 "aliases": [
  {
   "relation": "exact",
   "review_state": "source",
   "source_entity_id": "3075",
   "source_ref": "pudl-plants"
  },
  {
   "basis": "EHA 2026 EIA_PtID 3075 = EIA plant; state OR; EHA point 0.06 km from EIA point; names share a token; HILARRI v4 links EHA id to NID OR00001 (Bonneville Locks and Dam, Columbia River), NID point 0.02 km from EIA point; NID purposes: Navigation;Other;Recreation;Hydroelectric",
   "evidence_url": "https://hydrosource.ornl.gov/data/datasets/hilarri-v4/",
   "kind": "hydro_plant",
   "name": "Bonneville",
   "note": "Hydropower is a reported purpose in the NID. Associated power plant is included in the EHA.; NHDPlusV2",
   "relation": "exact",
   "review_state": "reviewed",
   "reviewed_on": "2026-09-21",
   "source_entity_id": "hc0208_p01",
   "source_ref": "ornl-eha-2026",
   "source_url": "https://hydrosource.ornl.gov/data/datasets/eha-plant-2026/",
   "water": "Columbia River"
  },
  {
   "basis": "EHA 2026 EIA_PtID 3075 = EIA plant; state OR; EHA point 0.06 km from EIA point; names share a token; HILARRI v4 links EHA id to NID OR00001 (Bonneville Locks and Dam, Columbia River), NID point 0.02 km from EIA point; NID purposes: Navigation;Other;Recreation;Hydroelectric",
   "evidence_url": "https://hydrosource.ornl.gov/data/datasets/hilarri-v4/",
   "kind": "dam",
   "name": "Bonneville Locks and Dam",
   "note": "Hydropower is a reported purpose in the NID. Associated power plant is included in the EHA.; NHDPlusV2",
   "relation": "component",
   "review_state": "reviewed",
   "reviewed_on": "2026-09-21",
   "source_entity_id": "OR00001",
   "source_ref": "usace-nid",
   "source_url": "https://nid.sec.usace.army.mil/"
  },
  {
   "basis": "EHA 2026 EIA_PtID 3075 = EIA plant; state OR; EHA point 0.06 km from EIA point; names share a token; HILARRI v4 links EHA id to NID OR00001 (Bonneville Locks and Dam, Columbia River), NID point 0.02 km from EIA point; NID purposes: Navigation;Other;Recreation;Hydroelectric",
   "evidence_url": "https://hydrosource.ornl.gov/data/datasets/hilarri-v4/",
   "ids": {
    "grand_id": null,
    "huc12": "170800010801",
    "nhdplusv2_comid": "23736161"
   },
   "kind": "water_links",
   "name": null,
   "note": "Hydropower is a reported purpose in the NID. Associated power plant is included in the EHA.; NHDPlusV2",
   "relation": "exact",
   "review_state": "reviewed",
   "reviewed_on": "2026-09-21",
   "source_entity_id": "2218",
   "source_ref": "ornl-hilarri-v4",
   "source_url": "https://hydrosource.ornl.gov/data/datasets/hilarri-v4/"
  },
  {
   "basis": "USACE's NIDID agency-alias group maps NID OR00001 (this plant's reviewed dam) to NWDP location BON; CWMS location 'Bonneville Lock and Dam' is a PROJECT in OR, 0.25 km from the EIA plant point; its name shares 'bonneville' with the NID dam name",
   "evidence_url": "https://cwms-data.usace.army.mil/cwms-data/location/group/NIDID?office=CWMS&category-id=Agency%20Aliases&group-office-id=CWMS",
   "kind": "cwms_location",
   "name": "Bonneville Lock and Dam",
   "note": null,
   "office": "NWDP",
   "relation": "component",
   "review_state": "reviewed",
   "reviewed_on": "2026-09-28",
   "source_entity_id": "BON",
   "source_ref": "usace-cwms-history",
   "source_url": "https://cwms-data.usace.army.mil/cwms-data/locations/BON?office=NWDP"
  },
  {
   "kind": "display_name",
   "note": "usace project name",
   "relation": "exact",
   "review_state": "reviewed",
   "reviewed_on": "2026-09-18",
   "source_entity_id": "Bonneville Lock and Dam",
   "source_ref": "curated-aliases",
   "source_url": "https://www.nwp.usace.army.mil/Locations/Columbia-River/"
  }
 ],
 "citation_path": "citations/plant~eia~3075.html",
 "context": {
  "nearby_bpa_lines": [
   {
    "distance_km": 0.49,
    "id": "line:bpa:BNPH-NBON-3",
    "name": "Bonneville PH 2-North Bonneville No 3",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "230",
    "voltage_kv": 230.0
   },
   {
    "distance_km": 0.53,
    "id": "line:bpa:BOPH-ALCO-2",
    "name": "Bonneville PH 1-Alcoa 1&2 No 2",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "115-161",
    "voltage_kv": 115.0
   },
   {
    "distance_km": 0.56,
    "id": "line:bpa:BOPH-NCAM-1",
    "name": "Bonneville PH 1-North Camas No 1",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "115-161",
    "voltage_kv": 115.0
   },
   {
    "distance_km": 0.57,
    "id": "line:bpa:BNPH-NBON-4",
    "name": "Bonneville PH 2-North Bonneville No 4",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "230",
    "voltage_kv": 230.0
   },
   {
    "distance_km": 0.61,
    "id": "line:bpa:BOPH-NBON-2",
    "name": "Bonneville PH 1-North Bonneville No 2",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "230",
    "voltage_kv": 230.0
   },
   {
    "distance_km": 0.66,
    "id": "line:bpa:BOPH-NBON-1",
    "name": "Bonneville PH 1-North Bonneville No 1",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "230",
    "voltage_kv": 230.0
   },
   {
    "distance_km": 0.75,
    "id": "line:bpa:BOPH-HORV-1",
    "name": "Bonneville PH 1-Hood River No 1",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "115-161",
    "voltage_kv": 115.0
   },
   {
    "distance_km": 0.84,
    "id": "line:bpa:KNIT-OSTD-1",
    "name": "Knight-Ostrander No 1",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "500",
    "voltage_kv": 500.0
   },
   {
    "distance_km": 1.55,
    "id": "line:bpa:UNDDT-BONC-1",
    "name": "Underwood Tap to Bonneville PH 1-North Camas No 1",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "115-161",
    "voltage_kv": 115.0
   },
   {
    "distance_km": 1.58,
    "id": "line:bpa:UNDDT-BOAL-2",
    "name": "Underwood Tap to Bonneville PH 1-Alcoa No 1&2 No 2",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "115-161",
    "voltage_kv": 115.0
   },
   {
    "distance_km": 1.58,
    "id": "line:bpa:NBON-MIDW-1",
    "name": "North Bonneville-Midway No 1",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "230",
    "voltage_kv": 230.0
   },
   {
    "distance_km": 1.59,
    "id": "line:bpa:NBON-TROU-2",
    "name": "North Bonneville-Troutdale No 2",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "230",
    "voltage_kv": 230.0
   },
   {
    "distance_km": 1.6,
    "id": "line:bpa:NBON-ROSS-2",
    "name": "North Bonneville-Ross No 2",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "230",
    "voltage_kv": 230.0
   },
   {
    "distance_km": 1.62,
    "id": "line:bpa:NBON-ROSS-1",
    "name": "North Bonneville-Ross No 1",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "230",
    "voltage_kv": 230.0
   },
   {
    "distance_km": 1.63,
    "id": "line:bpa:NBON-TROU-1",
    "name": "North Bonneville-Troutdale No 1",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "230",
    "voltage_kv": 230.0
   }
  ],
  "nearby_bpa_lines_status": {
   "available": true,
   "method": "Planar distance in the CONUS Albers projection (EPSG:5070) from the reported plant point to the published geometry, within about 1% in the region; features within 3 km, nearest first. Context only: nearness is not an electrical connection.",
   "note": "nearby_lines holds BPA's published lines and HIFLD-compiled lines of other owners (source_ref on each row); nearby_bpa_lines is the BPA subset; substations are HIFLD 2022 points at 100 kV and above",
   "radius_km": 3.0,
   "reason": null
  },
  "nearby_lines": [
   {
    "distance_km": 0.49,
    "id": "line:bpa:BNPH-NBON-3",
    "name": "Bonneville PH 2-North Bonneville No 3",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "230",
    "voltage_kv": 230.0
   },
   {
    "distance_km": 0.53,
    "id": "line:bpa:BOPH-ALCO-2",
    "name": "Bonneville PH 1-Alcoa 1&2 No 2",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "115-161",
    "voltage_kv": 115.0
   },
   {
    "distance_km": 0.56,
    "id": "line:bpa:BOPH-NCAM-1",
    "name": "Bonneville PH 1-North Camas No 1",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "115-161",
    "voltage_kv": 115.0
   },
   {
    "distance_km": 0.57,
    "id": "line:bpa:BNPH-NBON-4",
    "name": "Bonneville PH 2-North Bonneville No 4",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "230",
    "voltage_kv": 230.0
   },
   {
    "distance_km": 0.61,
    "id": "line:bpa:BOPH-NBON-2",
    "name": "Bonneville PH 1-North Bonneville No 2",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "230",
    "voltage_kv": 230.0
   },
   {
    "distance_km": 0.66,
    "id": "line:bpa:BOPH-NBON-1",
    "name": "Bonneville PH 1-North Bonneville No 1",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "230",
    "voltage_kv": 230.0
   },
   {
    "distance_km": 0.75,
    "id": "line:bpa:BOPH-HORV-1",
    "name": "Bonneville PH 1-Hood River No 1",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "115-161",
    "voltage_kv": 115.0
   },
   {
    "distance_km": 0.84,
    "id": "line:bpa:KNIT-OSTD-1",
    "name": "Knight-Ostrander No 1",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "500",
    "voltage_kv": 500.0
   },
   {
    "distance_km": 1.55,
    "id": "line:bpa:UNDDT-BONC-1",
    "name": "Underwood Tap to Bonneville PH 1-North Camas No 1",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "115-161",
    "voltage_kv": 115.0
   },
   {
    "distance_km": 1.58,
    "id": "line:bpa:UNDDT-BOAL-2",
    "name": "Underwood Tap to Bonneville PH 1-Alcoa No 1&2 No 2",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "115-161",
    "voltage_kv": 115.0
   },
   {
    "distance_km": 1.58,
    "id": "line:bpa:NBON-MIDW-1",
    "name": "North Bonneville-Midway No 1",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "230",
    "voltage_kv": 230.0
   },
   {
    "distance_km": 1.59,
    "id": "line:bpa:NBON-TROU-2",
    "name": "North Bonneville-Troutdale No 2",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "230",
    "voltage_kv": 230.0
   },
   {
    "distance_km": 1.6,
    "id": "line:bpa:NBON-ROSS-2",
    "name": "North Bonneville-Ross No 2",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "230",
    "voltage_kv": 230.0
   },
   {
    "distance_km": 1.62,
    "id": "line:bpa:NBON-ROSS-1",
    "name": "North Bonneville-Ross No 1",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "230",
    "voltage_kv": 230.0
   },
   {
    "distance_km": 1.63,
    "id": "line:bpa:NBON-TROU-1",
    "name": "North Bonneville-Troutdale No 1",
    "source_ref": "bpa-lines",
    "type": "line",
    "voltage_class": "230",
    "voltage_kv": 230.0
   }
  ],
  "nearby_substations": [
   {
    "distance_km": 1.02,
    "id": "substation:hifld:200939",
    "kind": "SUBSTATION",
    "max_kv": 115.0,
    "name": "ACTON",
    "source_ref": "hifld-substations-2022",
    "type": "substation"
   },
   {
    "distance_km": 1.57,
    "id": "substation:hifld:200480",
    "kind": "SUBSTATION",
    "max_kv": 230.0,
    "name": "NORTH BONNEVILLE",
    "source_ref": "hifld-substations-2022",
    "type": "substation"
   }
  ],
  "territories": [
   {
    "id": "territory:odoe:30",
    "name": "City of Cascade Locks",
    "note": "Plant coordinate lies inside this approximate territory polygon; candidate only, not a supply or service relationship",
    "relation": "candidate",
    "source_ref": "or-odoe-territories"
   }
  ]
 },
 "coverage": {
  "generators_eligible": 20,
  "generators_operating": 11,
  "generators_published": 20,
  "output_years": [
   2015,
   2016,
   2017,
   2018,
   2019,
   2020,
   2021,
   2022,
   2023,
   2024
  ],
  "ownership_known_generators": 20
 },
 "disclosed_claims": {
  "note": "Washington Fuel Mix Disclosure claims on this plant for CY2024, the latest year loaded; several suppliers can claim one plant; a claim attributes retail sales, it is not a wire or a share of ownership",
  "report_year": 2024,
  "rows": [],
  "source_ref": "wa-fmd-2024-by-plant"
 },
 "emissions": {
  "available": false,
  "generators_monitored": 0,
  "generators_total": 0,
  "history": [],
  "note": "This plant has no coal, gas, oil or waste generator, so it has no combustion unit for EPA to monitor and no CEMS data exists. That is not a claim of zero emissions: the atlas reports only what EPA-monitored units filed.",
  "reason": "not_applicable",
  "source_ref": "pudl-epacems",
  "units_monitored": 0,
  "year": 2024
 },
 "events": [],
 "facts": [
  {
   "basis": "Sum of generator nameplate MW with operational status code OP in the inventory year; one row per generator; unscaled by ownership",
   "coverage": {
    "eligible": 11,
    "included": 11,
    "unit": "operating generators"
   },
   "denominator": null,
   "evidence": "reported",
   "fact_id": "plant:eia:3075#nameplate_mw_op@2024",
   "label": "Nameplate capacity, operating generators",
   "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075",
   "maturity": "final",
   "method": "derived",
   "metric": "nameplate_mw_op",
   "missing_reason": null,
   "note": null,
   "period": {
    "kind": "inventory_year",
    "note": "EIA-860 annual inventory; status as of the end of the reporting year",
    "report_date": "2024-01-01",
    "year": 2024
   },
   "precision": 1,
   "quality": "valid",
   "source_ref": "pudl-generators",
   "unit": "MW",
   "value": 656.3
  },
  {
   "basis": "Generator rows for the plant in the inventory year, any status",
   "coverage": null,
   "denominator": null,
   "evidence": "reported",
   "fact_id": "plant:eia:3075#generator_count@2024",
   "label": "Generators listed",
   "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075",
   "maturity": "final",
   "method": "derived",
   "metric": "generator_count",
   "missing_reason": null,
   "note": null,
   "period": {
    "kind": "inventory_year",
    "note": "EIA-860 annual inventory; status as of the end of the reporting year",
    "report_date": "2024-01-01",
    "year": 2024
   },
   "precision": 0,
   "quality": "valid",
   "source_ref": "pudl-generators",
   "unit": "count",
   "value": 20.0
  },
  {
   "basis": "Generator rows with status code OP",
   "coverage": null,
   "denominator": null,
   "evidence": "reported",
   "fact_id": "plant:eia:3075#generator_count_op@2024",
   "label": "Operating generators",
   "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075",
   "maturity": "final",
   "method": "derived",
   "metric": "generator_count_op",
   "missing_reason": null,
   "note": null,
   "period": {
    "kind": "inventory_year",
    "note": "EIA-860 annual inventory; status as of the end of the reporting year",
    "report_date": "2024-01-01",
    "year": 2024
   },
   "precision": 0,
   "quality": "valid",
   "source_ref": "pudl-generators",
   "unit": "count",
   "value": 11.0
  },
  {
   "basis": "Sum of generator nameplate MW with status category existing and code other than OP (SB, OS, OA)",
   "coverage": null,
   "denominator": null,
   "evidence": "reported",
   "fact_id": "plant:eia:3075#nameplate_mw_existing_not_operating@2024",
   "label": "Nameplate capacity, existing but not operating (standby / out of service)",
   "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075",
   "maturity": "final",
   "method": "derived",
   "metric": "nameplate_mw_existing_not_operating",
   "missing_reason": null,
   "note": null,
   "period": {
    "kind": "inventory_year",
    "note": "EIA-860 annual inventory; status as of the end of the reporting year",
    "report_date": "2024-01-01",
    "year": 2024
   },
   "precision": 1,
   "quality": "valid",
   "source_ref": "pudl-generators",
   "unit": "MW",
   "value": 505.70000000000005
  },
  {
   "basis": "Sum of EIA-923 annual net generation over the plant's unique prime-mover x energy-source rows; negative values (pumping, station use) retained",
   "coverage": {
    "eligible": 1,
    "included": 1,
    "unit": "plant x prime-mover x fuel rows"
   },
   "denominator": null,
   "evidence": "reported",
   "fact_id": "plant:eia:3075#net_generation_mwh@2024",
   "label": "Net generation",
   "locator": "out_eia923__yearly_generation_fuel_combined.parquet; report_date=2024-01-01; plant_id_eia=3075",
   "maturity": "final",
   "method": "derived",
   "metric": "net_generation_mwh",
   "missing_reason": null,
   "note": null,
   "period": {
    "hours": 8784,
    "kind": "calendar_year",
    "period_end": "2025-01-01T00:00:00Z",
    "period_start": "2024-01-01T00:00:00Z",
    "year": 2024
   },
   "precision": 0,
   "quality": "valid",
   "source_ref": "pudl-output",
   "unit": "MWh",
   "value": 3492864.0
  },
  {
   "basis": "Net generation MWh / (operating nameplate MW x hours in year); only when every operating generator was operating before the year began and none retired during it",
   "coverage": null,
   "denominator": {
    "hours": 8784,
    "metric": "nameplate_mw_op",
    "unit": "MW",
    "value": 656.3
   },
   "evidence": "reported",
   "fact_id": "plant:eia:3075#capacity_factor@2024",
   "label": "Capacity factor",
   "locator": "derived: net_generation_mwh@2024 / (nameplate_mw_op x 8784 h)",
   "maturity": "final",
   "method": "derived",
   "metric": "capacity_factor",
   "missing_reason": null,
   "note": null,
   "period": {
    "hours": 8784,
    "kind": "calendar_year",
    "period_end": "2025-01-01T00:00:00Z",
    "period_start": "2024-01-01T00:00:00Z",
    "year": 2024
   },
   "precision": 3,
   "quality": "valid",
   "source_ref": "pudl-output",
   "unit": "fraction",
   "value": 0.6058804575076873
  }
 ],
 "generators": [
  {
   "dates": {
    "note": "EIA-860 reports month and year; day is a placeholder",
    "operating": "1938-07-01",
    "original_planned_operating": null,
    "planned_operating": null,
    "planned_retirement": null,
    "precision": "month",
    "retirement": null
   },
   "energy_source": {
    "code": "WAT",
    "fuel_group": "hydro",
    "label": "water"
   },
   "facts": [
    {
     "basis": "Generator nameplate capacity as reported on EIA-860",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:1#capacity_mw@2024",
     "label": "Nameplate capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=1",
     "maturity": "final",
     "method": "derived",
     "metric": "capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 53.5
    },
    {
     "basis": "Reported or source-estimated net summer capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:1#summer_capacity_mw@2024",
     "label": "Net summer capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=1",
     "maturity": "final",
     "method": "derived",
     "metric": "summer_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 53.5
    },
    {
     "basis": "Reported or source-estimated net winter capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:1#winter_capacity_mw@2024",
     "label": "Net winter capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=1",
     "maturity": "final",
     "method": "derived",
     "metric": "winter_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 53.5
    }
   ],
   "generator_id": "1",
   "id": "generator:eia:3075:1",
   "is_storage": false,
   "operator": {
    "entity_type": "F",
    "entity_type_label": "Federally-owned utility",
    "id": "org:eia:19400",
    "name": "U.S. Army Corps of Engineers, Northwestern Division"
   },
   "ownership": {
    "basis": "eia860_schedule4_default",
    "invalid_shares": false,
    "note": null,
    "shares": [
     {
      "basis": "eia860_schedule4_default",
      "evidence": "reported",
      "fraction": 1.0,
      "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=1; ownership_code=S; rule=eia860_schedule4_default",
      "method": "derived",
      "owned_mw": 53.5,
      "owner": {
       "entity_type": "F",
       "entity_type_label": "Federally-owned utility",
       "id": "org:eia:19400",
       "name": "U.S. Army Corps of Engineers, Northwestern Division"
      },
      "reason": "eia860_schedule4_default",
      "source_ref": "pudl-generators"
     }
    ],
    "unassigned_fraction": 0.0,
    "unassigned_mw": 0.0,
    "unknown_reason": null
   },
   "prime_mover": {
    "code": "HY",
    "label": "hydraulic_turbine"
   },
   "resource_group": "hydro",
   "status": {
    "category": "existing",
    "code": "OP",
    "label": "operating"
   },
   "storage": null,
   "technology": "Conventional Hydroelectric"
  },
  {
   "dates": {
    "note": "EIA-860 reports month and year; day is a placeholder",
    "operating": "1944-01-01",
    "original_planned_operating": null,
    "planned_operating": null,
    "planned_retirement": null,
    "precision": "month",
    "retirement": null
   },
   "energy_source": {
    "code": "WAT",
    "fuel_group": "hydro",
    "label": "water"
   },
   "facts": [
    {
     "basis": "Generator nameplate capacity as reported on EIA-860",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:10#capacity_mw@2024",
     "label": "Nameplate capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=10",
     "maturity": "final",
     "method": "derived",
     "metric": "capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 62.1
    },
    {
     "basis": "Reported or source-estimated net summer capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:10#summer_capacity_mw@2024",
     "label": "Net summer capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=10",
     "maturity": "final",
     "method": "derived",
     "metric": "summer_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 54.0
    },
    {
     "basis": "Reported or source-estimated net winter capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:10#winter_capacity_mw@2024",
     "label": "Net winter capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=10",
     "maturity": "final",
     "method": "derived",
     "metric": "winter_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 54.0
    }
   ],
   "generator_id": "10",
   "id": "generator:eia:3075:10",
   "is_storage": false,
   "operator": {
    "entity_type": "F",
    "entity_type_label": "Federally-owned utility",
    "id": "org:eia:19400",
    "name": "U.S. Army Corps of Engineers, Northwestern Division"
   },
   "ownership": {
    "basis": "eia860_schedule4_default",
    "invalid_shares": false,
    "note": null,
    "shares": [
     {
      "basis": "eia860_schedule4_default",
      "evidence": "reported",
      "fraction": 1.0,
      "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=10; ownership_code=S; rule=eia860_schedule4_default",
      "method": "derived",
      "owned_mw": 62.1,
      "owner": {
       "entity_type": "F",
       "entity_type_label": "Federally-owned utility",
       "id": "org:eia:19400",
       "name": "U.S. Army Corps of Engineers, Northwestern Division"
      },
      "reason": "eia860_schedule4_default",
      "source_ref": "pudl-generators"
     }
    ],
    "unassigned_fraction": 0.0,
    "unassigned_mw": 0.0,
    "unknown_reason": null
   },
   "prime_mover": {
    "code": "HY",
    "label": "hydraulic_turbine"
   },
   "resource_group": "hydro",
   "status": {
    "category": "existing",
    "code": "OA",
    "label": "out_of_service_short_term"
   },
   "storage": null,
   "technology": "Conventional Hydroelectric"
  },
  {
   "dates": {
    "note": "EIA-860 reports month and year; day is a placeholder",
    "operating": "1982-10-01",
    "original_planned_operating": null,
    "planned_operating": null,
    "planned_retirement": null,
    "precision": "month",
    "retirement": null
   },
   "energy_source": {
    "code": "WAT",
    "fuel_group": "hydro",
    "label": "water"
   },
   "facts": [
    {
     "basis": "Generator nameplate capacity as reported on EIA-860",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:11#capacity_mw@2024",
     "label": "Nameplate capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=11",
     "maturity": "final",
     "method": "derived",
     "metric": "capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    },
    {
     "basis": "Reported or source-estimated net summer capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:11#summer_capacity_mw@2024",
     "label": "Net summer capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=11",
     "maturity": "final",
     "method": "derived",
     "metric": "summer_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    },
    {
     "basis": "Reported or source-estimated net winter capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:11#winter_capacity_mw@2024",
     "label": "Net winter capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=11",
     "maturity": "final",
     "method": "derived",
     "metric": "winter_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    }
   ],
   "generator_id": "11",
   "id": "generator:eia:3075:11",
   "is_storage": false,
   "operator": {
    "entity_type": "F",
    "entity_type_label": "Federally-owned utility",
    "id": "org:eia:19400",
    "name": "U.S. Army Corps of Engineers, Northwestern Division"
   },
   "ownership": {
    "basis": "eia860_schedule4_default",
    "invalid_shares": false,
    "note": null,
    "shares": [
     {
      "basis": "eia860_schedule4_default",
      "evidence": "reported",
      "fraction": 1.0,
      "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=11; ownership_code=S; rule=eia860_schedule4_default",
      "method": "derived",
      "owned_mw": 66.5,
      "owner": {
       "entity_type": "F",
       "entity_type_label": "Federally-owned utility",
       "id": "org:eia:19400",
       "name": "U.S. Army Corps of Engineers, Northwestern Division"
      },
      "reason": "eia860_schedule4_default",
      "source_ref": "pudl-generators"
     }
    ],
    "unassigned_fraction": 0.0,
    "unassigned_mw": 0.0,
    "unknown_reason": null
   },
   "prime_mover": {
    "code": "HY",
    "label": "hydraulic_turbine"
   },
   "resource_group": "hydro",
   "status": {
    "category": "existing",
    "code": "OP",
    "label": "operating"
   },
   "storage": null,
   "technology": "Conventional Hydroelectric"
  },
  {
   "dates": {
    "note": "EIA-860 reports month and year; day is a placeholder",
    "operating": "1982-10-01",
    "original_planned_operating": null,
    "planned_operating": null,
    "planned_retirement": null,
    "precision": "month",
    "retirement": null
   },
   "energy_source": {
    "code": "WAT",
    "fuel_group": "hydro",
    "label": "water"
   },
   "facts": [
    {
     "basis": "Generator nameplate capacity as reported on EIA-860",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:12#capacity_mw@2024",
     "label": "Nameplate capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=12",
     "maturity": "final",
     "method": "derived",
     "metric": "capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    },
    {
     "basis": "Reported or source-estimated net summer capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:12#summer_capacity_mw@2024",
     "label": "Net summer capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=12",
     "maturity": "final",
     "method": "derived",
     "metric": "summer_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    },
    {
     "basis": "Reported or source-estimated net winter capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:12#winter_capacity_mw@2024",
     "label": "Net winter capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=12",
     "maturity": "final",
     "method": "derived",
     "metric": "winter_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    }
   ],
   "generator_id": "12",
   "id": "generator:eia:3075:12",
   "is_storage": false,
   "operator": {
    "entity_type": "F",
    "entity_type_label": "Federally-owned utility",
    "id": "org:eia:19400",
    "name": "U.S. Army Corps of Engineers, Northwestern Division"
   },
   "ownership": {
    "basis": "eia860_schedule4_default",
    "invalid_shares": false,
    "note": null,
    "shares": [
     {
      "basis": "eia860_schedule4_default",
      "evidence": "reported",
      "fraction": 1.0,
      "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=12; ownership_code=S; rule=eia860_schedule4_default",
      "method": "derived",
      "owned_mw": 66.5,
      "owner": {
       "entity_type": "F",
       "entity_type_label": "Federally-owned utility",
       "id": "org:eia:19400",
       "name": "U.S. Army Corps of Engineers, Northwestern Division"
      },
      "reason": "eia860_schedule4_default",
      "source_ref": "pudl-generators"
     }
    ],
    "unassigned_fraction": 0.0,
    "unassigned_mw": 0.0,
    "unknown_reason": null
   },
   "prime_mover": {
    "code": "HY",
    "label": "hydraulic_turbine"
   },
   "resource_group": "hydro",
   "status": {
    "category": "existing",
    "code": "OP",
    "label": "operating"
   },
   "storage": null,
   "technology": "Conventional Hydroelectric"
  },
  {
   "dates": {
    "note": "EIA-860 reports month and year; day is a placeholder",
    "operating": "1982-10-01",
    "original_planned_operating": null,
    "planned_operating": null,
    "planned_retirement": null,
    "precision": "month",
    "retirement": null
   },
   "energy_source": {
    "code": "WAT",
    "fuel_group": "hydro",
    "label": "water"
   },
   "facts": [
    {
     "basis": "Generator nameplate capacity as reported on EIA-860",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:13#capacity_mw@2024",
     "label": "Nameplate capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=13",
     "maturity": "final",
     "method": "derived",
     "metric": "capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    },
    {
     "basis": "Reported or source-estimated net summer capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:13#summer_capacity_mw@2024",
     "label": "Net summer capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=13",
     "maturity": "final",
     "method": "derived",
     "metric": "summer_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    },
    {
     "basis": "Reported or source-estimated net winter capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:13#winter_capacity_mw@2024",
     "label": "Net winter capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=13",
     "maturity": "final",
     "method": "derived",
     "metric": "winter_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    }
   ],
   "generator_id": "13",
   "id": "generator:eia:3075:13",
   "is_storage": false,
   "operator": {
    "entity_type": "F",
    "entity_type_label": "Federally-owned utility",
    "id": "org:eia:19400",
    "name": "U.S. Army Corps of Engineers, Northwestern Division"
   },
   "ownership": {
    "basis": "eia860_schedule4_default",
    "invalid_shares": false,
    "note": null,
    "shares": [
     {
      "basis": "eia860_schedule4_default",
      "evidence": "reported",
      "fraction": 1.0,
      "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=13; ownership_code=S; rule=eia860_schedule4_default",
      "method": "derived",
      "owned_mw": 66.5,
      "owner": {
       "entity_type": "F",
       "entity_type_label": "Federally-owned utility",
       "id": "org:eia:19400",
       "name": "U.S. Army Corps of Engineers, Northwestern Division"
      },
      "reason": "eia860_schedule4_default",
      "source_ref": "pudl-generators"
     }
    ],
    "unassigned_fraction": 0.0,
    "unassigned_mw": 0.0,
    "unknown_reason": null
   },
   "prime_mover": {
    "code": "HY",
    "label": "hydraulic_turbine"
   },
   "resource_group": "hydro",
   "status": {
    "category": "existing",
    "code": "OP",
    "label": "operating"
   },
   "storage": null,
   "technology": "Conventional Hydroelectric"
  },
  {
   "dates": {
    "note": "EIA-860 reports month and year; day is a placeholder",
    "operating": "1982-06-01",
    "original_planned_operating": null,
    "planned_operating": null,
    "planned_retirement": null,
    "precision": "month",
    "retirement": null
   },
   "energy_source": {
    "code": "WAT",
    "fuel_group": "hydro",
    "label": "water"
   },
   "facts": [
    {
     "basis": "Generator nameplate capacity as reported on EIA-860",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:14#capacity_mw@2024",
     "label": "Nameplate capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=14",
     "maturity": "final",
     "method": "derived",
     "metric": "capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    },
    {
     "basis": "Reported or source-estimated net summer capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:14#summer_capacity_mw@2024",
     "label": "Net summer capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=14",
     "maturity": "final",
     "method": "derived",
     "metric": "summer_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    },
    {
     "basis": "Reported or source-estimated net winter capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:14#winter_capacity_mw@2024",
     "label": "Net winter capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=14",
     "maturity": "final",
     "method": "derived",
     "metric": "winter_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    }
   ],
   "generator_id": "14",
   "id": "generator:eia:3075:14",
   "is_storage": false,
   "operator": {
    "entity_type": "F",
    "entity_type_label": "Federally-owned utility",
    "id": "org:eia:19400",
    "name": "U.S. Army Corps of Engineers, Northwestern Division"
   },
   "ownership": {
    "basis": "eia860_schedule4_default",
    "invalid_shares": false,
    "note": null,
    "shares": [
     {
      "basis": "eia860_schedule4_default",
      "evidence": "reported",
      "fraction": 1.0,
      "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=14; ownership_code=S; rule=eia860_schedule4_default",
      "method": "derived",
      "owned_mw": 66.5,
      "owner": {
       "entity_type": "F",
       "entity_type_label": "Federally-owned utility",
       "id": "org:eia:19400",
       "name": "U.S. Army Corps of Engineers, Northwestern Division"
      },
      "reason": "eia860_schedule4_default",
      "source_ref": "pudl-generators"
     }
    ],
    "unassigned_fraction": 0.0,
    "unassigned_mw": 0.0,
    "unknown_reason": null
   },
   "prime_mover": {
    "code": "HY",
    "label": "hydraulic_turbine"
   },
   "resource_group": "hydro",
   "status": {
    "category": "existing",
    "code": "OP",
    "label": "operating"
   },
   "storage": null,
   "technology": "Conventional Hydroelectric"
  },
  {
   "dates": {
    "note": "EIA-860 reports month and year; day is a placeholder",
    "operating": "1982-03-01",
    "original_planned_operating": null,
    "planned_operating": null,
    "planned_retirement": null,
    "precision": "month",
    "retirement": null
   },
   "energy_source": {
    "code": "WAT",
    "fuel_group": "hydro",
    "label": "water"
   },
   "facts": [
    {
     "basis": "Generator nameplate capacity as reported on EIA-860",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:15#capacity_mw@2024",
     "label": "Nameplate capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=15",
     "maturity": "final",
     "method": "derived",
     "metric": "capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    },
    {
     "basis": "Reported or source-estimated net summer capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:15#summer_capacity_mw@2024",
     "label": "Net summer capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=15",
     "maturity": "final",
     "method": "derived",
     "metric": "summer_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    },
    {
     "basis": "Reported or source-estimated net winter capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:15#winter_capacity_mw@2024",
     "label": "Net winter capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=15",
     "maturity": "final",
     "method": "derived",
     "metric": "winter_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    }
   ],
   "generator_id": "15",
   "id": "generator:eia:3075:15",
   "is_storage": false,
   "operator": {
    "entity_type": "F",
    "entity_type_label": "Federally-owned utility",
    "id": "org:eia:19400",
    "name": "U.S. Army Corps of Engineers, Northwestern Division"
   },
   "ownership": {
    "basis": "eia860_schedule4_default",
    "invalid_shares": false,
    "note": null,
    "shares": [
     {
      "basis": "eia860_schedule4_default",
      "evidence": "reported",
      "fraction": 1.0,
      "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=15; ownership_code=S; rule=eia860_schedule4_default",
      "method": "derived",
      "owned_mw": 66.5,
      "owner": {
       "entity_type": "F",
       "entity_type_label": "Federally-owned utility",
       "id": "org:eia:19400",
       "name": "U.S. Army Corps of Engineers, Northwestern Division"
      },
      "reason": "eia860_schedule4_default",
      "source_ref": "pudl-generators"
     }
    ],
    "unassigned_fraction": 0.0,
    "unassigned_mw": 0.0,
    "unknown_reason": null
   },
   "prime_mover": {
    "code": "HY",
    "label": "hydraulic_turbine"
   },
   "resource_group": "hydro",
   "status": {
    "category": "existing",
    "code": "OP",
    "label": "operating"
   },
   "storage": null,
   "technology": "Conventional Hydroelectric"
  },
  {
   "dates": {
    "note": "EIA-860 reports month and year; day is a placeholder",
    "operating": "1981-12-01",
    "original_planned_operating": null,
    "planned_operating": null,
    "planned_retirement": null,
    "precision": "month",
    "retirement": null
   },
   "energy_source": {
    "code": "WAT",
    "fuel_group": "hydro",
    "label": "water"
   },
   "facts": [
    {
     "basis": "Generator nameplate capacity as reported on EIA-860",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:16#capacity_mw@2024",
     "label": "Nameplate capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=16",
     "maturity": "final",
     "method": "derived",
     "metric": "capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    },
    {
     "basis": "Reported or source-estimated net summer capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:16#summer_capacity_mw@2024",
     "label": "Net summer capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=16",
     "maturity": "final",
     "method": "derived",
     "metric": "summer_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    },
    {
     "basis": "Reported or source-estimated net winter capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:16#winter_capacity_mw@2024",
     "label": "Net winter capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=16",
     "maturity": "final",
     "method": "derived",
     "metric": "winter_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    }
   ],
   "generator_id": "16",
   "id": "generator:eia:3075:16",
   "is_storage": false,
   "operator": {
    "entity_type": "F",
    "entity_type_label": "Federally-owned utility",
    "id": "org:eia:19400",
    "name": "U.S. Army Corps of Engineers, Northwestern Division"
   },
   "ownership": {
    "basis": "eia860_schedule4_default",
    "invalid_shares": false,
    "note": null,
    "shares": [
     {
      "basis": "eia860_schedule4_default",
      "evidence": "reported",
      "fraction": 1.0,
      "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=16; ownership_code=S; rule=eia860_schedule4_default",
      "method": "derived",
      "owned_mw": 66.5,
      "owner": {
       "entity_type": "F",
       "entity_type_label": "Federally-owned utility",
       "id": "org:eia:19400",
       "name": "U.S. Army Corps of Engineers, Northwestern Division"
      },
      "reason": "eia860_schedule4_default",
      "source_ref": "pudl-generators"
     }
    ],
    "unassigned_fraction": 0.0,
    "unassigned_mw": 0.0,
    "unknown_reason": null
   },
   "prime_mover": {
    "code": "HY",
    "label": "hydraulic_turbine"
   },
   "resource_group": "hydro",
   "status": {
    "category": "existing",
    "code": "OP",
    "label": "operating"
   },
   "storage": null,
   "technology": "Conventional Hydroelectric"
  },
  {
   "dates": {
    "note": "EIA-860 reports month and year; day is a placeholder",
    "operating": "1981-09-01",
    "original_planned_operating": null,
    "planned_operating": null,
    "planned_retirement": null,
    "precision": "month",
    "retirement": null
   },
   "energy_source": {
    "code": "WAT",
    "fuel_group": "hydro",
    "label": "water"
   },
   "facts": [
    {
     "basis": "Generator nameplate capacity as reported on EIA-860",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:17#capacity_mw@2024",
     "label": "Nameplate capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=17",
     "maturity": "final",
     "method": "derived",
     "metric": "capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    },
    {
     "basis": "Reported or source-estimated net summer capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:17#summer_capacity_mw@2024",
     "label": "Net summer capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=17",
     "maturity": "final",
     "method": "derived",
     "metric": "summer_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    },
    {
     "basis": "Reported or source-estimated net winter capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:17#winter_capacity_mw@2024",
     "label": "Net winter capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=17",
     "maturity": "final",
     "method": "derived",
     "metric": "winter_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    }
   ],
   "generator_id": "17",
   "id": "generator:eia:3075:17",
   "is_storage": false,
   "operator": {
    "entity_type": "F",
    "entity_type_label": "Federally-owned utility",
    "id": "org:eia:19400",
    "name": "U.S. Army Corps of Engineers, Northwestern Division"
   },
   "ownership": {
    "basis": "eia860_schedule4_default",
    "invalid_shares": false,
    "note": null,
    "shares": [
     {
      "basis": "eia860_schedule4_default",
      "evidence": "reported",
      "fraction": 1.0,
      "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=17; ownership_code=S; rule=eia860_schedule4_default",
      "method": "derived",
      "owned_mw": 66.5,
      "owner": {
       "entity_type": "F",
       "entity_type_label": "Federally-owned utility",
       "id": "org:eia:19400",
       "name": "U.S. Army Corps of Engineers, Northwestern Division"
      },
      "reason": "eia860_schedule4_default",
      "source_ref": "pudl-generators"
     }
    ],
    "unassigned_fraction": 0.0,
    "unassigned_mw": 0.0,
    "unknown_reason": null
   },
   "prime_mover": {
    "code": "HY",
    "label": "hydraulic_turbine"
   },
   "resource_group": "hydro",
   "status": {
    "category": "existing",
    "code": "OP",
    "label": "operating"
   },
   "storage": null,
   "technology": "Conventional Hydroelectric"
  },
  {
   "dates": {
    "note": "EIA-860 reports month and year; day is a placeholder",
    "operating": "1981-05-01",
    "original_planned_operating": null,
    "planned_operating": null,
    "planned_retirement": null,
    "precision": "month",
    "retirement": null
   },
   "energy_source": {
    "code": "WAT",
    "fuel_group": "hydro",
    "label": "water"
   },
   "facts": [
    {
     "basis": "Generator nameplate capacity as reported on EIA-860",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:18#capacity_mw@2024",
     "label": "Nameplate capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=18",
     "maturity": "final",
     "method": "derived",
     "metric": "capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    },
    {
     "basis": "Reported or source-estimated net summer capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:18#summer_capacity_mw@2024",
     "label": "Net summer capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=18",
     "maturity": "final",
     "method": "derived",
     "metric": "summer_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    },
    {
     "basis": "Reported or source-estimated net winter capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:18#winter_capacity_mw@2024",
     "label": "Net winter capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=18",
     "maturity": "final",
     "method": "derived",
     "metric": "winter_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 66.5
    }
   ],
   "generator_id": "18",
   "id": "generator:eia:3075:18",
   "is_storage": false,
   "operator": {
    "entity_type": "F",
    "entity_type_label": "Federally-owned utility",
    "id": "org:eia:19400",
    "name": "U.S. Army Corps of Engineers, Northwestern Division"
   },
   "ownership": {
    "basis": "eia860_schedule4_default",
    "invalid_shares": false,
    "note": null,
    "shares": [
     {
      "basis": "eia860_schedule4_default",
      "evidence": "reported",
      "fraction": 1.0,
      "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=18; ownership_code=S; rule=eia860_schedule4_default",
      "method": "derived",
      "owned_mw": 66.5,
      "owner": {
       "entity_type": "F",
       "entity_type_label": "Federally-owned utility",
       "id": "org:eia:19400",
       "name": "U.S. Army Corps of Engineers, Northwestern Division"
      },
      "reason": "eia860_schedule4_default",
      "source_ref": "pudl-generators"
     }
    ],
    "unassigned_fraction": 0.0,
    "unassigned_mw": 0.0,
    "unknown_reason": null
   },
   "prime_mover": {
    "code": "HY",
    "label": "hydraulic_turbine"
   },
   "resource_group": "hydro",
   "status": {
    "category": "existing",
    "code": "OA",
    "label": "out_of_service_short_term"
   },
   "storage": null,
   "technology": "Conventional Hydroelectric"
  },
  {
   "dates": {
    "note": "EIA-860 reports month and year; day is a placeholder",
    "operating": "1938-08-01",
    "original_planned_operating": null,
    "planned_operating": null,
    "planned_retirement": null,
    "precision": "month",
    "retirement": null
   },
   "energy_source": {
    "code": "WAT",
    "fuel_group": "hydro",
    "label": "water"
   },
   "facts": [
    {
     "basis": "Generator nameplate capacity as reported on EIA-860",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:2#capacity_mw@2024",
     "label": "Nameplate capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=2",
     "maturity": "final",
     "method": "derived",
     "metric": "capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 53.5
    },
    {
     "basis": "Reported or source-estimated net summer capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:2#summer_capacity_mw@2024",
     "label": "Net summer capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=2",
     "maturity": "final",
     "method": "derived",
     "metric": "summer_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 53.5
    },
    {
     "basis": "Reported or source-estimated net winter capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:2#winter_capacity_mw@2024",
     "label": "Net winter capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=2",
     "maturity": "final",
     "method": "derived",
     "metric": "winter_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 53.5
    }
   ],
   "generator_id": "2",
   "id": "generator:eia:3075:2",
   "is_storage": false,
   "operator": {
    "entity_type": "F",
    "entity_type_label": "Federally-owned utility",
    "id": "org:eia:19400",
    "name": "U.S. Army Corps of Engineers, Northwestern Division"
   },
   "ownership": {
    "basis": "eia860_schedule4_default",
    "invalid_shares": false,
    "note": null,
    "shares": [
     {
      "basis": "eia860_schedule4_default",
      "evidence": "reported",
      "fraction": 1.0,
      "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=2; ownership_code=S; rule=eia860_schedule4_default",
      "method": "derived",
      "owned_mw": 53.5,
      "owner": {
       "entity_type": "F",
       "entity_type_label": "Federally-owned utility",
       "id": "org:eia:19400",
       "name": "U.S. Army Corps of Engineers, Northwestern Division"
      },
      "reason": "eia860_schedule4_default",
      "source_ref": "pudl-generators"
     }
    ],
    "unassigned_fraction": 0.0,
    "unassigned_mw": 0.0,
    "unknown_reason": null
   },
   "prime_mover": {
    "code": "HY",
    "label": "hydraulic_turbine"
   },
   "resource_group": "hydro",
   "status": {
    "category": "existing",
    "code": "OA",
    "label": "out_of_service_short_term"
   },
   "storage": null,
   "technology": "Conventional Hydroelectric"
  },
  {
   "dates": {
    "note": "EIA-860 reports month and year; day is a placeholder",
    "operating": "1941-01-01",
    "original_planned_operating": null,
    "planned_operating": null,
    "planned_retirement": null,
    "precision": "month",
    "retirement": null
   },
   "energy_source": {
    "code": "WAT",
    "fuel_group": "hydro",
    "label": "water"
   },
   "facts": [
    {
     "basis": "Generator nameplate capacity as reported on EIA-860",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:3#capacity_mw@2024",
     "label": "Nameplate capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=3",
     "maturity": "final",
     "method": "derived",
     "metric": "capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 62.1
    },
    {
     "basis": "Reported or source-estimated net summer capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:3#summer_capacity_mw@2024",
     "label": "Net summer capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=3",
     "maturity": "final",
     "method": "derived",
     "metric": "summer_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 62.1
    },
    {
     "basis": "Reported or source-estimated net winter capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:3#winter_capacity_mw@2024",
     "label": "Net winter capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=3",
     "maturity": "final",
     "method": "derived",
     "metric": "winter_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 62.1
    }
   ],
   "generator_id": "3",
   "id": "generator:eia:3075:3",
   "is_storage": false,
   "operator": {
    "entity_type": "F",
    "entity_type_label": "Federally-owned utility",
    "id": "org:eia:19400",
    "name": "U.S. Army Corps of Engineers, Northwestern Division"
   },
   "ownership": {
    "basis": "eia860_schedule4_default",
    "invalid_shares": false,
    "note": null,
    "shares": [
     {
      "basis": "eia860_schedule4_default",
      "evidence": "reported",
      "fraction": 1.0,
      "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=3; ownership_code=S; rule=eia860_schedule4_default",
      "method": "derived",
      "owned_mw": 62.1,
      "owner": {
       "entity_type": "F",
       "entity_type_label": "Federally-owned utility",
       "id": "org:eia:19400",
       "name": "U.S. Army Corps of Engineers, Northwestern Division"
      },
      "reason": "eia860_schedule4_default",
      "source_ref": "pudl-generators"
     }
    ],
    "unassigned_fraction": 0.0,
    "unassigned_mw": 0.0,
    "unknown_reason": null
   },
   "prime_mover": {
    "code": "HY",
    "label": "hydraulic_turbine"
   },
   "resource_group": "hydro",
   "status": {
    "category": "existing",
    "code": "OP",
    "label": "operating"
   },
   "storage": null,
   "technology": "Conventional Hydroelectric"
  },
  {
   "dates": {
    "note": "EIA-860 reports month and year; day is a placeholder",
    "operating": "1941-02-01",
    "original_planned_operating": null,
    "planned_operating": null,
    "planned_retirement": null,
    "precision": "month",
    "retirement": null
   },
   "energy_source": {
    "code": "WAT",
    "fuel_group": "hydro",
    "label": "water"
   },
   "facts": [
    {
     "basis": "Generator nameplate capacity as reported on EIA-860",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:4#capacity_mw@2024",
     "label": "Nameplate capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=4",
     "maturity": "final",
     "method": "derived",
     "metric": "capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 62.1
    },
    {
     "basis": "Reported or source-estimated net summer capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:4#summer_capacity_mw@2024",
     "label": "Net summer capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=4",
     "maturity": "final",
     "method": "derived",
     "metric": "summer_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 62.1
    },
    {
     "basis": "Reported or source-estimated net winter capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:4#winter_capacity_mw@2024",
     "label": "Net winter capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=4",
     "maturity": "final",
     "method": "derived",
     "metric": "winter_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 62.1
    }
   ],
   "generator_id": "4",
   "id": "generator:eia:3075:4",
   "is_storage": false,
   "operator": {
    "entity_type": "F",
    "entity_type_label": "Federally-owned utility",
    "id": "org:eia:19400",
    "name": "U.S. Army Corps of Engineers, Northwestern Division"
   },
   "ownership": {
    "basis": "eia860_schedule4_default",
    "invalid_shares": false,
    "note": null,
    "shares": [
     {
      "basis": "eia860_schedule4_default",
      "evidence": "reported",
      "fraction": 1.0,
      "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=4; ownership_code=S; rule=eia860_schedule4_default",
      "method": "derived",
      "owned_mw": 62.1,
      "owner": {
       "entity_type": "F",
       "entity_type_label": "Federally-owned utility",
       "id": "org:eia:19400",
       "name": "U.S. Army Corps of Engineers, Northwestern Division"
      },
      "reason": "eia860_schedule4_default",
      "source_ref": "pudl-generators"
     }
    ],
    "unassigned_fraction": 0.0,
    "unassigned_mw": 0.0,
    "unknown_reason": null
   },
   "prime_mover": {
    "code": "HY",
    "label": "hydraulic_turbine"
   },
   "resource_group": "hydro",
   "status": {
    "category": "existing",
    "code": "OP",
    "label": "operating"
   },
   "storage": null,
   "technology": "Conventional Hydroelectric"
  },
  {
   "dates": {
    "note": "EIA-860 reports month and year; day is a placeholder",
    "operating": "1941-10-01",
    "original_planned_operating": null,
    "planned_operating": null,
    "planned_retirement": null,
    "precision": "month",
    "retirement": null
   },
   "energy_source": {
    "code": "WAT",
    "fuel_group": "hydro",
    "label": "water"
   },
   "facts": [
    {
     "basis": "Generator nameplate capacity as reported on EIA-860",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:5#capacity_mw@2024",
     "label": "Nameplate capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=5",
     "maturity": "final",
     "method": "derived",
     "metric": "capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 62.1
    },
    {
     "basis": "Reported or source-estimated net summer capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:5#summer_capacity_mw@2024",
     "label": "Net summer capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=5",
     "maturity": "final",
     "method": "derived",
     "metric": "summer_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 62.1
    },
    {
     "basis": "Reported or source-estimated net winter capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:5#winter_capacity_mw@2024",
     "label": "Net winter capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=5",
     "maturity": "final",
     "method": "derived",
     "metric": "winter_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 62.1
    }
   ],
   "generator_id": "5",
   "id": "generator:eia:3075:5",
   "is_storage": false,
   "operator": {
    "entity_type": "F",
    "entity_type_label": "Federally-owned utility",
    "id": "org:eia:19400",
    "name": "U.S. Army Corps of Engineers, Northwestern Division"
   },
   "ownership": {
    "basis": "eia860_schedule4_default",
    "invalid_shares": false,
    "note": null,
    "shares": [
     {
      "basis": "eia860_schedule4_default",
      "evidence": "reported",
      "fraction": 1.0,
      "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=5; ownership_code=S; rule=eia860_schedule4_default",
      "method": "derived",
      "owned_mw": 62.1,
      "owner": {
       "entity_type": "F",
       "entity_type_label": "Federally-owned utility",
       "id": "org:eia:19400",
       "name": "U.S. Army Corps of Engineers, Northwestern Division"
      },
      "reason": "eia860_schedule4_default",
      "source_ref": "pudl-generators"
     }
    ],
    "unassigned_fraction": 0.0,
    "unassigned_mw": 0.0,
    "unknown_reason": null
   },
   "prime_mover": {
    "code": "HY",
    "label": "hydraulic_turbine"
   },
   "resource_group": "hydro",
   "status": {
    "category": "existing",
    "code": "OA",
    "label": "out_of_service_short_term"
   },
   "storage": null,
   "technology": "Conventional Hydroelectric"
  },
  {
   "dates": {
    "note": "EIA-860 reports month and year; day is a placeholder",
    "operating": "1942-06-01",
    "original_planned_operating": null,
    "planned_operating": null,
    "planned_retirement": null,
    "precision": "month",
    "retirement": null
   },
   "energy_source": {
    "code": "WAT",
    "fuel_group": "hydro",
    "label": "water"
   },
   "facts": [
    {
     "basis": "Generator nameplate capacity as reported on EIA-860",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:6#capacity_mw@2024",
     "label": "Nameplate capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=6",
     "maturity": "final",
     "method": "derived",
     "metric": "capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 62.1
    },
    {
     "basis": "Reported or source-estimated net summer capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:6#summer_capacity_mw@2024",
     "label": "Net summer capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=6",
     "maturity": "final",
     "method": "derived",
     "metric": "summer_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 62.1
    },
    {
     "basis": "Reported or source-estimated net winter capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:6#winter_capacity_mw@2024",
     "label": "Net winter capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=6",
     "maturity": "final",
     "method": "derived",
     "metric": "winter_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 62.1
    }
   ],
   "generator_id": "6",
   "id": "generator:eia:3075:6",
   "is_storage": false,
   "operator": {
    "entity_type": "F",
    "entity_type_label": "Federally-owned utility",
    "id": "org:eia:19400",
    "name": "U.S. Army Corps of Engineers, Northwestern Division"
   },
   "ownership": {
    "basis": "eia860_schedule4_default",
    "invalid_shares": false,
    "note": null,
    "shares": [
     {
      "basis": "eia860_schedule4_default",
      "evidence": "reported",
      "fraction": 1.0,
      "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=6; ownership_code=S; rule=eia860_schedule4_default",
      "method": "derived",
      "owned_mw": 62.1,
      "owner": {
       "entity_type": "F",
       "entity_type_label": "Federally-owned utility",
       "id": "org:eia:19400",
       "name": "U.S. Army Corps of Engineers, Northwestern Division"
      },
      "reason": "eia860_schedule4_default",
      "source_ref": "pudl-generators"
     }
    ],
    "unassigned_fraction": 0.0,
    "unassigned_mw": 0.0,
    "unknown_reason": null
   },
   "prime_mover": {
    "code": "HY",
    "label": "hydraulic_turbine"
   },
   "resource_group": "hydro",
   "status": {
    "category": "existing",
    "code": "OA",
    "label": "out_of_service_short_term"
   },
   "storage": null,
   "technology": "Conventional Hydroelectric"
  },
  {
   "dates": {
    "note": "EIA-860 reports month and year; day is a placeholder",
    "operating": "1943-04-01",
    "original_planned_operating": null,
    "planned_operating": null,
    "planned_retirement": null,
    "precision": "month",
    "retirement": null
   },
   "energy_source": {
    "code": "WAT",
    "fuel_group": "hydro",
    "label": "water"
   },
   "facts": [
    {
     "basis": "Generator nameplate capacity as reported on EIA-860",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:7#capacity_mw@2024",
     "label": "Nameplate capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=7",
     "maturity": "final",
     "method": "derived",
     "metric": "capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 62.1
    },
    {
     "basis": "Reported or source-estimated net summer capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:7#summer_capacity_mw@2024",
     "label": "Net summer capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=7",
     "maturity": "final",
     "method": "derived",
     "metric": "summer_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 62.1
    },
    {
     "basis": "Reported or source-estimated net winter capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:7#winter_capacity_mw@2024",
     "label": "Net winter capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=7",
     "maturity": "final",
     "method": "derived",
     "metric": "winter_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 62.1
    }
   ],
   "generator_id": "7",
   "id": "generator:eia:3075:7",
   "is_storage": false,
   "operator": {
    "entity_type": "F",
    "entity_type_label": "Federally-owned utility",
    "id": "org:eia:19400",
    "name": "U.S. Army Corps of Engineers, Northwestern Division"
   },
   "ownership": {
    "basis": "eia860_schedule4_default",
    "invalid_shares": false,
    "note": null,
    "shares": [
     {
      "basis": "eia860_schedule4_default",
      "evidence": "reported",
      "fraction": 1.0,
      "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=7; ownership_code=S; rule=eia860_schedule4_default",
      "method": "derived",
      "owned_mw": 62.1,
      "owner": {
       "entity_type": "F",
       "entity_type_label": "Federally-owned utility",
       "id": "org:eia:19400",
       "name": "U.S. Army Corps of Engineers, Northwestern Division"
      },
      "reason": "eia860_schedule4_default",
      "source_ref": "pudl-generators"
     }
    ],
    "unassigned_fraction": 0.0,
    "unassigned_mw": 0.0,
    "unknown_reason": null
   },
   "prime_mover": {
    "code": "HY",
    "label": "hydraulic_turbine"
   },
   "resource_group": "hydro",
   "status": {
    "category": "existing",
    "code": "OA",
    "label": "out_of_service_short_term"
   },
   "storage": null,
   "technology": "Conventional Hydroelectric"
  },
  {
   "dates": {
    "note": "EIA-860 reports month and year; day is a placeholder",
    "operating": "1943-07-01",
    "original_planned_operating": null,
    "planned_operating": null,
    "planned_retirement": null,
    "precision": "month",
    "retirement": null
   },
   "energy_source": {
    "code": "WAT",
    "fuel_group": "hydro",
    "label": "water"
   },
   "facts": [
    {
     "basis": "Generator nameplate capacity as reported on EIA-860",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:8#capacity_mw@2024",
     "label": "Nameplate capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=8",
     "maturity": "final",
     "method": "derived",
     "metric": "capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 62.1
    },
    {
     "basis": "Reported or source-estimated net summer capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:8#summer_capacity_mw@2024",
     "label": "Net summer capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=8",
     "maturity": "final",
     "method": "derived",
     "metric": "summer_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 62.1
    },
    {
     "basis": "Reported or source-estimated net winter capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:8#winter_capacity_mw@2024",
     "label": "Net winter capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=8",
     "maturity": "final",
     "method": "derived",
     "metric": "winter_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 62.1
    }
   ],
   "generator_id": "8",
   "id": "generator:eia:3075:8",
   "is_storage": false,
   "operator": {
    "entity_type": "F",
    "entity_type_label": "Federally-owned utility",
    "id": "org:eia:19400",
    "name": "U.S. Army Corps of Engineers, Northwestern Division"
   },
   "ownership": {
    "basis": "eia860_schedule4_default",
    "invalid_shares": false,
    "note": null,
    "shares": [
     {
      "basis": "eia860_schedule4_default",
      "evidence": "reported",
      "fraction": 1.0,
      "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=8; ownership_code=S; rule=eia860_schedule4_default",
      "method": "derived",
      "owned_mw": 62.1,
      "owner": {
       "entity_type": "F",
       "entity_type_label": "Federally-owned utility",
       "id": "org:eia:19400",
       "name": "U.S. Army Corps of Engineers, Northwestern Division"
      },
      "reason": "eia860_schedule4_default",
      "source_ref": "pudl-generators"
     }
    ],
    "unassigned_fraction": 0.0,
    "unassigned_mw": 0.0,
    "unknown_reason": null
   },
   "prime_mover": {
    "code": "HY",
    "label": "hydraulic_turbine"
   },
   "resource_group": "hydro",
   "status": {
    "category": "existing",
    "code": "OA",
    "label": "out_of_service_short_term"
   },
   "storage": null,
   "technology": "Conventional Hydroelectric"
  },
  {
   "dates": {
    "note": "EIA-860 reports month and year; day is a placeholder",
    "operating": "1943-10-01",
    "original_planned_operating": null,
    "planned_operating": null,
    "planned_retirement": null,
    "precision": "month",
    "retirement": null
   },
   "energy_source": {
    "code": "WAT",
    "fuel_group": "hydro",
    "label": "water"
   },
   "facts": [
    {
     "basis": "Generator nameplate capacity as reported on EIA-860",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:9#capacity_mw@2024",
     "label": "Nameplate capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=9",
     "maturity": "final",
     "method": "derived",
     "metric": "capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 62.1
    },
    {
     "basis": "Reported or source-estimated net summer capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:9#summer_capacity_mw@2024",
     "label": "Net summer capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=9",
     "maturity": "final",
     "method": "derived",
     "metric": "summer_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 62.1
    },
    {
     "basis": "Reported or source-estimated net winter capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:9#winter_capacity_mw@2024",
     "label": "Net winter capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=9",
     "maturity": "final",
     "method": "derived",
     "metric": "winter_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 62.1
    }
   ],
   "generator_id": "9",
   "id": "generator:eia:3075:9",
   "is_storage": false,
   "operator": {
    "entity_type": "F",
    "entity_type_label": "Federally-owned utility",
    "id": "org:eia:19400",
    "name": "U.S. Army Corps of Engineers, Northwestern Division"
   },
   "ownership": {
    "basis": "eia860_schedule4_default",
    "invalid_shares": false,
    "note": null,
    "shares": [
     {
      "basis": "eia860_schedule4_default",
      "evidence": "reported",
      "fraction": 1.0,
      "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=9; ownership_code=S; rule=eia860_schedule4_default",
      "method": "derived",
      "owned_mw": 62.1,
      "owner": {
       "entity_type": "F",
       "entity_type_label": "Federally-owned utility",
       "id": "org:eia:19400",
       "name": "U.S. Army Corps of Engineers, Northwestern Division"
      },
      "reason": "eia860_schedule4_default",
      "source_ref": "pudl-generators"
     }
    ],
    "unassigned_fraction": 0.0,
    "unassigned_mw": 0.0,
    "unknown_reason": null
   },
   "prime_mover": {
    "code": "HY",
    "label": "hydraulic_turbine"
   },
   "resource_group": "hydro",
   "status": {
    "category": "existing",
    "code": "OA",
    "label": "out_of_service_short_term"
   },
   "storage": null,
   "technology": "Conventional Hydroelectric"
  },
  {
   "dates": {
    "note": "EIA-860 reports month and year; day is a placeholder",
    "operating": "1982-01-01",
    "original_planned_operating": null,
    "planned_operating": null,
    "planned_retirement": null,
    "precision": "month",
    "retirement": null
   },
   "energy_source": {
    "code": "WAT",
    "fuel_group": "hydro",
    "label": "water"
   },
   "facts": [
    {
     "basis": "Generator nameplate capacity as reported on EIA-860",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:F1#capacity_mw@2024",
     "label": "Nameplate capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=F1",
     "maturity": "final",
     "method": "derived",
     "metric": "capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 13.1
    },
    {
     "basis": "Reported or source-estimated net summer capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:F1#summer_capacity_mw@2024",
     "label": "Net summer capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=F1",
     "maturity": "final",
     "method": "derived",
     "metric": "summer_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 13.1
    },
    {
     "basis": "Reported or source-estimated net winter capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:F1#winter_capacity_mw@2024",
     "label": "Net winter capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=F1",
     "maturity": "final",
     "method": "derived",
     "metric": "winter_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 13.1
    }
   ],
   "generator_id": "F1",
   "id": "generator:eia:3075:F1",
   "is_storage": false,
   "operator": {
    "entity_type": "F",
    "entity_type_label": "Federally-owned utility",
    "id": "org:eia:19400",
    "name": "U.S. Army Corps of Engineers, Northwestern Division"
   },
   "ownership": {
    "basis": "eia860_schedule4_default",
    "invalid_shares": false,
    "note": null,
    "shares": [
     {
      "basis": "eia860_schedule4_default",
      "evidence": "reported",
      "fraction": 1.0,
      "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=F1; ownership_code=S; rule=eia860_schedule4_default",
      "method": "derived",
      "owned_mw": 13.1,
      "owner": {
       "entity_type": "F",
       "entity_type_label": "Federally-owned utility",
       "id": "org:eia:19400",
       "name": "U.S. Army Corps of Engineers, Northwestern Division"
      },
      "reason": "eia860_schedule4_default",
      "source_ref": "pudl-generators"
     }
    ],
    "unassigned_fraction": 0.0,
    "unassigned_mw": 0.0,
    "unknown_reason": null
   },
   "prime_mover": {
    "code": "HY",
    "label": "hydraulic_turbine"
   },
   "resource_group": "hydro",
   "status": {
    "category": "existing",
    "code": "OP",
    "label": "operating"
   },
   "storage": null,
   "technology": "Conventional Hydroelectric"
  },
  {
   "dates": {
    "note": "EIA-860 reports month and year; day is a placeholder",
    "operating": "1981-11-01",
    "original_planned_operating": null,
    "planned_operating": null,
    "planned_retirement": null,
    "precision": "month",
    "retirement": null
   },
   "energy_source": {
    "code": "WAT",
    "fuel_group": "hydro",
    "label": "water"
   },
   "facts": [
    {
     "basis": "Generator nameplate capacity as reported on EIA-860",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:F2#capacity_mw@2024",
     "label": "Nameplate capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=F2",
     "maturity": "final",
     "method": "derived",
     "metric": "capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 13.1
    },
    {
     "basis": "Reported or source-estimated net summer capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:F2#summer_capacity_mw@2024",
     "label": "Net summer capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=F2",
     "maturity": "final",
     "method": "derived",
     "metric": "summer_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 13.1
    },
    {
     "basis": "Reported or source-estimated net winter capability",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "generator:eia:3075:F2#winter_capacity_mw@2024",
     "label": "Net winter capacity",
     "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=F2",
     "maturity": "final",
     "method": "derived",
     "metric": "winter_capacity_mw",
     "missing_reason": null,
     "note": null,
     "period": {
      "kind": "inventory_year",
      "note": "EIA-860 annual inventory; status as of the end of the reporting year",
      "report_date": "2024-01-01",
      "year": 2024
     },
     "precision": 1,
     "quality": "valid",
     "source_ref": "pudl-generators",
     "unit": "MW",
     "value": 13.1
    }
   ],
   "generator_id": "F2",
   "id": "generator:eia:3075:F2",
   "is_storage": false,
   "operator": {
    "entity_type": "F",
    "entity_type_label": "Federally-owned utility",
    "id": "org:eia:19400",
    "name": "U.S. Army Corps of Engineers, Northwestern Division"
   },
   "ownership": {
    "basis": "eia860_schedule4_default",
    "invalid_shares": false,
    "note": null,
    "shares": [
     {
      "basis": "eia860_schedule4_default",
      "evidence": "reported",
      "fraction": 1.0,
      "locator": "out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=3075; generator_id=F2; ownership_code=S; rule=eia860_schedule4_default",
      "method": "derived",
      "owned_mw": 13.1,
      "owner": {
       "entity_type": "F",
       "entity_type_label": "Federally-owned utility",
       "id": "org:eia:19400",
       "name": "U.S. Army Corps of Engineers, Northwestern Division"
      },
      "reason": "eia860_schedule4_default",
      "source_ref": "pudl-generators"
     }
    ],
    "unassigned_fraction": 0.0,
    "unassigned_mw": 0.0,
    "unknown_reason": null
   },
   "prime_mover": {
    "code": "HY",
    "label": "hydraulic_turbine"
   },
   "resource_group": "hydro",
   "status": {
    "category": "existing",
    "code": "OA",
    "label": "out_of_service_short_term"
   },
   "storage": null,
   "technology": "Conventional Hydroelectric"
  }
 ],
 "id": "plant:eia:3075",
 "interconnection_requests": [],
 "latest": {
  "changed_on": "2026-08-01",
  "changes_since_baseline": [
   {
    "baseline_capacity_mw": 53.5,
    "baseline_status": "OP",
    "change": "status_changed",
    "changed_on": "2026-08-01",
    "generator_id": "1",
    "latest_capacity_mw": 53.5,
    "latest_status": "OA",
    "planned_operating_date": null,
    "retirement_date": null
   },
   {
    "baseline_capacity_mw": 62.1,
    "baseline_status": "OA",
    "change": "entered_service",
    "changed_on": "2026-08-01",
    "generator_id": "10",
    "latest_capacity_mw": 62.1,
    "latest_status": "OP",
    "planned_operating_date": null,
    "retirement_date": null
   },
   {
    "baseline_capacity_mw": 66.5,
    "baseline_status": "OA",
    "change": "entered_service",
    "changed_on": "2026-08-01",
    "generator_id": "18",
    "latest_capacity_mw": 66.5,
    "latest_status": "OP",
    "planned_operating_date": null,
    "retirement_date": null
   },
   {
    "baseline_capacity_mw": 62.1,
    "baseline_status": "OA",
    "change": "entered_service",
    "changed_on": "2026-08-01",
    "generator_id": "5",
    "latest_capacity_mw": 62.1,
    "latest_status": "OP",
    "planned_operating_date": null,
    "retirement_date": null
   },
   {
    "baseline_capacity_mw": 62.1,
    "baseline_status": "OA",
    "change": "entered_service",
    "changed_on": "2026-08-01",
    "generator_id": "6",
    "latest_capacity_mw": 62.1,
    "latest_status": "OP",
    "planned_operating_date": null,
    "retirement_date": null
   },
   {
    "baseline_capacity_mw": 62.1,
    "baseline_status": "OA",
    "change": "entered_service",
    "changed_on": "2026-08-01",
    "generator_id": "7",
    "latest_capacity_mw": 62.1,
    "latest_status": "OP",
    "planned_operating_date": null,
    "retirement_date": null
   },
   {
    "baseline_capacity_mw": 62.1,
    "baseline_status": "OA",
    "change": "entered_service",
    "changed_on": "2026-08-01",
    "generator_id": "8",
    "latest_capacity_mw": 62.1,
    "latest_status": "OP",
    "planned_operating_date": null,
    "retirement_date": null
   }
  ],
  "edition": {
   "report_month": "2026-08-01",
   "source_ref": "eia860m-inventory",
   "valid_until": "2026-09-01"
  },
  "facts": [
   {
    "basis": "Sum of nameplate MW over generators whose current-valid EIA-860M workbook assertion has status OP; dated by the complete inventory edition; never added to the baseline aggregate",
    "coverage": {
     "eligible": 20,
     "included": 20,
     "unit": "current and historical generators",
     "unknown_current_state": 0
    },
    "denominator": null,
    "evidence": "reported",
    "fact_id": "plant:eia:3075#latest_nameplate_mw_op",
    "label": "Operating nameplate capacity, latest inventory",
    "locator": "Preliminary Monthly Electric Generator Inventory, August 2026; plant_id_eia=3075; report_date=2026-08-01",
    "maturity": "provisional",
    "method": "derived",
    "metric": "latest_nameplate_mw_op",
    "missing_reason": null,
    "note": null,
    "period": {
     "as_of": "2026-08-01",
     "kind": "instant",
     "note": "Complete EIA-860M monthly inventory; assertion dates are not event dates"
    },
    "precision": 1,
    "quality": "valid",
    "source_ref": "eia860m-inventory",
    "unit": "MW",
    "value": 979.8000000000001
   },
   {
    "basis": "Sum of nameplate MW over generators whose current-valid EIA-860M workbook assertion is a proposal or construction stage (P, L, T, U, V, OT, TS); a proposal is not a commitment and its date is a forecast",
    "coverage": {
     "eligible": 20,
     "included": 20,
     "unit": "current and historical generators"
    },
    "denominator": null,
    "evidence": "reported",
    "fact_id": "plant:eia:3075#latest_nameplate_mw_planned",
    "label": "Planned nameplate capacity, latest inventory",
    "locator": "Preliminary Monthly Electric Generator Inventory, August 2026; plant_id_eia=3075; report_date=2026-08-01",
    "maturity": "provisional",
    "method": "derived",
    "metric": "latest_nameplate_mw_planned",
    "missing_reason": "not_applicable",
    "note": null,
    "period": {
     "as_of": "2026-08-01",
     "kind": "instant",
     "note": "Complete EIA-860M monthly inventory; assertion dates are not event dates"
    },
    "precision": 1,
    "quality": "not_applicable",
    "source_ref": "eia860m-inventory",
    "unit": "MW",
    "value": null
   },
   {
    "basis": "Sum of nameplate MW over generators whose current-valid EIA-860M workbook assertion is retired, cancelled or indefinitely postponed (RE, CN, IP); retired is not demolished",
    "coverage": {
     "eligible": 20,
     "included": 20,
     "unit": "current and historical generators"
    },
    "denominator": null,
    "evidence": "reported",
    "fact_id": "plant:eia:3075#latest_nameplate_mw_retired",
    "label": "Retired or cancelled nameplate capacity, latest inventory",
    "locator": "Preliminary Monthly Electric Generator Inventory, August 2026; plant_id_eia=3075; report_date=2026-08-01",
    "maturity": "provisional",
    "method": "derived",
    "metric": "latest_nameplate_mw_retired",
    "missing_reason": "not_applicable",
    "note": null,
    "period": {
     "as_of": "2026-08-01",
     "kind": "instant",
     "note": "Complete EIA-860M monthly inventory; assertion dates are not event dates"
    },
    "precision": 1,
    "quality": "not_applicable",
    "source_ref": "eia860m-inventory",
    "unit": "MW",
    "value": null
   }
  ],
  "historical_units": [],
  "in_baseline": true,
  "last_retirement_date": null,
  "life": "operating",
  "next_planned_operating_date": null,
  "note": "Independently dated by EIA-860M; the baseline facts above stay the validated edition. Planned dates are forecasts; retired is not demolished.",
  "summary": {
   "mw_entered_service": 377.0,
   "mw_retired_or_cancelled": null,
   "units_entered_service": 6,
   "units_new_since_baseline": 0,
   "units_retired_or_cancelled": 0
  },
  "units": [
   {
    "capacity_mw": 53.5,
    "changed_on": "2026-08-01",
    "dates": {
     "operating": "1938-07-01",
     "planned_operating": null,
     "planned_retirement": null,
     "precision": "month",
     "retirement": null
    },
    "generator_id": "1",
    "id": "generator:eia:3075:1",
    "in_baseline": true,
    "life": "standby_or_out_of_service",
    "resource_group": "hydro",
    "status": {
     "category": "existing",
     "code": "OA",
     "label": "out_of_service_short_term"
    },
    "technology": "Conventional Hydroelectric"
   },
   {
    "capacity_mw": 62.1,
    "changed_on": "2026-08-01",
    "dates": {
     "operating": "1944-01-01",
     "planned_operating": null,
     "planned_retirement": null,
     "precision": "month",
     "retirement": null
    },
    "generator_id": "10",
    "id": "generator:eia:3075:10",
    "in_baseline": true,
    "life": "operating",
    "resource_group": "hydro",
    "status": {
     "category": "existing",
     "code": "OP",
     "label": "operating"
    },
    "technology": "Conventional Hydroelectric"
   },
   {
    "capacity_mw": 66.5,
    "changed_on": "2026-08-01",
    "dates": {
     "operating": "1982-10-01",
     "planned_operating": null,
     "planned_retirement": null,
     "precision": "month",
     "retirement": null
    },
    "generator_id": "11",
    "id": "generator:eia:3075:11",
    "in_baseline": true,
    "life": "operating",
    "resource_group": "hydro",
    "status": {
     "category": "existing",
     "code": "OP",
     "label": "operating"
    },
    "technology": "Conventional Hydroelectric"
   },
   {
    "capacity_mw": 66.5,
    "changed_on": "2026-08-01",
    "dates": {
     "operating": "1982-10-01",
     "planned_operating": null,
     "planned_retirement": null,
     "precision": "month",
     "retirement": null
    },
    "generator_id": "12",
    "id": "generator:eia:3075:12",
    "in_baseline": true,
    "life": "operating",
    "resource_group": "hydro",
    "status": {
     "category": "existing",
     "code": "OP",
     "label": "operating"
    },
    "technology": "Conventional Hydroelectric"
   },
   {
    "capacity_mw": 66.5,
    "changed_on": "2026-08-01",
    "dates": {
     "operating": "1982-10-01",
     "planned_operating": null,
     "planned_retirement": null,
     "precision": "month",
     "retirement": null
    },
    "generator_id": "13",
    "id": "generator:eia:3075:13",
    "in_baseline": true,
    "life": "operating",
    "resource_group": "hydro",
    "status": {
     "category": "existing",
     "code": "OP",
     "label": "operating"
    },
    "technology": "Conventional Hydroelectric"
   },
   {
    "capacity_mw": 66.5,
    "changed_on": "2026-08-01",
    "dates": {
     "operating": "1982-06-01",
     "planned_operating": null,
     "planned_retirement": null,
     "precision": "month",
     "retirement": null
    },
    "generator_id": "14",
    "id": "generator:eia:3075:14",
    "in_baseline": true,
    "life": "operating",
    "resource_group": "hydro",
    "status": {
     "category": "existing",
     "code": "OP",
     "label": "operating"
    },
    "technology": "Conventional Hydroelectric"
   },
   {
    "capacity_mw": 66.5,
    "changed_on": "2026-08-01",
    "dates": {
     "operating": "1982-03-01",
     "planned_operating": null,
     "planned_retirement": null,
     "precision": "month",
     "retirement": null
    },
    "generator_id": "15",
    "id": "generator:eia:3075:15",
    "in_baseline": true,
    "life": "operating",
    "resource_group": "hydro",
    "status": {
     "category": "existing",
     "code": "OP",
     "label": "operating"
    },
    "technology": "Conventional Hydroelectric"
   },
   {
    "capacity_mw": 66.5,
    "changed_on": "2026-08-01",
    "dates": {
     "operating": "1981-12-01",
     "planned_operating": null,
     "planned_retirement": null,
     "precision": "month",
     "retirement": null
    },
    "generator_id": "16",
    "id": "generator:eia:3075:16",
    "in_baseline": true,
    "life": "operating",
    "resource_group": "hydro",
    "status": {
     "category": "existing",
     "code": "OP",
     "label": "operating"
    },
    "technology": "Conventional Hydroelectric"
   },
   {
    "capacity_mw": 66.5,
    "changed_on": "2026-08-01",
    "dates": {
     "operating": "1981-09-01",
     "planned_operating": null,
     "planned_retirement": null,
     "precision": "month",
     "retirement": null
    },
    "generator_id": "17",
    "id": "generator:eia:3075:17",
    "in_baseline": true,
    "life": "operating",
    "resource_group": "hydro",
    "status": {
     "category": "existing",
     "code": "OP",
     "label": "operating"
    },
    "technology": "Conventional Hydroelectric"
   },
   {
    "capacity_mw": 66.5,
    "changed_on": "2026-08-01",
    "dates": {
     "operating": "1981-05-01",
     "planned_operating": null,
     "planned_retirement": null,
     "precision": "month",
     "retirement": null
    },
    "generator_id": "18",
    "id": "generator:eia:3075:18",
    "in_baseline": true,
    "life": "operating",
    "resource_group": "hydro",
    "status": {
     "category": "existing",
     "code": "OP",
     "label": "operating"
    },
    "technology": "Conventional Hydroelectric"
   },
   {
    "capacity_mw": 53.5,
    "changed_on": "2026-08-01",
    "dates": {
     "operating": "1938-08-01",
     "planned_operating": null,
     "planned_retirement": null,
     "precision": "month",
     "retirement": null
    },
    "generator_id": "2",
    "id": "generator:eia:3075:2",
    "in_baseline": true,
    "life": "standby_or_out_of_service",
    "resource_group": "hydro",
    "status": {
     "category": "existing",
     "code": "OA",
     "label": "out_of_service_short_term"
    },
    "technology": "Conventional Hydroelectric"
   },
   {
    "capacity_mw": 62.1,
    "changed_on": "2026-08-01",
    "dates": {
     "operating": "1941-01-01",
     "planned_operating": null,
     "planned_retirement": null,
     "precision": "month",
     "retirement": null
    },
    "generator_id": "3",
    "id": "generator:eia:3075:3",
    "in_baseline": true,
    "life": "operating",
    "resource_group": "hydro",
    "status": {
     "category": "existing",
     "code": "OP",
     "label": "operating"
    },
    "technology": "Conventional Hydroelectric"
   },
   {
    "capacity_mw": 62.1,
    "changed_on": "2026-08-01",
    "dates": {
     "operating": "1941-02-01",
     "planned_operating": null,
     "planned_retirement": null,
     "precision": "month",
     "retirement": null
    },
    "generator_id": "4",
    "id": "generator:eia:3075:4",
    "in_baseline": true,
    "life": "operating",
    "resource_group": "hydro",
    "status": {
     "category": "existing",
     "code": "OP",
     "label": "operating"
    },
    "technology": "Conventional Hydroelectric"
   },
   {
    "capacity_mw": 62.1,
    "changed_on": "2026-08-01",
    "dates": {
     "operating": "1941-10-01",
     "planned_operating": null,
     "planned_retirement": null,
     "precision": "month",
     "retirement": null
    },
    "generator_id": "5",
    "id": "generator:eia:3075:5",
    "in_baseline": true,
    "life": "operating",
    "resource_group": "hydro",
    "status": {
     "category": "existing",
     "code": "OP",
     "label": "operating"
    },
    "technology": "Conventional Hydroelectric"
   },
   {
    "capacity_mw": 62.1,
    "changed_on": "2026-08-01",
    "dates": {
     "operating": "1942-06-01",
     "planned_operating": null,
     "planned_retirement": null,
     "precision": "month",
     "retirement": null
    },
    "generator_id": "6",
    "id": "generator:eia:3075:6",
    "in_baseline": true,
    "life": "operating",
    "resource_group": "hydro",
    "status": {
     "category": "existing",
     "code": "OP",
     "label": "operating"
    },
    "technology": "Conventional Hydroelectric"
   },
   {
    "capacity_mw": 62.1,
    "changed_on": "2026-08-01",
    "dates": {
     "operating": "1943-04-01",
     "planned_operating": null,
     "planned_retirement": null,
     "precision": "month",
     "retirement": null
    },
    "generator_id": "7",
    "id": "generator:eia:3075:7",
    "in_baseline": true,
    "life": "operating",
    "resource_group": "hydro",
    "status": {
     "category": "existing",
     "code": "OP",
     "label": "operating"
    },
    "technology": "Conventional Hydroelectric"
   },
   {
    "capacity_mw": 62.1,
    "changed_on": "2026-08-01",
    "dates": {
     "operating": "1943-07-01",
     "planned_operating": null,
     "planned_retirement": null,
     "precision": "month",
     "retirement": null
    },
    "generator_id": "8",
    "id": "generator:eia:3075:8",
    "in_baseline": true,
    "life": "operating",
    "resource_group": "hydro",
    "status": {
     "category": "existing",
     "code": "OP",
     "label": "operating"
    },
    "technology": "Conventional Hydroelectric"
   },
   {
    "capacity_mw": 62.1,
    "changed_on": "2026-08-01",
    "dates": {
     "operating": "1943-10-01",
     "planned_operating": null,
     "planned_retirement": null,
     "precision": "month",
     "retirement": null
    },
    "generator_id": "9",
    "id": "generator:eia:3075:9",
    "in_baseline": true,
    "life": "standby_or_out_of_service",
    "resource_group": "hydro",
    "status": {
     "category": "existing",
     "code": "OA",
     "label": "out_of_service_short_term"
    },
    "technology": "Conventional Hydroelectric"
   },
   {
    "capacity_mw": 13.1,
    "changed_on": "2026-08-01",
    "dates": {
     "operating": "1982-01-01",
     "planned_operating": null,
     "planned_retirement": null,
     "precision": "month",
     "retirement": null
    },
    "generator_id": "F1",
    "id": "generator:eia:3075:F1",
    "in_baseline": true,
    "life": "operating",
    "resource_group": "hydro",
    "status": {
     "category": "existing",
     "code": "OP",
     "label": "operating"
    },
    "technology": "Conventional Hydroelectric"
   },
   {
    "capacity_mw": 13.1,
    "changed_on": "2026-08-01",
    "dates": {
     "operating": "1981-11-01",
     "planned_operating": null,
     "planned_retirement": null,
     "precision": "month",
     "retirement": null
    },
    "generator_id": "F2",
    "id": "generator:eia:3075:F2",
    "in_baseline": true,
    "life": "standby_or_out_of_service",
    "resource_group": "hydro",
    "status": {
     "category": "existing",
     "code": "OA",
     "label": "out_of_service_short_term"
    },
    "technology": "Conventional Hydroelectric"
   }
  ]
 },
 "location": {
  "city": "Cascade Locks",
  "county": "Multnomah",
  "datum": null,
  "lat": 45.6441,
  "locator": "out_eia__yearly_plants.parquet; report_date=2024-01-01; plant_id_eia=3075",
  "lon": -121.941,
  "note": "Plant coordinate shared by all generators; not turbine or inverter locations. Source datum field empty in this edition.",
  "quality": "source_reported",
  "source_ref": "pudl-plants",
  "state": "OR",
  "timezone": "America/Los_Angeles"
 },
 "name": "Bonneville Lock and Dam",
 "operator": {
  "entity_type": "F",
  "entity_type_label": "Federally-owned utility",
  "id": "org:eia:19400",
  "name": "U.S. Army Corps of Engineers, Northwestern Division"
 },
 "output": {
  "annual": [
   {
    "components": [
     {
      "energy_source": {
       "code": "WAT",
       "fuel_group": "hydro",
       "label": "water"
      },
      "maturity": "final",
      "net_generation_mwh": 4127097.0,
      "prime_mover": {
       "code": "HY",
       "label": "hydraulic_turbine"
      }
     }
    ],
    "fact": {
     "basis": "Sum of EIA-923 annual net generation over the plant's unique prime-mover x energy-source rows; negative values (pumping, station use) retained",
     "coverage": {
      "eligible": 1,
      "included": 1,
      "unit": "plant x prime-mover x fuel rows"
     },
     "denominator": null,
     "evidence": "reported",
     "fact_id": "plant:eia:3075#net_generation_mwh@2015",
     "label": "Net generation",
     "locator": "out_eia923__yearly_generation_fuel_combined.parquet; report_date=2015-01-01; plant_id_eia=3075",
     "maturity": "final",
     "method": "derived",
     "metric": "net_generation_mwh",
     "missing_reason": null,
     "note": null,
     "period": {
      "hours": 8760,
      "kind": "calendar_year",
      "period_end": "2016-01-01T00:00:00Z",
      "period_start": "2015-01-01T00:00:00Z",
      "year": 2015
     },
     "precision": 0,
     "quality": "valid",
     "source_ref": "pudl-output",
     "unit": "MWh",
     "value": 4127097.0
    },
    "rows": 1,
    "year": 2015
   },
   {
    "components": [
     {
      "energy_source": {
       "code": "WAT",
       "fuel_group": "hydro",
       "label": "water"
      },
      "maturity": "final",
      "net_generation_mwh": 4625436.0,
      "prime_mover": {
       "code": "HY",
       "label": "hydraulic_turbine"
      }
     }
    ],
    "fact": {
     "basis": "Sum of EIA-923 annual net generation over the plant's unique prime-mover x energy-source rows; negative values (pumping, station use) retained",
     "coverage": {
      "eligible": 1,
      "included": 1,
      "unit": "plant x prime-mover x fuel rows"
     },
     "denominator": null,
     "evidence": "reported",
     "fact_id": "plant:eia:3075#net_generation_mwh@2016",
     "label": "Net generation",
     "locator": "out_eia923__yearly_generation_fuel_combined.parquet; report_date=2016-01-01; plant_id_eia=3075",
     "maturity": "final",
     "method": "derived",
     "metric": "net_generation_mwh",
     "missing_reason": null,
     "note": null,
     "period": {
      "hours": 8784,
      "kind": "calendar_year",
      "period_end": "2017-01-01T00:00:00Z",
      "period_start": "2016-01-01T00:00:00Z",
      "year": 2016
     },
     "precision": 0,
     "quality": "valid",
     "source_ref": "pudl-output",
     "unit": "MWh",
     "value": 4625436.0
    },
    "rows": 1,
    "year": 2016
   },
   {
    "components": [
     {
      "energy_source": {
       "code": "WAT",
       "fuel_group": "hydro",
       "label": "water"
      },
      "maturity": "final",
      "net_generation_mwh": 4834674.0,
      "prime_mover": {
       "code": "HY",
       "label": "hydraulic_turbine"
      }
     }
    ],
    "fact": {
     "basis": "Sum of EIA-923 annual net generation over the plant's unique prime-mover x energy-source rows; negative values (pumping, station use) retained",
     "coverage": {
      "eligible": 1,
      "included": 1,
      "unit": "plant x prime-mover x fuel rows"
     },
     "denominator": null,
     "evidence": "reported",
     "fact_id": "plant:eia:3075#net_generation_mwh@2017",
     "label": "Net generation",
     "locator": "out_eia923__yearly_generation_fuel_combined.parquet; report_date=2017-01-01; plant_id_eia=3075",
     "maturity": "final",
     "method": "derived",
     "metric": "net_generation_mwh",
     "missing_reason": null,
     "note": null,
     "period": {
      "hours": 8760,
      "kind": "calendar_year",
      "period_end": "2018-01-01T00:00:00Z",
      "period_start": "2017-01-01T00:00:00Z",
      "year": 2017
     },
     "precision": 0,
     "quality": "valid",
     "source_ref": "pudl-output",
     "unit": "MWh",
     "value": 4834674.0
    },
    "rows": 1,
    "year": 2017
   },
   {
    "components": [
     {
      "energy_source": {
       "code": "WAT",
       "fuel_group": "hydro",
       "label": "water"
      },
      "maturity": "final",
      "net_generation_mwh": 4859814.0,
      "prime_mover": {
       "code": "HY",
       "label": "hydraulic_turbine"
      }
     }
    ],
    "fact": {
     "basis": "Sum of EIA-923 annual net generation over the plant's unique prime-mover x energy-source rows; negative values (pumping, station use) retained",
     "coverage": {
      "eligible": 1,
      "included": 1,
      "unit": "plant x prime-mover x fuel rows"
     },
     "denominator": null,
     "evidence": "reported",
     "fact_id": "plant:eia:3075#net_generation_mwh@2018",
     "label": "Net generation",
     "locator": "out_eia923__yearly_generation_fuel_combined.parquet; report_date=2018-01-01; plant_id_eia=3075",
     "maturity": "final",
     "method": "derived",
     "metric": "net_generation_mwh",
     "missing_reason": null,
     "note": null,
     "period": {
      "hours": 8760,
      "kind": "calendar_year",
      "period_end": "2019-01-01T00:00:00Z",
      "period_start": "2018-01-01T00:00:00Z",
      "year": 2018
     },
     "precision": 0,
     "quality": "valid",
     "source_ref": "pudl-output",
     "unit": "MWh",
     "value": 4859814.0
    },
    "rows": 1,
    "year": 2018
   },
   {
    "components": [
     {
      "energy_source": {
       "code": "WAT",
       "fuel_group": "hydro",
       "label": "water"
      },
      "maturity": "final",
      "net_generation_mwh": 4207101.0,
      "prime_mover": {
       "code": "HY",
       "label": "hydraulic_turbine"
      }
     }
    ],
    "fact": {
     "basis": "Sum of EIA-923 annual net generation over the plant's unique prime-mover x energy-source rows; negative values (pumping, station use) retained",
     "coverage": {
      "eligible": 1,
      "included": 1,
      "unit": "plant x prime-mover x fuel rows"
     },
     "denominator": null,
     "evidence": "reported",
     "fact_id": "plant:eia:3075#net_generation_mwh@2019",
     "label": "Net generation",
     "locator": "out_eia923__yearly_generation_fuel_combined.parquet; report_date=2019-01-01; plant_id_eia=3075",
     "maturity": "final",
     "method": "derived",
     "metric": "net_generation_mwh",
     "missing_reason": null,
     "note": null,
     "period": {
      "hours": 8760,
      "kind": "calendar_year",
      "period_end": "2020-01-01T00:00:00Z",
      "period_start": "2019-01-01T00:00:00Z",
      "year": 2019
     },
     "precision": 0,
     "quality": "valid",
     "source_ref": "pudl-output",
     "unit": "MWh",
     "value": 4207101.0
    },
    "rows": 1,
    "year": 2019
   },
   {
    "components": [
     {
      "energy_source": {
       "code": "WAT",
       "fuel_group": "hydro",
       "label": "water"
      },
      "maturity": "final",
      "net_generation_mwh": 4669766.0,
      "prime_mover": {
       "code": "HY",
       "label": "hydraulic_turbine"
      }
     }
    ],
    "fact": {
     "basis": "Sum of EIA-923 annual net generation over the plant's unique prime-mover x energy-source rows; negative values (pumping, station use) retained",
     "coverage": {
      "eligible": 1,
      "included": 1,
      "unit": "plant x prime-mover x fuel rows"
     },
     "denominator": null,
     "evidence": "reported",
     "fact_id": "plant:eia:3075#net_generation_mwh@2020",
     "label": "Net generation",
     "locator": "out_eia923__yearly_generation_fuel_combined.parquet; report_date=2020-01-01; plant_id_eia=3075",
     "maturity": "final",
     "method": "derived",
     "metric": "net_generation_mwh",
     "missing_reason": null,
     "note": null,
     "period": {
      "hours": 8784,
      "kind": "calendar_year",
      "period_end": "2021-01-01T00:00:00Z",
      "period_start": "2020-01-01T00:00:00Z",
      "year": 2020
     },
     "precision": 0,
     "quality": "valid",
     "source_ref": "pudl-output",
     "unit": "MWh",
     "value": 4669766.0
    },
    "rows": 1,
    "year": 2020
   },
   {
    "components": [
     {
      "energy_source": {
       "code": "WAT",
       "fuel_group": "hydro",
       "label": "water"
      },
      "maturity": "final",
      "net_generation_mwh": 4010436.0,
      "prime_mover": {
       "code": "HY",
       "label": "hydraulic_turbine"
      }
     }
    ],
    "fact": {
     "basis": "Sum of EIA-923 annual net generation over the plant's unique prime-mover x energy-source rows; negative values (pumping, station use) retained",
     "coverage": {
      "eligible": 1,
      "included": 1,
      "unit": "plant x prime-mover x fuel rows"
     },
     "denominator": null,
     "evidence": "reported",
     "fact_id": "plant:eia:3075#net_generation_mwh@2021",
     "label": "Net generation",
     "locator": "out_eia923__yearly_generation_fuel_combined.parquet; report_date=2021-01-01; plant_id_eia=3075",
     "maturity": "final",
     "method": "derived",
     "metric": "net_generation_mwh",
     "missing_reason": null,
     "note": null,
     "period": {
      "hours": 8760,
      "kind": "calendar_year",
      "period_end": "2022-01-01T00:00:00Z",
      "period_start": "2021-01-01T00:00:00Z",
      "year": 2021
     },
     "precision": 0,
     "quality": "valid",
     "source_ref": "pudl-output",
     "unit": "MWh",
     "value": 4010436.0
    },
    "rows": 1,
    "year": 2021
   },
   {
    "components": [
     {
      "energy_source": {
       "code": "WAT",
       "fuel_group": "hydro",
       "label": "water"
      },
      "maturity": "final",
      "net_generation_mwh": 4681188.0,
      "prime_mover": {
       "code": "HY",
       "label": "hydraulic_turbine"
      }
     }
    ],
    "fact": {
     "basis": "Sum of EIA-923 annual net generation over the plant's unique prime-mover x energy-source rows; negative values (pumping, station use) retained",
     "coverage": {
      "eligible": 1,
      "included": 1,
      "unit": "plant x prime-mover x fuel rows"
     },
     "denominator": null,
     "evidence": "reported",
     "fact_id": "plant:eia:3075#net_generation_mwh@2022",
     "label": "Net generation",
     "locator": "out_eia923__yearly_generation_fuel_combined.parquet; report_date=2022-01-01; plant_id_eia=3075",
     "maturity": "final",
     "method": "derived",
     "metric": "net_generation_mwh",
     "missing_reason": null,
     "note": null,
     "period": {
      "hours": 8760,
      "kind": "calendar_year",
      "period_end": "2023-01-01T00:00:00Z",
      "period_start": "2022-01-01T00:00:00Z",
      "year": 2022
     },
     "precision": 0,
     "quality": "valid",
     "source_ref": "pudl-output",
     "unit": "MWh",
     "value": 4681188.0
    },
    "rows": 1,
    "year": 2022
   },
   {
    "components": [
     {
      "energy_source": {
       "code": "WAT",
       "fuel_group": "hydro",
       "label": "water"
      },
      "maturity": "final",
      "net_generation_mwh": 3631018.0,
      "prime_mover": {
       "code": "HY",
       "label": "hydraulic_turbine"
      }
     }
    ],
    "fact": {
     "basis": "Sum of EIA-923 annual net generation over the plant's unique prime-mover x energy-source rows; negative values (pumping, station use) retained",
     "coverage": {
      "eligible": 1,
      "included": 1,
      "unit": "plant x prime-mover x fuel rows"
     },
     "denominator": null,
     "evidence": "reported",
     "fact_id": "plant:eia:3075#net_generation_mwh@2023",
     "label": "Net generation",
     "locator": "out_eia923__yearly_generation_fuel_combined.parquet; report_date=2023-01-01; plant_id_eia=3075",
     "maturity": "final",
     "method": "derived",
     "metric": "net_generation_mwh",
     "missing_reason": null,
     "note": null,
     "period": {
      "hours": 8760,
      "kind": "calendar_year",
      "period_end": "2024-01-01T00:00:00Z",
      "period_start": "2023-01-01T00:00:00Z",
      "year": 2023
     },
     "precision": 0,
     "quality": "valid",
     "source_ref": "pudl-output",
     "unit": "MWh",
     "value": 3631018.0
    },
    "rows": 1,
    "year": 2023
   },
   {
    "components": [
     {
      "energy_source": {
       "code": "WAT",
       "fuel_group": "hydro",
       "label": "water"
      },
      "maturity": "final",
      "net_generation_mwh": 3492864.0,
      "prime_mover": {
       "code": "HY",
       "label": "hydraulic_turbine"
      }
     }
    ],
    "fact": {
     "basis": "Sum of EIA-923 annual net generation over the plant's unique prime-mover x energy-source rows; negative values (pumping, station use) retained",
     "coverage": {
      "eligible": 1,
      "included": 1,
      "unit": "plant x prime-mover x fuel rows"
     },
     "denominator": null,
     "evidence": "reported",
     "fact_id": "plant:eia:3075#net_generation_mwh@2024",
     "label": "Net generation",
     "locator": "out_eia923__yearly_generation_fuel_combined.parquet; report_date=2024-01-01; plant_id_eia=3075",
     "maturity": "final",
     "method": "derived",
     "metric": "net_generation_mwh",
     "missing_reason": null,
     "note": null,
     "period": {
      "hours": 8784,
      "kind": "calendar_year",
      "period_end": "2025-01-01T00:00:00Z",
      "period_start": "2024-01-01T00:00:00Z",
      "year": 2024
     },
     "precision": 0,
     "quality": "valid",
     "source_ref": "pudl-output",
     "unit": "MWh",
     "value": 3492864.0
    },
    "rows": 1,
    "year": 2024
   }
  ],
  "monthly": {
   "available": true,
   "basis": "Sum of unique plant x prime-mover x fuel rows per month; local calendar months as published by EIA; only years in which the respondent reported monthly (M) or monthly values once per year (AM)",
   "evidence": "reported",
   "frequency_sources": {
    "2015": "eia923-raw-2015",
    "2016": "eia923-raw-2016",
    "2017": "eia923-raw-2017",
    "2018": "pudl-plants",
    "2019": "pudl-plants",
    "2020": "pudl-plants",
    "2021": "pudl-plants",
    "2022": "pudl-plants",
    "2023": "pudl-plants",
    "2024": "pudl-plants"
   },
   "label": "Net generation, monthly",
   "locator": "out_eia923__monthly_generation_fuel_combined.parquet; plant_id_eia=3075",
   "maturity": "final",
   "method": "derived",
   "metric": "net_generation_mwh",
   "note": "Missing months absent, not zero; negative values retained; excluded years listed with reason",
   "period_kind": "calendar_month",
   "series_id": "plant:eia:3075#net_generation_mwh/monthly",
   "source_ref": "pudl-output-monthly",
   "unit": "MWh",
   "values": [
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2015-02-01T00:00:00Z",
     "period_start": "2015-01-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 605472.0
    },
    {
     "hours": 672,
     "maturity": "final",
     "period_end": "2015-03-01T00:00:00Z",
     "period_start": "2015-02-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 520978.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2015-04-01T00:00:00Z",
     "period_start": "2015-03-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 597705.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2015-05-01T00:00:00Z",
     "period_start": "2015-04-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 303030.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2015-06-01T00:00:00Z",
     "period_start": "2015-05-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 230218.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2015-07-01T00:00:00Z",
     "period_start": "2015-06-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 164407.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2015-08-01T00:00:00Z",
     "period_start": "2015-07-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 118392.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2015-09-01T00:00:00Z",
     "period_start": "2015-08-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 119642.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2015-10-01T00:00:00Z",
     "period_start": "2015-09-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 317339.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2015-11-01T00:00:00Z",
     "period_start": "2015-10-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 318373.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2015-12-01T00:00:00Z",
     "period_start": "2015-11-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 391646.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2016-01-01T00:00:00Z",
     "period_start": "2015-12-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 439895.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2016-02-01T00:00:00Z",
     "period_start": "2016-01-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 484952.0
    },
    {
     "hours": 696,
     "maturity": "final",
     "period_end": "2016-03-01T00:00:00Z",
     "period_start": "2016-02-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 518469.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2016-04-01T00:00:00Z",
     "period_start": "2016-03-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 612715.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2016-05-01T00:00:00Z",
     "period_start": "2016-04-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 496905.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2016-06-01T00:00:00Z",
     "period_start": "2016-05-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 407840.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2016-07-01T00:00:00Z",
     "period_start": "2016-06-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 266889.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2016-08-01T00:00:00Z",
     "period_start": "2016-07-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 160232.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2016-09-01T00:00:00Z",
     "period_start": "2016-08-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 113025.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2016-10-01T00:00:00Z",
     "period_start": "2016-09-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 302123.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2016-11-01T00:00:00Z",
     "period_start": "2016-10-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 383958.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2016-12-01T00:00:00Z",
     "period_start": "2016-11-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 406476.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2017-01-01T00:00:00Z",
     "period_start": "2016-12-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 471852.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2017-02-01T00:00:00Z",
     "period_start": "2017-01-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 532385.0
    },
    {
     "hours": 672,
     "maturity": "final",
     "period_end": "2017-03-01T00:00:00Z",
     "period_start": "2017-02-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 534180.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2017-04-01T00:00:00Z",
     "period_start": "2017-03-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 531661.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2017-05-01T00:00:00Z",
     "period_start": "2017-04-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 452019.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2017-06-01T00:00:00Z",
     "period_start": "2017-05-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 437927.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2017-07-01T00:00:00Z",
     "period_start": "2017-06-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 433295.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2017-08-01T00:00:00Z",
     "period_start": "2017-07-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 245915.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2017-09-01T00:00:00Z",
     "period_start": "2017-08-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 113739.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2017-10-01T00:00:00Z",
     "period_start": "2017-09-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 351362.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2017-11-01T00:00:00Z",
     "period_start": "2017-10-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 320723.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2017-12-01T00:00:00Z",
     "period_start": "2017-11-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 391620.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2018-01-01T00:00:00Z",
     "period_start": "2017-12-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 489848.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2018-02-01T00:00:00Z",
     "period_start": "2018-01-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 607218.0
    },
    {
     "hours": 672,
     "maturity": "final",
     "period_end": "2018-03-01T00:00:00Z",
     "period_start": "2018-02-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 590849.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2018-04-01T00:00:00Z",
     "period_start": "2018-03-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 603982.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2018-05-01T00:00:00Z",
     "period_start": "2018-04-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 476765.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2018-06-01T00:00:00Z",
     "period_start": "2018-05-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 436695.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2018-07-01T00:00:00Z",
     "period_start": "2018-06-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 401881.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2018-08-01T00:00:00Z",
     "period_start": "2018-07-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 210606.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2018-09-01T00:00:00Z",
     "period_start": "2018-08-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 121312.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2018-10-01T00:00:00Z",
     "period_start": "2018-09-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 297931.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2018-11-01T00:00:00Z",
     "period_start": "2018-10-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 301241.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2018-12-01T00:00:00Z",
     "period_start": "2018-11-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 393411.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2019-01-01T00:00:00Z",
     "period_start": "2018-12-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 417923.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2019-02-01T00:00:00Z",
     "period_start": "2019-01-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 459360.0
    },
    {
     "hours": 672,
     "maturity": "final",
     "period_end": "2019-03-01T00:00:00Z",
     "period_start": "2019-02-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 416846.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2019-04-01T00:00:00Z",
     "period_start": "2019-03-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 481770.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2019-05-01T00:00:00Z",
     "period_start": "2019-04-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 461610.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2019-06-01T00:00:00Z",
     "period_start": "2019-05-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 448699.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2019-07-01T00:00:00Z",
     "period_start": "2019-06-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 301749.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2019-08-01T00:00:00Z",
     "period_start": "2019-07-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 124991.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2019-09-01T00:00:00Z",
     "period_start": "2019-08-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 120490.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2019-10-01T00:00:00Z",
     "period_start": "2019-09-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 285245.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2019-11-01T00:00:00Z",
     "period_start": "2019-10-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 302607.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2019-12-01T00:00:00Z",
     "period_start": "2019-11-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 387535.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2020-01-01T00:00:00Z",
     "period_start": "2019-12-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 416199.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2020-02-01T00:00:00Z",
     "period_start": "2020-01-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 478787.0
    },
    {
     "hours": 696,
     "maturity": "final",
     "period_end": "2020-03-01T00:00:00Z",
     "period_start": "2020-02-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 543921.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2020-04-01T00:00:00Z",
     "period_start": "2020-03-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 445256.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2020-05-01T00:00:00Z",
     "period_start": "2020-04-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 221994.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2020-06-01T00:00:00Z",
     "period_start": "2020-05-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 435507.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2020-07-01T00:00:00Z",
     "period_start": "2020-06-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 470673.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2020-08-01T00:00:00Z",
     "period_start": "2020-07-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 332886.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2020-09-01T00:00:00Z",
     "period_start": "2020-08-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 233271.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2020-10-01T00:00:00Z",
     "period_start": "2020-09-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 331201.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2020-11-01T00:00:00Z",
     "period_start": "2020-10-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 330871.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2020-12-01T00:00:00Z",
     "period_start": "2020-11-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 404433.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2021-01-01T00:00:00Z",
     "period_start": "2020-12-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 440966.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2021-02-01T00:00:00Z",
     "period_start": "2021-01-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 552470.0
    },
    {
     "hours": 672,
     "maturity": "final",
     "period_end": "2021-03-01T00:00:00Z",
     "period_start": "2021-02-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 472526.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2021-04-01T00:00:00Z",
     "period_start": "2021-03-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 421379.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2021-05-01T00:00:00Z",
     "period_start": "2021-04-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 205629.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2021-06-01T00:00:00Z",
     "period_start": "2021-05-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 223509.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2021-07-01T00:00:00Z",
     "period_start": "2021-06-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 276411.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2021-08-01T00:00:00Z",
     "period_start": "2021-07-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 153242.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2021-09-01T00:00:00Z",
     "period_start": "2021-08-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 175068.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2021-10-01T00:00:00Z",
     "period_start": "2021-09-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 280584.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2021-11-01T00:00:00Z",
     "period_start": "2021-10-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 294241.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2021-12-01T00:00:00Z",
     "period_start": "2021-11-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 408150.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2022-01-01T00:00:00Z",
     "period_start": "2021-12-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 547227.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2022-02-01T00:00:00Z",
     "period_start": "2022-01-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 573295.0
    },
    {
     "hours": 672,
     "maturity": "final",
     "period_end": "2022-03-01T00:00:00Z",
     "period_start": "2022-02-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 499466.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2022-04-01T00:00:00Z",
     "period_start": "2022-03-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 527209.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2022-05-01T00:00:00Z",
     "period_start": "2022-04-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 217690.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2022-06-01T00:00:00Z",
     "period_start": "2022-05-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 276486.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2022-07-01T00:00:00Z",
     "period_start": "2022-06-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 438818.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2022-08-01T00:00:00Z",
     "period_start": "2022-07-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 407190.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2022-09-01T00:00:00Z",
     "period_start": "2022-08-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 282371.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2022-10-01T00:00:00Z",
     "period_start": "2022-09-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 329616.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2022-11-01T00:00:00Z",
     "period_start": "2022-10-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 284573.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2022-12-01T00:00:00Z",
     "period_start": "2022-11-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 396355.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2023-01-01T00:00:00Z",
     "period_start": "2022-12-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 448119.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2023-02-01T00:00:00Z",
     "period_start": "2023-01-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 440086.0
    },
    {
     "hours": 672,
     "maturity": "final",
     "period_end": "2023-03-01T00:00:00Z",
     "period_start": "2023-02-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 391704.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2023-04-01T00:00:00Z",
     "period_start": "2023-03-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 359620.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2023-05-01T00:00:00Z",
     "period_start": "2023-04-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 167316.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2023-06-01T00:00:00Z",
     "period_start": "2023-05-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 457095.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2023-07-01T00:00:00Z",
     "period_start": "2023-06-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 164057.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2023-08-01T00:00:00Z",
     "period_start": "2023-07-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 124363.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2023-09-01T00:00:00Z",
     "period_start": "2023-08-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 178537.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2023-10-01T00:00:00Z",
     "period_start": "2023-09-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 267372.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2023-11-01T00:00:00Z",
     "period_start": "2023-10-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 282654.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2023-12-01T00:00:00Z",
     "period_start": "2023-11-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 389656.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2024-01-01T00:00:00Z",
     "period_start": "2023-12-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 408558.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2024-02-01T00:00:00Z",
     "period_start": "2024-01-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 404682.0
    },
    {
     "hours": 696,
     "maturity": "final",
     "period_end": "2024-03-01T00:00:00Z",
     "period_start": "2024-02-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 397072.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2024-04-01T00:00:00Z",
     "period_start": "2024-03-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 420604.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2024-05-01T00:00:00Z",
     "period_start": "2024-04-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 206925.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2024-06-01T00:00:00Z",
     "period_start": "2024-05-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 149956.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2024-07-01T00:00:00Z",
     "period_start": "2024-06-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 192722.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2024-08-01T00:00:00Z",
     "period_start": "2024-07-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 157625.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2024-09-01T00:00:00Z",
     "period_start": "2024-08-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 212296.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2024-10-01T00:00:00Z",
     "period_start": "2024-09-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 268948.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2024-11-01T00:00:00Z",
     "period_start": "2024-10-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 268319.0
    },
    {
     "hours": 720,
     "maturity": "final",
     "period_end": "2024-12-01T00:00:00Z",
     "period_start": "2024-11-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 377582.0
    },
    {
     "hours": 744,
     "maturity": "final",
     "period_end": "2025-01-01T00:00:00Z",
     "period_start": "2024-12-01T00:00:00Z",
     "quality": "valid",
     "rows": 1,
     "value": 436133.0
    }
   ],
   "years_eligible": [
    2015,
    2016,
    2017,
    2018,
    2019,
    2020,
    2021,
    2022,
    2023,
    2024
   ],
   "years_excluded": []
  },
  "note": "Sum of unique plant x prime-mover x fuel rows per year; negative values retained; missing years absent, not zero; no monthly curve inferred",
  "reporter_frequency": "monthly"
 },
 "ownership_paths": {
  "available": false,
  "note": "Direct owners and their shares are in ownership_rollup and on each generator; no parent chain is curated for this plant, so no parent-attributed MW exists and none is implied",
  "reason": "parent_chain_not_curated",
  "source_ref": "ownership-parents"
 },
 "ownership_rollup": {
  "basis": "Operating nameplate MW x ownership fraction, once per generator; reported schedule or EIA-860 schedule-4 default",
  "note": null,
  "owners": [
   {
    "bases": [
     "eia860_schedule4_default"
    ],
    "generators": 11,
    "owned_mw": 656.3,
    "owner": {
     "entity_type": "F",
     "entity_type_label": "Federally-owned utility",
     "id": "org:eia:19400",
     "name": "U.S. Army Corps of Engineers, Northwestern Division"
    }
   }
  ],
  "unassigned_mw": 0.0,
  "unknown_coverage": {
   "eligible": 0,
   "included": 0,
   "unit": "native rows"
  },
  "unknown_mw": 0.0
 },
 "release_id": "20260929T050546Z-51ae0f7d3c78",
 "reporting": {
  "ba": {
   "code": "BPAT",
   "id": "ba:eia:BPAT",
   "name": "Bonneville Power Administration"
  },
  "ba_code_source": "BPAT",
  "frame_role": "core",
  "in_geographic_core": true,
  "in_reporting_frame": true,
  "inclusion_reason": "ba_in_frame_v1",
  "membership_review_status": "source",
  "reporter_frequency": "M"
 },
 "resource_group": "hydro",
 "schema_version": "1.41.0",
 "source_name": "Bonneville",
 "sources": [
  "curated-aliases",
  "ornl-eha-2026",
  "ornl-hilarri-v4",
  "pudl-generators",
  "pudl-output",
  "pudl-ownership",
  "pudl-plants",
  "usace-cwms-history",
  "usace-nid"
 ],
 "storage": null,
 "type": "plant",
 "updated_reason": null,
 "water": {
  "attribution": "U.S. Army Corps of Engineers, Northwestern Division, CWMS Data API (revised CBT series, as served at retrieval)",
  "available": true,
  "checks": [
   {
    "id": "water.units_match_declared",
    "passed": true,
    "severity": "block"
   },
   {
    "id": "water.missing_stays_null",
    "passed": true,
    "severity": "block"
   },
   {
    "id": "water.location_key_verified",
    "passed": true,
    "severity": "review"
   },
   {
    "id": "water.series_complete",
    "passed": true,
    "severity": "review"
   }
  ],
  "episode": {
   "id": "january-2024-cold-spell",
   "path": "episodes/january-2024-cold-spell.json",
   "title": "January 2024 cold spell"
  },
  "hours": [
   "2024-01-10T09:00:00Z",
   "2024-01-10T10:00:00Z",
   "2024-01-10T11:00:00Z",
   "2024-01-10T12:00:00Z",
   "2024-01-10T13:00:00Z",
   "2024-01-10T14:00:00Z",
   "2024-01-10T15:00:00Z",
   "2024-01-10T16:00:00Z",
   "2024-01-10T17:00:00Z",
   "2024-01-10T18:00:00Z",
   "2024-01-10T19:00:00Z",
   "2024-01-10T20:00:00Z",
   "2024-01-10T21:00:00Z",
   "2024-01-10T22:00:00Z",
   "2024-01-10T23:00:00Z",
   "2024-01-11T00:00:00Z",
   "2024-01-11T01:00:00Z",
   "2024-01-11T02:00:00Z",
   "2024-01-11T03:00:00Z",
   "2024-01-11T04:00:00Z",
   "2024-01-11T05:00:00Z",
   "2024-01-11T06:00:00Z",
   "2024-01-11T07:00:00Z",
   "2024-01-11T08:00:00Z",
   "2024-01-11T09:00:00Z",
   "2024-01-11T10:00:00Z",
   "2024-01-11T11:00:00Z",
   "2024-01-11T12:00:00Z",
   "2024-01-11T13:00:00Z",
   "2024-01-11T14:00:00Z",
   "2024-01-11T15:00:00Z",
   "2024-01-11T16:00:00Z",
   "2024-01-11T17:00:00Z",
   "2024-01-11T18:00:00Z",
   "2024-01-11T19:00:00Z",
   "2024-01-11T20:00:00Z",
   "2024-01-11T21:00:00Z",
   "2024-01-11T22:00:00Z",
   "2024-01-11T23:00:00Z",
   "2024-01-12T00:00:00Z",
   "2024-01-12T01:00:00Z",
   "2024-01-12T02:00:00Z",
   "2024-01-12T03:00:00Z",
   "2024-01-12T04:00:00Z",
   "2024-01-12T05:00:00Z",
   "2024-01-12T06:00:00Z",
   "2024-01-12T07:00:00Z",
   "2024-01-12T08:00:00Z",
   "2024-01-12T09:00:00Z",
   "2024-01-12T10:00:00Z",
   "2024-01-12T11:00:00Z",
   "2024-01-12T12:00:00Z",
   "2024-01-12T13:00:00Z",
   "2024-01-12T14:00:00Z",
   "2024-01-12T15:00:00Z",
   "2024-01-12T16:00:00Z",
   "2024-01-12T17:00:00Z",
   "2024-01-12T18:00:00Z",
   "2024-01-12T19:00:00Z",
   "2024-01-12T20:00:00Z",
   "2024-01-12T21:00:00Z",
   "2024-01-12T22:00:00Z",
   "2024-01-12T23:00:00Z",
   "2024-01-13T00:00:00Z",
   "2024-01-13T01:00:00Z",
   "2024-01-13T02:00:00Z",
   "2024-01-13T03:00:00Z",
   "2024-01-13T04:00:00Z",
   "2024-01-13T05:00:00Z",
   "2024-01-13T06:00:00Z",
   "2024-01-13T07:00:00Z",
   "2024-01-13T08:00:00Z",
   "2024-01-13T09:00:00Z",
   "2024-01-13T10:00:00Z",
   "2024-01-13T11:00:00Z",
   "2024-01-13T12:00:00Z",
   "2024-01-13T13:00:00Z",
   "2024-01-13T14:00:00Z",
   "2024-01-13T15:00:00Z",
   "2024-01-13T16:00:00Z",
   "2024-01-13T17:00:00Z",
   "2024-01-13T18:00:00Z",
   "2024-01-13T19:00:00Z",
   "2024-01-13T20:00:00Z",
   "2024-01-13T21:00:00Z",
   "2024-01-13T22:00:00Z",
   "2024-01-13T23:00:00Z",
   "2024-01-14T00:00:00Z",
   "2024-01-14T01:00:00Z",
   "2024-01-14T02:00:00Z",
   "2024-01-14T03:00:00Z",
   "2024-01-14T04:00:00Z",
   "2024-01-14T05:00:00Z",
   "2024-01-14T06:00:00Z",
   "2024-01-14T07:00:00Z",
   "2024-01-14T08:00:00Z",
   "2024-01-14T09:00:00Z",
   "2024-01-14T10:00:00Z",
   "2024-01-14T11:00:00Z",
   "2024-01-14T12:00:00Z",
   "2024-01-14T13:00:00Z",
   "2024-01-14T14:00:00Z",
   "2024-01-14T15:00:00Z",
   "2024-01-14T16:00:00Z",
   "2024-01-14T17:00:00Z",
   "2024-01-14T18:00:00Z",
   "2024-01-14T19:00:00Z",
   "2024-01-14T20:00:00Z",
   "2024-01-14T21:00:00Z",
   "2024-01-14T22:00:00Z",
   "2024-01-14T23:00:00Z",
   "2024-01-15T00:00:00Z",
   "2024-01-15T01:00:00Z",
   "2024-01-15T02:00:00Z",
   "2024-01-15T03:00:00Z",
   "2024-01-15T04:00:00Z",
   "2024-01-15T05:00:00Z",
   "2024-01-15T06:00:00Z",
   "2024-01-15T07:00:00Z",
   "2024-01-15T08:00:00Z",
   "2024-01-15T09:00:00Z",
   "2024-01-15T10:00:00Z",
   "2024-01-15T11:00:00Z",
   "2024-01-15T12:00:00Z",
   "2024-01-15T13:00:00Z",
   "2024-01-15T14:00:00Z",
   "2024-01-15T15:00:00Z",
   "2024-01-15T16:00:00Z",
   "2024-01-15T17:00:00Z",
   "2024-01-15T18:00:00Z",
   "2024-01-15T19:00:00Z",
   "2024-01-15T20:00:00Z",
   "2024-01-15T21:00:00Z",
   "2024-01-15T22:00:00Z",
   "2024-01-15T23:00:00Z",
   "2024-01-16T00:00:00Z",
   "2024-01-16T01:00:00Z",
   "2024-01-16T02:00:00Z",
   "2024-01-16T03:00:00Z",
   "2024-01-16T04:00:00Z",
   "2024-01-16T05:00:00Z",
   "2024-01-16T06:00:00Z",
   "2024-01-16T07:00:00Z",
   "2024-01-16T08:00:00Z",
   "2024-01-16T09:00:00Z",
   "2024-01-16T10:00:00Z",
   "2024-01-16T11:00:00Z",
   "2024-01-16T12:00:00Z",
   "2024-01-16T13:00:00Z",
   "2024-01-16T14:00:00Z",
   "2024-01-16T15:00:00Z",
   "2024-01-16T16:00:00Z",
   "2024-01-16T17:00:00Z",
   "2024-01-16T18:00:00Z",
   "2024-01-16T19:00:00Z",
   "2024-01-16T20:00:00Z",
   "2024-01-16T21:00:00Z",
   "2024-01-16T22:00:00Z",
   "2024-01-16T23:00:00Z",
   "2024-01-17T00:00:00Z",
   "2024-01-17T01:00:00Z",
   "2024-01-17T02:00:00Z",
   "2024-01-17T03:00:00Z",
   "2024-01-17T04:00:00Z",
   "2024-01-17T05:00:00Z",
   "2024-01-17T06:00:00Z",
   "2024-01-17T07:00:00Z",
   "2024-01-17T08:00:00Z",
   "2024-01-17T09:00:00Z",
   "2024-01-17T10:00:00Z",
   "2024-01-17T11:00:00Z",
   "2024-01-17T12:00:00Z",
   "2024-01-17T13:00:00Z",
   "2024-01-17T14:00:00Z",
   "2024-01-17T15:00:00Z",
   "2024-01-17T16:00:00Z",
   "2024-01-17T17:00:00Z",
   "2024-01-17T18:00:00Z",
   "2024-01-17T19:00:00Z",
   "2024-01-17T20:00:00Z",
   "2024-01-17T21:00:00Z",
   "2024-01-17T22:00:00Z",
   "2024-01-17T23:00:00Z",
   "2024-01-18T00:00:00Z",
   "2024-01-18T01:00:00Z",
   "2024-01-18T02:00:00Z",
   "2024-01-18T03:00:00Z",
   "2024-01-18T04:00:00Z",
   "2024-01-18T05:00:00Z",
   "2024-01-18T06:00:00Z",
   "2024-01-18T07:00:00Z",
   "2024-01-18T08:00:00Z",
   "2024-01-18T09:00:00Z",
   "2024-01-18T10:00:00Z",
   "2024-01-18T11:00:00Z",
   "2024-01-18T12:00:00Z",
   "2024-01-18T13:00:00Z",
   "2024-01-18T14:00:00Z",
   "2024-01-18T15:00:00Z",
   "2024-01-18T16:00:00Z",
   "2024-01-18T17:00:00Z",
   "2024-01-18T18:00:00Z",
   "2024-01-18T19:00:00Z",
   "2024-01-18T20:00:00Z",
   "2024-01-18T21:00:00Z",
   "2024-01-18T22:00:00Z",
   "2024-01-18T23:00:00Z",
   "2024-01-19T00:00:00Z",
   "2024-01-19T01:00:00Z",
   "2024-01-19T02:00:00Z",
   "2024-01-19T03:00:00Z",
   "2024-01-19T04:00:00Z",
   "2024-01-19T05:00:00Z",
   "2024-01-19T06:00:00Z",
   "2024-01-19T07:00:00Z",
   "2024-01-19T08:00:00Z",
   "2024-01-19T09:00:00Z",
   "2024-01-19T10:00:00Z",
   "2024-01-19T11:00:00Z",
   "2024-01-19T12:00:00Z",
   "2024-01-19T13:00:00Z",
   "2024-01-19T14:00:00Z",
   "2024-01-19T15:00:00Z",
   "2024-01-19T16:00:00Z",
   "2024-01-19T17:00:00Z",
   "2024-01-19T18:00:00Z",
   "2024-01-19T19:00:00Z",
   "2024-01-19T20:00:00Z",
   "2024-01-19T21:00:00Z",
   "2024-01-19T22:00:00Z",
   "2024-01-19T23:00:00Z",
   "2024-01-20T00:00:00Z",
   "2024-01-20T01:00:00Z",
   "2024-01-20T02:00:00Z",
   "2024-01-20T03:00:00Z",
   "2024-01-20T04:00:00Z",
   "2024-01-20T05:00:00Z",
   "2024-01-20T06:00:00Z",
   "2024-01-20T07:00:00Z",
   "2024-01-20T08:00:00Z"
  ],
  "key": {
   "basis": "USACE's NIDID agency-alias group maps NID OR00001 (this plant's reviewed dam) to NWDP location BON; CWMS location 'Bonneville Lock and Dam' is a PROJECT in OR, 0.25 km from the EIA plant point; its name shares 'bonneville' with the NID dam name",
   "dam_names": [
    "Bonneville Locks and Dam"
   ],
   "distance_km": 0.25,
   "failures": [],
   "group": "NIDID",
   "group_retrieved_at": "2026-09-29T04:58:57Z",
   "group_url": "https://cwms-data.usace.army.mil/cwms-data/location/group/NIDID?office=CWMS&category-id=Agency%20Aliases&group-office-id=CWMS",
   "nid_ids": [
    "OR00001"
   ],
   "reviewed_on": "2026-09-28",
   "reviewer": "claude-w67",
   "shared_name_tokens": [
    "bonneville"
   ],
   "verified": true
  },
  "license": "U.S. government work; public API, no terms stated",
  "location": {
   "horizontal_datum": "WGS84",
   "id": "BON",
   "latitude": 45.6458333,
   "location_kind": "PROJECT",
   "long_name": "Bonneville Dam and Lake On Columbia River",
   "longitude": -121.9388889,
   "office": "NWDP",
   "public_name": "Bonneville Lock and Dam",
   "retrieved_at": "2026-09-29T04:59:26Z",
   "state_initial": "OR",
   "timezone_name": "US/Pacific",
   "url": "https://cwms-data.usace.army.mil/cwms-data/locations/BON?office=NWDP",
   "vertical_datum": "NGVD29"
  },
  "naming_url": "https://www.hec.usace.army.mil/confluence/cwmsdocs/ccm/files/179601432/179602423/1/1705949779758/2016.03_CWMS_NamingStandard_March2016.pdf",
  "not_yet_included": [],
  "quality": "Each value keeps the CWMS quality code it was served with; code 0 is CWMS's code for an unscreened value. A value served with CDA's missing-value placeholder, or with a code that marks it missing or rejected, is shown as missing.",
  "reason": null,
  "revisions": "The API serves these series unversioned: USACE revises values in place, so a later retrieval can differ. These are the publisher's revised series as served at the retrieval time recorded with each query.",
  "scales": {
   "cfs": {
    "max": 137900.0,
    "min": 70500.0
   },
   "ft": {
    "max": 12.3,
    "min": 11.3
   }
  },
  "series": [
   {
    "available": true,
    "convention": "hour_ending_average",
    "convention_text": "The mean over the hour ending at the stamp, the same hour-ending convention as the episode",
    "cwms_id": "BON.Flow-Out.Ave.1Hour.1Hour.CBT-REV",
    "date_version_type": "UNVERSIONED",
    "expected": 240,
    "grain": "hour",
    "key": "outflow",
    "label": "Outflow",
    "max": 137900.0,
    "min": 70500.0,
    "missing": [],
    "parameter": "Flow-Out",
    "present": 240,
    "quality_codes": [
     0
    ],
    "query_url": "https://cwms-data.usace.army.mil/cwms-data/timeseries?office=NWDP&name=BON.Flow-Out.Ave.1Hour.1Hour.CBT-REV&begin=2024-01-10T08:00:00Z&end=2024-01-20T08:00:00Z&unit=EN&page-size=10000",
    "reason": null,
    "retrieved_at": "2026-09-29T05:01:09Z",
    "service": "cwms",
    "sha256": "8ad3068967238ef7af7a0829da8ccc64af8790266f487f366d947475afa3f8f8",
    "source_ref": "usace-cwms-history",
    "stamp_rule": "The CWMS Data API serves this stamp in UTC (epoch milliseconds); it is shown as served",
    "time_zone": "US/Pacific",
    "unit": "cfs",
    "values": [
     98800.0,
     98300.0,
     104000.0,
     105100.0,
     105400.0,
     107000.0,
     106900.0,
     104200.0,
     100500.0,
     97600.0,
     98300.0,
     98700.0,
     101300.0,
     103200.0,
     105300.0,
     105100.0,
     97600.0,
     83500.0,
     73300.0,
     77400.0,
     80400.0,
     86700.0,
     95500.0,
     102300.0,
     99100.0,
     101900.0,
     104900.0,
     109900.0,
     110400.0,
     110800.0,
     106800.0,
     104600.0,
     104400.0,
     103400.0,
     101500.0,
     102000.0,
     101600.0,
     99800.0,
     100500.0,
     102500.0,
     102300.0,
     97600.0,
     83300.0,
     72700.0,
     70500.0,
     73900.0,
     79900.0,
     85300.0,
     88500.0,
     93100.0,
     96600.0,
     98400.0,
     104600.0,
     106300.0,
     106200.0,
     105200.0,
     103400.0,
     101400.0,
     100900.0,
     103200.0,
     104000.0,
     108400.0,
     108800.0,
     113000.0,
     114500.0,
     115400.0,
     114300.0,
     116700.0,
     114300.0,
     110600.0,
     106800.0,
     108100.0,
     116700.0,
     119300.0,
     123600.0,
     123800.0,
     127300.0,
     129800.0,
     131500.0,
     134900.0,
     131600.0,
     128900.0,
     129800.0,
     129000.0,
     128300.0,
     132400.0,
     133700.0,
     136700.0,
     136200.0,
     135900.0,
     134500.0,
     134000.0,
     134300.0,
     132800.0,
     128500.0,
     123900.0,
     126000.0,
     127600.0,
     125900.0,
     125600.0,
     127800.0,
     133000.0,
     129400.0,
     129600.0,
     130700.0,
     130300.0,
     125800.0,
     122600.0,
     121600.0,
     120600.0,
     121600.0,
     122400.0,
     124100.0,
     122800.0,
     126000.0,
     127400.0,
     127100.0,
     126700.0,
     125800.0,
     123600.0,
     124400.0,
     123600.0,
     123900.0,
     125600.0,
     126300.0,
     128200.0,
     134500.0,
     137400.0,
     135000.0,
     136900.0,
     137400.0,
     134600.0,
     132800.0,
     130500.0,
     129600.0,
     135600.0,
     130200.0,
     131500.0,
     131100.0,
     131500.0,
     132700.0,
     132600.0,
     134300.0,
     134900.0,
     130600.0,
     130500.0,
     129200.0,
     129000.0,
     128800.0,
     129000.0,
     132900.0,
     136000.0,
     136500.0,
     137700.0,
     137900.0,
     134100.0,
     134600.0,
     133900.0,
     133200.0,
     131600.0,
     130200.0,
     132100.0,
     130600.0,
     131100.0,
     132400.0,
     133600.0,
     131700.0,
     131600.0,
     121900.0,
     121800.0,
     120900.0,
     123700.0,
     122800.0,
     123100.0,
     125500.0,
     124900.0,
     133900.0,
     126400.0,
     123600.0,
     120900.0,
     114500.0,
     101500.0,
     101800.0,
     102200.0,
     105400.0,
     105400.0,
     108300.0,
     110300.0,
     111800.0,
     114300.0,
     116100.0,
     115100.0,
     113600.0,
     111500.0,
     111000.0,
     111300.0,
     113800.0,
     116200.0,
     118300.0,
     124600.0,
     125400.0,
     125900.0,
     126300.0,
     120900.0,
     120600.0,
     115700.0,
     115900.0,
     115500.0,
     117500.0,
     112300.0,
     116300.0,
     118900.0,
     119600.0,
     120600.0,
     121700.0,
     122600.0,
     122700.0,
     124800.0,
     126400.0,
     126000.0,
     124700.0,
     124400.0,
     123500.0,
     128100.0,
     128300.0,
     128400.0,
     127800.0,
     127300.0,
     122500.0,
     119700.0,
     114200.0,
     113200.0,
     112800.0,
     110800.0,
     111000.0,
     118600.0,
     117800.0,
     117300.0,
     119200.0,
     119600.0
    ],
    "vertical_datum": null
   },
   {
    "available": true,
    "convention": "instantaneous",
    "convention_text": "The reading at the stamp: the end of each hour shown",
    "cwms_id": "BON.Elev-Tailwater.Inst.1Hour.0.CBT-REV",
    "date_version_type": "UNVERSIONED",
    "expected": 240,
    "grain": "hour",
    "key": "tailwater_elevation",
    "label": "Tailwater elevation",
    "max": 12.3,
    "min": 11.3,
    "missing": [],
    "parameter": "Elev-Tailwater",
    "present": 240,
    "quality_codes": [
     0
    ],
    "query_url": "https://cwms-data.usace.army.mil/cwms-data/timeseries?office=NWDP&name=BON.Elev-Tailwater.Inst.1Hour.0.CBT-REV&begin=2024-01-10T08:00:00Z&end=2024-01-20T08:00:00Z&unit=EN&page-size=10000",
    "reason": null,
    "retrieved_at": "2026-09-29T05:01:11Z",
    "service": "cwms",
    "sha256": "f9a62831e8c330c3be9ede3afc59a873a0693b87a9a9867c30c37c533e9a3617",
    "source_ref": "usace-cwms-history",
    "stamp_rule": "The CWMS Data API serves this stamp in UTC (epoch milliseconds); it is shown as served",
    "time_zone": "US/Pacific",
    "unit": "ft",
    "values": [
     11.6,
     11.6,
     11.5,
     11.5,
     11.6,
     11.6,
     11.7,
     11.7,
     11.5,
     11.3,
     11.3,
     11.3,
     11.3,
     11.4,
     11.5,
     11.6,
     11.6,
     11.6,
     11.4,
     11.4,
     11.4,
     11.4,
     11.6,
     11.7,
     11.5,
     11.5,
     11.6,
     11.8,
     11.6,
     11.6,
     11.6,
     11.6,
     11.7,
     11.7,
     11.7,
     11.6,
     11.6,
     11.4,
     11.6,
     11.7,
     11.9,
     12.3,
     12.3,
     11.9,
     11.6,
     11.6,
     11.5,
     11.6,
     11.6,
     11.5,
     11.5,
     11.5,
     11.6,
     11.6,
     11.7,
     11.6,
     11.6,
     11.5,
     11.4,
     11.5,
     11.3,
     11.5,
     11.3,
     11.4,
     11.5,
     11.6,
     11.7,
     12.0,
     12.1,
     11.7,
     11.6,
     11.5,
     11.8,
     11.7,
     11.8,
     11.7,
     11.8,
     11.8,
     11.9,
     11.9,
     11.7,
     11.8,
     11.8,
     11.7,
     11.6,
     11.8,
     11.7,
     11.9,
     11.9,
     11.9,
     11.9,
     12.1,
     12.2,
     12.2,
     12.1,
     11.9,
     12.0,
     12.0,
     11.8,
     11.8,
     11.8,
     12.0,
     11.9,
     11.9,
     12.0,
     12.2,
     12.0,
     12.0,
     11.9,
     11.9,
     11.8,
     11.8,
     11.9,
     11.6,
     11.8,
     12.0,
     12.0,
     12.1,
     12.0,
     12.0,
     11.9,
     11.9,
     11.8,
     11.7,
     11.7,
     11.6,
     12.0,
     12.0,
     12.0,
     12.1,
     12.3,
     12.1,
     12.1,
     12.1,
     12.1,
     12.3,
     11.8,
     11.9,
     11.8,
     11.8,
     11.8,
     11.8,
     12.0,
     12.1,
     11.9,
     11.9,
     11.8,
     11.7,
     11.7,
     11.6,
     11.8,
     11.8,
     12.0,
     12.0,
     12.1,
     12.0,
     12.1,
     12.0,
     12.0,
     11.8,
     11.9,
     11.9,
     11.7,
     11.8,
     11.7,
     11.8,
     11.8,
     11.9,
     11.4,
     11.4,
     11.5,
     11.5,
     11.4,
     11.4,
     11.5,
     11.7,
     11.8,
     11.5,
     11.8,
     11.9,
     11.9,
     11.3,
     11.5,
     11.4,
     11.5,
     11.4,
     11.5,
     11.4,
     11.4,
     11.5,
     11.6,
     11.6,
     11.6,
     11.5,
     11.4,
     11.3,
     11.3,
     11.3,
     11.3,
     11.5,
     11.5,
     11.6,
     11.6,
     11.5,
     11.7,
     11.6,
     11.5,
     11.5,
     11.6,
     11.3,
     11.4,
     11.4,
     11.4,
     11.4,
     11.4,
     11.4,
     11.4,
     11.4,
     11.6,
     11.5,
     11.5,
     11.4,
     11.4,
     11.6,
     11.6,
     11.6,
     11.7,
     11.7,
     11.6,
     11.6,
     11.5,
     11.6,
     11.6,
     11.3,
     11.4,
     11.7,
     11.5,
     11.5,
     11.5,
     11.5
    ],
    "vertical_datum": "NGVD29"
   }
  ],
  "services": [
   {
    "attribution": "U.S. Army Corps of Engineers, Northwestern Division, CWMS Data API (revised CBT series, as served at retrieval)",
    "landing_url": "https://cwms-data.usace.army.mil/cwms-data/",
    "license": "U.S. government work; public API, no terms stated",
    "name": "CWMS Data API",
    "service": "cwms",
    "source_ref": "usace-cwms-history"
   }
  ],
  "source_ref": "usace-cwms-history",
  "spec_url": "https://cwms-data.usace.army.mil/cwms-data/swagger-ui.html",
  "statement": "USACE's revised (CBT-REV) river and reservoir series at the project this plant belongs to, as the CWMS Data API served them. Water quantities, not generation: the API serves no generation series for this project, and the plant's generation on this page is EIA-923's.",
  "window": {
   "end": "2024-01-20T08:00:00Z",
   "first_hour": "2024-01-10T09:00:00Z",
   "hours": 240,
   "last_hour": "2024-01-20T08:00:00Z",
   "rule": "The window is the half-open UTC interval [start, end). The source stamps an hour at its end, so the window holds the hours stamped after start up to and including end.",
   "start": "2024-01-10T08:00:00Z"
  }
 }
}