) x operating time (h). A unit-reported quantity: a combined-cycle unit need not include its steam turbine, so this can be below EIA net generation
Heat input of monitored units
26,780,630 mmBtu
Sum over the year of each monitored unit's reported hourly heat input
Unit operating hours, monitored units
15,520.8 h
Sum of reported operating time over the plant's monitored units: unit-hours, so it can exceed the hours in the year when several units ran
Hours in which a monitored unit ran
7,881 count
Calendar hours of the reporting year in which at least one monitored unit reported operating time; never above the hours in the year
EPA emissions units with CEMS rows
2 count
Distinct EPA emissions units at the plant with rows in the reporting year; an EPA unit is a combustor or stack, not an EIA generator
Combustion generators linked to a monitored unit
3 count
Existing coal, gas, oil or waste generators of the plant (EIA-860 inventory year) that the EPA-EIA crosswalk links to a unit with CEMS rows; a steam turbine linked to several combustion turbines counts once
Combustion generators at the plant
3 count
Existing (operating, standby or out of service) generators whose resource group is coal, gas, oil or waste in the EIA-860 inventory year: the units that could be monitored
Share of operating unit-hours with measured CO2
0.9999 fraction
Operating unit-hours EPA flagged Measured divided by all operating unit-hours of the plant's monitored units; the rest were Substitute, Measured and Substitute, or another method code
CO2 per MWh of net generation
0.394 t CO2/MWh
Monitored-unit CO2 (tonnes) divided by the plant's EIA-923 net generation for the same year. Only where every combustion generator is monitored, so numerator and denominator cover the same plant; comparable across such plants
CO2 per MWh of gross load (unit-reported)
0.381 t CO2/MWh
Monitored-unit CO2 (tonnes) divided by the same units' reported gross load. Only where every combustion generator is monitored and the gross load is not below EIA net generation; gross, so lower than the net figure, and not comparable with it
CO2 reported hourly under 40 CFR Part 75 by this plant's EPA-monitored units and summed over the reporting year, as filed (short tons) and in tonnes. It is a stack total of those units, includes any share attributable to steam sold, and is not CO2-equivalent, lifecycle or consumption-based. EPA-monitored units are one program's population: the figure is not a regional total and an unmonitored plant is not zero. Evidence rule: metered where at least 99% of the plant's operating unit-hours carry EPA's Measured flag, estimated where more were Substitute, Measured and Substitute or another method code. Source and notice· matched through EPA’s crosswalk.
Latest inventoryThe newest complete monthly inventory, with dated status and capacity changes beside the annual baseline totals.Definition ↗ · August 2026
Operating
No confirmed status or capacity changes among comparable units. Missing monthly assertions and units outside the baseline have no like-for-like comparison.
Operating nameplate capacity, latest inventoryOperating nameplate MW in this monthly inventory. Compare it with the annual baseline; do not add the two inventories together.Definition ↗
501.5MW
· provisional
Source & method
Sum of nameplate MW over generators whose current-valid EIA-860M workbook assertion has status OP; dated by the complete inventory edition; never added to the baseline aggregate
Planned nameplate capacity, latest inventoryNameplate MW proposed or under construction in this monthly inventory, separate from operating MW. Planned dates are forecasts.Definition ↗
Not applicable
· provisional
Source & method
Sum of nameplate MW over generators whose current-valid EIA-860M workbook assertion is a proposal or construction stage (P, L, T, U, V, OT, TS); a proposal is not a commitment and its date is a forecast
Retired or cancelled nameplate capacity, latest inventory
Not applicable
· provisional
Source & method
Sum of nameplate MW over generators whose current-valid EIA-860M workbook assertion is retired, cancelled or indefinitely postponed (RE, CN, IP); retired is not demolished
Each unit's operating span from its reported operating date to its retirement date or to the August 2026 inventory (the vertical line). Dashed spans start at a planned operating date, a forecast; a short bar marks a planned retirement. Standby and out-of-service units are hatched.
Units as a table
Unit lifecycle from EIA-860M, August 2026.
Unit
State
Operating since
Planned
Retired
MW
CT1
Operating
July 2001
—
—
161.5MW
CT2
Operating
July 2001
—
—
161.5MW
ST1
Operating
July 2001
—
—
178.5MW
Independently dated by EIA-860M; the baseline facts above stay the validated edition. Planned dates are forecasts; retired is not demolished.
Approximate service areasAn approximate utility service area. The boundary cannot identify the supplier for a particular address.Definition ↗ containing the plant’s location. A geographic candidate, not a supply relationship.
Within 3 km of the reported plant point, nearest first. BPA’s published lines, HIFLD-compiled lines of other owners and HIFLD 2022 substations; nearness does not establish an electrical connection.
Catalyst Cooperative, PUDL v2026.9.0, derived from U.S. EIA Forms 860/923
Data transformed by PUDL from U.S. EIA forms; selected fields republished; EIA data is public with dated acknowledgment (https://www.eia.gov/about/copyrights_reuse.php)
Catalyst Cooperative, PUDL v2026.9.0, derived from U.S. EIA Forms 860/923
Data transformed by PUDL from U.S. EIA forms; selected fields republished; EIA data is public with dated acknowledgment (https://www.eia.gov/about/copyrights_reuse.php)
Catalyst Cooperative, PUDL v2026.9.0, derived from U.S. EIA Forms 860/923
Data transformed by PUDL from U.S. EIA forms; selected fields republished; EIA data is public with dated acknowledgment (https://www.eia.gov/about/copyrights_reuse.php)
Catalyst Cooperative, PUDL v2026.9.0, derived from U.S. EIA Forms 860/923
Data transformed by PUDL from U.S. EIA forms; selected fields republished; EIA data is public with dated acknowledgment (https://www.eia.gov/about/copyrights_reuse.php)
Catalyst Cooperative, PUDL v2026.9.0, derived from U.S. EPA CAMD Power Sector Emissions Data
Data transformed by PUDL from U.S. EPA Clean Air Markets Division hourly emissions files; selected fields for two reporting years and four states republished; EPA data is public (https://www.epa.gov/power-sector/power-sector-data)