 "aggregation_bucket": null,
 "aliases": [
  {
   "relation": "exact",
   "review_state": "source",
   "source_entity_id": "15500",
   "source_ref": "pudl-utilities"
  },
  {
   "kind": "alias",
   "note": "acronym used on own site",
   "relation": "exact",
   "review_state": "reviewed",
   "reviewed_on": "2026-09-18",
   "source_entity_id": "PSE",
   "source_ref": "curated-aliases",
   "source_url": "https://www.pse.com/en/about-us"
  },
  {
   "kind": "display_name",
   "note": "drops trailing Inc",
   "relation": "exact",
   "review_state": "reviewed",
   "reviewed_on": "2026-09-18",
   "source_entity_id": "Puget Sound Energy",
   "source_ref": "curated-aliases",
   "source_url": "https://www.pse.com/en/about-us"
  }
 ],
 "carbon_allowances": {
  "available": true,
  "compliance_period": "1",
  "ecology_name": "Puget Sound Energy",
  "link_basis": "name_exact_normalized",
  "market_reference": {
   "auction_date": "2026-09-02",
   "auction_number": 15,
   "consigned_allowances_sold": 3484205,
   "fact": {
    "basis": "The utility's no-cost allocation for the year multiplied by the settlement price of the most recent quarterly Cap-and-Invest auction. An illustration of scale, not revenue received: a utility consigns only part of its allocation, the price changes every quarter, and the proceeds of any sale must go back to customers",
    "coverage": null,
    "denominator": null,
    "evidence": "reported",
    "fact_id": "org:eia:15500#cca_allowance_value_usd@2026",
    "label": "No-cost allowances at the last auction price",
    "locator": "auction #15 2026-09-02; Puget Sound Energy; 2026",
    "maturity": "final",
    "method": "derived",
    "metric": "cca_allowance_value_usd",
    "missing_reason": null,
    "note": "2026 allocation at the $39.50 settlement price of auction #15 on 2026-09-02",
    "period": {
     "hours": null,
     "kind": "calendar_year",
     "period_end": "2027-01-01T00:00:00Z",
     "period_start": "2026-01-01T00:00:00Z",
     "year": 2026
    },
    "precision": 0,
    "quality": "valid",
    "source_ref": "wa-ecology-cca-auctions",
    "unit": "USD",
    "value": 183760636.0
   },
   "note": "What the allocation would fetch at one auction's price. Utilities consign part of their allowances to these auctions and must return the proceeds to customers; the rest they hold for compliance or bank.",
   "price_usd": 39.5,
   "source_ref": "wa-ecology-cca-auctions",
   "source_url": "https://apps.ecology.wa.gov/publications/SummaryPages/2614063.html",
   "vintages": "2023-2026",
   "year": 2026
  },
  "note": "An allocation of allowances, not a measurement of emissions and not a cap on the utility. Ecology computes it from its forecast of the utility's Washington retail load and resource supply, and reissues the schedule as forecasts and the BPA emission factor change; the supply shares here are that forecast, not the disclosed fuel mix.",
  "notice": "No-cost allowances a CETA-obligated electric utility receives under the Climate Commitment Act (WAC 173-446-230), one allowance = 1 metric ton CO2e, for compliance period 1 (2023-2026). The schedule is an allocation, not an emissions measurement and not a cap on the utility: it is computed from Ecology's forecast of the utility's Washington retail load and resource supply mix, with the BPA emission factor updated each year. Years after 2026 are TBD in the workbook and are not published. A utility may not sell or trade these allowances to other entities: it uses them for compliance, banks them, transfers them to an eligible generator or power marketing administration, or consigns them to a quarterly auction, and auction proceeds must benefit customers with priority on low-income rate impacts. Utility names are Ecology's; the link to an organization is the reviewed crosswalk only.",
  "source_ref": "wa-ecology-cca-allowances",
  "years": [
   {
    "adjustments": [],
    "allowances": {
     "basis": "Ecology's Electric Utility Allowance Allocation Schedule under WAC 173-446-230: allowances allocated at no cost to a CETA-obligated electric utility for the calendar year, one allowance = one metric ton of CO2 equivalent. An allocation computed from Ecology's forecast of the utility's Washington retail load and resource supply, not measured emissions and not a cap on the utility",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "org:eia:15500#cca_no_cost_allowances_tco2e@2023",
     "label": "No-cost carbon allowances",
     "locator": "sheet AllowanceAllocation; Puget Sound Energy; 2023",
     "maturity": "final",
     "method": "direct",
     "metric": "cca_no_cost_allowances_tco2e",
     "missing_reason": null,
     "note": null,
     "period": {
      "hours": null,
      "kind": "calendar_year",
      "period_end": "2024-01-01T00:00:00Z",
      "period_start": "2023-01-01T00:00:00Z",
      "year": 2023
     },
     "precision": 0,
     "quality": "valid",
     "source_ref": "wa-ecology-cca-allowances",
     "unit": "t CO2e",
     "value": 6642604.0
    },
    "forecast_load": {
     "basis": "Forecasted Retail Load in Ecology's allocation workbook: the load forecast the no-cost allowance allocation was computed from, taken from the utility's own filing (CEIP, IRP, supplemental forecast or BPA rate-case billing determinants). A forecast for one regulatory purpose, not a measurement of sales",
     "coverage": null,
     "denominator": null,
     "evidence": "modeled",
     "fact_id": "org:eia:15500#cca_forecast_retail_load_mwh@2023",
     "label": "Washington retail load, Ecology's allocation forecast",
     "locator": "sheet DataCalcs; Puget Sound Energy; 2023",
     "maturity": "final",
     "method": "direct",
     "metric": "cca_forecast_retail_load_mwh",
     "missing_reason": null,
     "note": "Ecology's load forecast for the allocation, from UTC Docket UE-220797 Revised 07/12/23",
     "period": {
      "hours": null,
      "kind": "calendar_year",
      "period_end": "2024-01-01T00:00:00Z",
      "period_start": "2023-01-01T00:00:00Z",
      "year": 2023
     },
     "precision": 0,
     "quality": "valid",
     "source_ref": "wa-ecology-cca-allowances",
     "unit": "MWh",
     "value": 22985346.0
    },
    "load_source": "UTC Docket UE-220797 Revised 07/12/23",
    "load_source_url": "https://www.utc.wa.gov/casedocket/2022/220797/docsets",
    "method": "Archive",
    "note": null,
    "supply_shares": [
     {
      "key": "gas",
      "label": "Natural gas",
      "mwh": 8637090.518271284,
      "share": 0.3758
     },
     {
      "key": "renewable_nonemitting",
      "label": "Renewable or non-emitting",
      "mwh": 11632960.0,
      "share": 0.5061
     },
     {
      "key": "coal",
      "label": "Coal",
      "mwh": 2715295.3673,
      "share": 0.1181
     }
    ],
    "supply_source": "See Demand Source",
    "supply_source_url": null,
    "utility_type": "IOU",
    "utility_type_label": "Investor-owned utility",
    "year": 2023
   },
   {
    "adjustments": [],
    "allowances": {
     "basis": "Ecology's Electric Utility Allowance Allocation Schedule under WAC 173-446-230: allowances allocated at no cost to a CETA-obligated electric utility for the calendar year, one allowance = one metric ton of CO2 equivalent. An allocation computed from Ecology's forecast of the utility's Washington retail load and resource supply, not measured emissions and not a cap on the utility",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "org:eia:15500#cca_no_cost_allowances_tco2e@2024",
     "label": "No-cost carbon allowances",
     "locator": "sheet AllowanceAllocation; Puget Sound Energy; 2024",
     "maturity": "final",
     "method": "direct",
     "metric": "cca_no_cost_allowances_tco2e",
     "missing_reason": null,
     "note": null,
     "period": {
      "hours": null,
      "kind": "calendar_year",
      "period_end": "2025-01-01T00:00:00Z",
      "period_start": "2024-01-01T00:00:00Z",
      "year": 2024
     },
     "precision": 0,
     "quality": "valid",
     "source_ref": "wa-ecology-cca-allowances",
     "unit": "t CO2e",
     "value": 6003582.0
    },
    "forecast_load": {
     "basis": "Forecasted Retail Load in Ecology's allocation workbook: the load forecast the no-cost allowance allocation was computed from, taken from the utility's own filing (CEIP, IRP, supplemental forecast or BPA rate-case billing determinants). A forecast for one regulatory purpose, not a measurement of sales",
     "coverage": null,
     "denominator": null,
     "evidence": "modeled",
     "fact_id": "org:eia:15500#cca_forecast_retail_load_mwh@2024",
     "label": "Washington retail load, Ecology's allocation forecast",
     "locator": "sheet DataCalcs; Puget Sound Energy; 2024",
     "maturity": "final",
     "method": "direct",
     "metric": "cca_forecast_retail_load_mwh",
     "missing_reason": null,
     "note": "Ecology's load forecast for the allocation, from UTC Docket UE-220797 Revised 07/12/23",
     "period": {
      "hours": null,
      "kind": "calendar_year",
      "period_end": "2025-01-01T00:00:00Z",
      "period_start": "2024-01-01T00:00:00Z",
      "year": 2024
     },
     "precision": 0,
     "quality": "valid",
     "source_ref": "wa-ecology-cca-allowances",
     "unit": "MWh",
     "value": 23090114.0
    },
    "load_source": "UTC Docket UE-220797 Revised 07/12/23",
    "load_source_url": "https://www.utc.wa.gov/casedocket/2022/220797/docsets",
    "method": "Archive",
    "note": null,
    "supply_shares": [
     {
      "key": "gas",
      "label": "Natural gas",
      "mwh": 7609317.795847148,
      "share": 0.3295
     },
     {
      "key": "renewable_nonemitting",
      "label": "Renewable or non-emitting",
      "mwh": 12945951.0,
      "share": 0.5607
     },
     {
      "key": "coal",
      "label": "Coal",
      "mwh": 2534845.2114,
      "share": 0.1098
     }
    ],
    "supply_source": "See Demand Source",
    "supply_source_url": null,
    "utility_type": "IOU",
    "utility_type_label": "Investor-owned utility",
    "year": 2024
   },
   {
    "adjustments": [],
    "allowances": {
     "basis": "Ecology's Electric Utility Allowance Allocation Schedule under WAC 173-446-230: allowances allocated at no cost to a CETA-obligated electric utility for the calendar year, one allowance = one metric ton of CO2 equivalent. An allocation computed from Ecology's forecast of the utility's Washington retail load and resource supply, not measured emissions and not a cap on the utility",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "org:eia:15500#cca_no_cost_allowances_tco2e@2025",
     "label": "No-cost carbon allowances",
     "locator": "sheet AllowanceAllocation; Puget Sound Energy; 2025",
     "maturity": "final",
     "method": "direct",
     "metric": "cca_no_cost_allowances_tco2e",
     "missing_reason": null,
     "note": null,
     "period": {
      "hours": null,
      "kind": "calendar_year",
      "period_end": "2026-01-01T00:00:00Z",
      "period_start": "2025-01-01T00:00:00Z",
      "year": 2025
     },
     "precision": 0,
     "quality": "valid",
     "source_ref": "wa-ecology-cca-allowances",
     "unit": "t CO2e",
     "value": 5561609.0
    },
    "forecast_load": {
     "basis": "Forecasted Retail Load in Ecology's allocation workbook: the load forecast the no-cost allowance allocation was computed from, taken from the utility's own filing (CEIP, IRP, supplemental forecast or BPA rate-case billing determinants). A forecast for one regulatory purpose, not a measurement of sales",
     "coverage": null,
     "denominator": null,
     "evidence": "modeled",
     "fact_id": "org:eia:15500#cca_forecast_retail_load_mwh@2025",
     "label": "Washington retail load, Ecology's allocation forecast",
     "locator": "sheet DataCalcs; Puget Sound Energy; 2025",
     "maturity": "final",
     "method": "direct",
     "metric": "cca_forecast_retail_load_mwh",
     "missing_reason": null,
     "note": "Ecology's load forecast for the allocation, from UTC Docket UE-220797 Revised 07/12/23",
     "period": {
      "hours": null,
      "kind": "calendar_year",
      "period_end": "2026-01-01T00:00:00Z",
      "period_start": "2025-01-01T00:00:00Z",
      "year": 2025
     },
     "precision": 0,
     "quality": "valid",
     "source_ref": "wa-ecology-cca-allowances",
     "unit": "MWh",
     "value": 23193531.0
    },
    "load_source": "UTC Docket UE-220797 Revised 07/12/23",
    "load_source_url": "https://www.utc.wa.gov/casedocket/2022/220797/docsets",
    "method": "IOU",
    "note": null,
    "supply_shares": [
     {
      "key": "gas",
      "label": "Natural gas",
      "mwh": 6663730.406788124,
      "share": 0.2873
     },
     {
      "key": "renewable_nonemitting",
      "label": "Renewable or non-emitting",
      "mwh": 14023469.0,
      "share": 0.6046
     },
     {
      "key": "coal",
      "label": "Coal",
      "mwh": 2506331.3035999998,
      "share": 0.1081
     }
    ],
    "supply_source": "See Load Source",
    "supply_source_url": null,
    "utility_type": "IOU",
    "utility_type_label": "Investor-owned utility",
    "year": 2025
   },
   {
    "adjustments": [
     {
      "key": "other",
      "label": "Other",
      "tco2e": -183163.0
     }
    ],
    "allowances": {
     "basis": "Ecology's Electric Utility Allowance Allocation Schedule under WAC 173-446-230: allowances allocated at no cost to a CETA-obligated electric utility for the calendar year, one allowance = one metric ton of CO2 equivalent. An allocation computed from Ecology's forecast of the utility's Washington retail load and resource supply, not measured emissions and not a cap on the utility",
     "coverage": null,
     "denominator": null,
     "evidence": "reported",
     "fact_id": "org:eia:15500#cca_no_cost_allowances_tco2e@2026",
     "label": "No-cost carbon allowances",
     "locator": "sheet AllowanceAllocation; Puget Sound Energy; 2026",
     "maturity": "final",
     "method": "direct",
     "metric": "cca_no_cost_allowances_tco2e",
     "missing_reason": null,
     "note": null,
     "period": {
      "hours": null,
      "kind": "calendar_year",
      "period_end": "2027-01-01T00:00:00Z",
      "period_start": "2026-01-01T00:00:00Z",
      "year": 2026
     },
     "precision": 0,
     "quality": "valid",
     "source_ref": "wa-ecology-cca-allowances",
     "unit": "t CO2e",
     "value": 4652168.0
    },
    "forecast_load": {
     "basis": "Forecasted Retail Load in Ecology's allocation workbook: the load forecast the no-cost allowance allocation was computed from, taken from the utility's own filing (CEIP, IRP, supplemental forecast or BPA rate-case billing determinants). A forecast for one regulatory purpose, not a measurement of sales",
     "coverage": null,
     "denominator": null,
     "evidence": "modeled",
     "fact_id": "org:eia:15500#cca_forecast_retail_load_mwh@2026",
     "label": "Washington retail load, Ecology's allocation forecast",
     "locator": "sheet DataCalcs; Puget Sound Energy; 2026",
     "maturity": "final",
     "method": "direct",
     "metric": "cca_forecast_retail_load_mwh",
     "missing_reason": null,
     "note": "Ecology's load forecast for the allocation, from UTC Docket UE-220797 Revised 04/21/2025",
     "period": {
      "hours": null,
      "kind": "calendar_year",
      "period_end": "2027-01-01T00:00:00Z",
      "period_start": "2026-01-01T00:00:00Z",
      "year": 2026
     },
     "precision": 0,
     "quality": "valid",
     "source_ref": "wa-ecology-cca-allowances",
     "unit": "MWh",
     "value": 22934869.2199251
    },
    "load_source": "UTC Docket UE-220797 Revised 04/21/2025",
    "load_source_url": "https://www.utc.wa.gov/casedocket/2022/220797/docsets",
    "method": "IOU",
    "note": "ECY adjusted forecast submitted in 2025 to appropriately account for PURPA and voluntary clean energy MWhs and system losses. Forecast adjustment confirmed by PSE. \"Allocation adjustment other\" represents an adjustment to Puget Sound Energy’s vintage 2026 no-cost allowances accounting for calendar year 2024 pursuant to WAC 173-446-230(2)(g).",
    "supply_shares": [
     {
      "key": "gas",
      "label": "Natural gas",
      "mwh": 10777412.626000002,
      "share": 0.4699
     },
     {
      "key": "renewable_nonemitting",
      "label": "Renewable or non-emitting",
      "mwh": 11830579.71078656,
      "share": 0.5158
     },
     {
      "key": "unspecified",
      "label": "Unspecified market purchases",
      "mwh": 326876.8831385365,
      "share": 0.0143
     }
    ],
    "supply_source": "See Load Source",
    "supply_source_url": null,
    "utility_type": "IOU",
    "utility_type_label": "Investor-owned utility",
    "year": 2026
   }
  ]
 },
 "citation_path": "citations/org~eia~15500.html",
 "consumer_owned": false,
 "coverage": {
  "note": "Ownership, operation and retail sales are separate roles; none is a supply relationship",
  "plants_operated": 19,
  "plants_owned": 17,
  "retail_rows": 10,
  "territories_reviewed": 1
 },
 "disclosed_supply": {
  "attribution": "Washington State Department of Commerce, Fuel Mix Disclosure CY2024 (report 2026-02-05), data extract",
  "available": true,
  "bpa_share": 0.026,
  "categories": [
   {
    "bpa_mwh": 0.0,
    "category": "Natural Gas",
    "mwh": 6620495.0,
    "plant_claims_mwh": 6620495.0,
    "resource_group": "gas",
    "share": 0.3204,
    "unspecified_mwh": 0.0
   },
   {
    "bpa_mwh": 403980.0,
    "category": "Hydro",
    "mwh": 5847448.0,
    "plant_claims_mwh": 5443468.0,
    "resource_group": "hydro",
    "share": 0.2829,
    "unspecified_mwh": 0.0
   },
   {
    "bpa_mwh": 0.0,
    "category": "Wind",
    "mwh": 4099762.0,
    "plant_claims_mwh": 4099762.0,
    "resource_group": "wind",
    "share": 0.1984,
    "unspecified_mwh": 0.0
   },
   {
    "bpa_mwh": 0.0,
    "category": "Coal",
    "mwh": 3733769.0,
    "plant_claims_mwh": 3733769.0,
    "resource_group": "coal",
    "share": 0.1807,
    "unspecified_mwh": 0.0
   },
   {
    "bpa_mwh": 0.0,
    "category": "Biomass",
    "mwh": 101435.0,
    "plant_claims_mwh": 101435.0,
    "resource_group": "waste",
    "share": 0.0049,
    "unspecified_mwh": 0.0
   },
   {
    "bpa_mwh": 0.0,
    "category": "Other Non-Biogenic",
    "mwh": 99920.0,
    "plant_claims_mwh": 99920.0,
    "resource_group": "other",
    "share": 0.0048,
    "unspecified_mwh": 0.0
   },
   {
    "bpa_mwh": 69208.0,
    "category": "Nuclear",
    "mwh": 69208.0,
    "plant_claims_mwh": 0.0,
    "resource_group": "nuclear",
    "share": 0.0033,
    "unspecified_mwh": 0.0
   },
   {
    "bpa_mwh": 63306.0,
    "category": "Market",
    "mwh": 63306.0,
    "plant_claims_mwh": 0.0,
    "resource_group": "unspecified",
    "share": 0.0031,
    "unspecified_mwh": 63306.0
   },
   {
    "bpa_mwh": 0.0,
    "category": "Petroleum",
    "mwh": 30816.0,
    "plant_claims_mwh": 30816.0,
    "resource_group": "oil",
    "share": 0.0015,
    "unspecified_mwh": 0.0
   },
   {
    "bpa_mwh": 0.0,
    "category": "Solar",
    "mwh": 278.0,
    "plant_claims_mwh": 278.0,
    "resource_group": "solar",
    "share": 0.0,
    "unspecified_mwh": 0.0
   }
  ],
  "claimant": {
   "id": 90,
   "link_basis": "name_exact_normalized",
   "name": "Puget Sound Energy"
  },
  "download_from_publisher": {
   "label": "Commerce's own Fuel Mix Disclosure folder (reports and data extracts, CY2014–CY2024)",
   "note": "The atlas shows each claimant's figures with attribution on its organization and plant pages; it publishes no copy of the extracts and no table of their rows.",
   "url": "https://deptofcommerce.app.box.com/s/l9sqx4bcfnko3omrpk4tv8n0vbzcvsdz"
  },
  "facts": [
   {
    "basis": "Washington Fuel Mix Disclosure: total MWh across fuel categories for the claimant's Washington customers, including line losses, for the report year",
    "coverage": {
     "eligible": 15,
     "included": 15,
     "unit": "native rows"
    },
    "denominator": null,
    "evidence": "reported",
    "fact_id": "org:eia:15500#disclosed_sales_mwh@2024",
    "label": "Washington retail sales disclosed",
    "locator": "Claimant ID=90",
    "maturity": "final",
    "method": "direct",
    "metric": "disclosed_sales_mwh",
    "missing_reason": null,
    "note": "Washington customers only for multi-state utilities; includes line losses",
    "period": {
     "hours": null,
     "kind": "calendar_year",
     "period_end": "2025-01-01T00:00:00Z",
     "period_start": "2024-01-01T00:00:00Z",
     "year": 2024
    },
    "precision": 0,
    "quality": "valid",
    "source_ref": "wa-fmd-2024-by-category",
    "unit": "MWh",
    "value": 20666437.0
   }
  ],
  "history": [
   {
    "available": true,
    "bpa_share": 0.0242,
    "categories": [
     {
      "category": "Market",
      "mwh": 7720681.0,
      "resource_group": "unspecified",
      "share": 0.3529
     },
     {
      "category": "Hydro",
      "mwh": 4855209.0,
      "resource_group": "hydro",
      "share": 0.2218
     },
     {
      "category": "Coal",
      "mwh": 4570412.0,
      "resource_group": "coal",
      "share": 0.2088
     },
     {
      "category": "Natural Gas",
      "mwh": 4090422.0,
      "resource_group": "gas",
      "share": 0.1869
     },
     {
      "category": "Wind",
      "mwh": 584737.0,
      "resource_group": "wind",
      "share": 0.0267
     },
     {
      "category": "Nuclear",
      "mwh": 55105.0,
      "resource_group": "nuclear",
      "share": 0.0025
     },
     {
      "category": "Petroleum",
      "mwh": 9288.0,
      "resource_group": "oil",
      "share": 0.0004
     },
     {
      "category": "Biomass",
      "mwh": 529.0,
      "resource_group": "waste",
      "share": 0.0
     },
     {
      "category": "Solar",
      "mwh": 179.0,
      "resource_group": "solar",
      "share": 0.0
     }
    ],
    "claimant": {
     "id": 90,
     "link_basis": "name_exact_normalized",
     "name": "Puget Sound Energy"
    },
    "facts": [
     {
      "basis": "Washington Fuel Mix Disclosure: total MWh across fuel categories for the claimant's Washington customers, including line losses, for the report year",
      "coverage": {
       "eligible": 15,
       "included": 15,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500#disclosed_sales_mwh@2014",
      "label": "Washington retail sales disclosed",
      "locator": "Claimant ID=90",
      "maturity": "final",
      "method": "direct",
      "metric": "disclosed_sales_mwh",
      "missing_reason": null,
      "note": "Washington customers only for multi-state utilities; includes line losses; Commerce's restatement, not the disclosure published for the year",
      "period": {
       "hours": null,
       "kind": "calendar_year",
       "period_end": "2015-01-01T00:00:00Z",
       "period_start": "2014-01-01T00:00:00Z",
       "year": 2014
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "wa-fmd-2014-by-category",
      "unit": "MWh",
      "value": 21886562.0
     }
    ],
    "method_era": "restated_pre_2018",
    "report_year": 2014,
    "source_ref": "wa-fmd-2014-by-category",
    "unspecified_share": 0.3528
   },
   {
    "available": true,
    "bpa_share": 0.0224,
    "categories": [
     {
      "category": "Coal",
      "mwh": 6052572.0,
      "resource_group": "coal",
      "share": 0.2798
     },
     {
      "category": "Natural Gas",
      "mwh": 5745838.0,
      "resource_group": "gas",
      "share": 0.2657
     },
     {
      "category": "Hydro",
      "mwh": 4554044.0,
      "resource_group": "hydro",
      "share": 0.2106
     },
     {
      "category": "Market",
      "mwh": 4374020.0,
      "resource_group": "unspecified",
      "share": 0.2022
     },
     {
      "category": "Wind",
      "mwh": 842578.0,
      "resource_group": "wind",
      "share": 0.039
     },
     {
      "category": "Nuclear",
      "mwh": 49007.0,
      "resource_group": "nuclear",
      "share": 0.0023
     },
     {
      "category": "Petroleum",
      "mwh": 7966.0,
      "resource_group": "oil",
      "share": 0.0004
     },
     {
      "category": "Biomass",
      "mwh": 644.0,
      "resource_group": "waste",
      "share": 0.0
     },
     {
      "category": "Solar",
      "mwh": 626.0,
      "resource_group": "solar",
      "share": 0.0
     },
     {
      "category": "Other Biogenic",
      "mwh": 549.0,
      "resource_group": "other",
      "share": 0.0
     },
     {
      "category": "Biogas",
      "mwh": 2.0,
      "resource_group": "waste",
      "share": 0.0
     }
    ],
    "claimant": {
     "id": 90,
     "link_basis": "name_exact_normalized",
     "name": "Puget Sound Energy"
    },
    "facts": [
     {
      "basis": "Washington Fuel Mix Disclosure: total MWh across fuel categories for the claimant's Washington customers, including line losses, for the report year",
      "coverage": {
       "eligible": 15,
       "included": 15,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500#disclosed_sales_mwh@2015",
      "label": "Washington retail sales disclosed",
      "locator": "Claimant ID=90",
      "maturity": "final",
      "method": "direct",
      "metric": "disclosed_sales_mwh",
      "missing_reason": null,
      "note": "Washington customers only for multi-state utilities; includes line losses; Commerce's restatement, not the disclosure published for the year",
      "period": {
       "hours": null,
       "kind": "calendar_year",
       "period_end": "2016-01-01T00:00:00Z",
       "period_start": "2015-01-01T00:00:00Z",
       "year": 2015
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "wa-fmd-2015-by-category",
      "unit": "MWh",
      "value": 21627846.0
     }
    ],
    "method_era": "restated_pre_2018",
    "report_year": 2015,
    "source_ref": "wa-fmd-2015-by-category",
    "unspecified_share": 0.2022
   },
   {
    "available": true,
    "bpa_share": 0.0356,
    "categories": [
     {
      "category": "Coal",
      "mwh": 6939595.0,
      "resource_group": "coal",
      "share": 0.3215
     },
     {
      "category": "Hydro",
      "mwh": 5205674.0,
      "resource_group": "hydro",
      "share": 0.2412
     },
     {
      "category": "Natural Gas",
      "mwh": 4083015.0,
      "resource_group": "gas",
      "share": 0.1892
     },
     {
      "category": "Market",
      "mwh": 3224966.0,
      "resource_group": "unspecified",
      "share": 0.1494
     },
     {
      "category": "Wind",
      "mwh": 1999840.0,
      "resource_group": "wind",
      "share": 0.0927
     },
     {
      "category": "Nuclear",
      "mwh": 85187.0,
      "resource_group": "nuclear",
      "share": 0.0039
     },
     {
      "category": "Biogas",
      "mwh": 32627.0,
      "resource_group": "waste",
      "share": 0.0015
     },
     {
      "category": "Petroleum",
      "mwh": 12111.0,
      "resource_group": "oil",
      "share": 0.0006
     },
     {
      "category": "Solar",
      "mwh": 1030.0,
      "resource_group": "solar",
      "share": 0.0
     },
     {
      "category": "Biomass",
      "mwh": 416.0,
      "resource_group": "waste",
      "share": 0.0
     },
     {
      "category": "Other Biogenic",
      "mwh": 197.0,
      "resource_group": "other",
      "share": 0.0
     }
    ],
    "claimant": {
     "id": 90,
     "link_basis": "name_exact_normalized",
     "name": "Puget Sound Energy"
    },
    "facts": [
     {
      "basis": "Washington Fuel Mix Disclosure: total MWh across fuel categories for the claimant's Washington customers, including line losses, for the report year",
      "coverage": {
       "eligible": 15,
       "included": 15,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500#disclosed_sales_mwh@2016",
      "label": "Washington retail sales disclosed",
      "locator": "Claimant ID=90",
      "maturity": "final",
      "method": "direct",
      "metric": "disclosed_sales_mwh",
      "missing_reason": null,
      "note": "Washington customers only for multi-state utilities; includes line losses; Commerce's restatement, not the disclosure published for the year",
      "period": {
       "hours": null,
       "kind": "calendar_year",
       "period_end": "2017-01-01T00:00:00Z",
       "period_start": "2016-01-01T00:00:00Z",
       "year": 2016
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "wa-fmd-2016-by-category",
      "unit": "MWh",
      "value": 21584658.0
     }
    ],
    "method_era": "restated_pre_2018",
    "report_year": 2016,
    "source_ref": "wa-fmd-2016-by-category",
    "unspecified_share": 0.1494
   },
   {
    "available": true,
    "bpa_share": 0.0249,
    "categories": [
     {
      "category": "Coal",
      "mwh": 7645766.0,
      "resource_group": "coal",
      "share": 0.3408
     },
     {
      "category": "Hydro",
      "mwh": 4912099.0,
      "resource_group": "hydro",
      "share": 0.2189
     },
     {
      "category": "Market",
      "mwh": 4705900.0,
      "resource_group": "unspecified",
      "share": 0.2098
     },
     {
      "category": "Natural Gas",
      "mwh": 3753271.0,
      "resource_group": "gas",
      "share": 0.1673
     },
     {
      "category": "Wind",
      "mwh": 1356385.0,
      "resource_group": "wind",
      "share": 0.0605
     },
     {
      "category": "Nuclear",
      "mwh": 49044.0,
      "resource_group": "nuclear",
      "share": 0.0022
     },
     {
      "category": "Petroleum",
      "mwh": 11946.0,
      "resource_group": "oil",
      "share": 0.0005
     },
     {
      "category": "Solar",
      "mwh": 879.0,
      "resource_group": "solar",
      "share": 0.0
     },
     {
      "category": "Other Biogenic",
      "mwh": 6.0,
      "resource_group": "other",
      "share": 0.0
     }
    ],
    "claimant": {
     "id": 90,
     "link_basis": "name_exact_normalized",
     "name": "Puget Sound Energy"
    },
    "facts": [
     {
      "basis": "Washington Fuel Mix Disclosure: total MWh across fuel categories for the claimant's Washington customers, including line losses, for the report year",
      "coverage": {
       "eligible": 15,
       "included": 15,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500#disclosed_sales_mwh@2017",
      "label": "Washington retail sales disclosed",
      "locator": "Claimant ID=90",
      "maturity": "final",
      "method": "direct",
      "metric": "disclosed_sales_mwh",
      "missing_reason": null,
      "note": "Washington customers only for multi-state utilities; includes line losses; Commerce's restatement, not the disclosure published for the year",
      "period": {
       "hours": null,
       "kind": "calendar_year",
       "period_end": "2018-01-01T00:00:00Z",
       "period_start": "2017-01-01T00:00:00Z",
       "year": 2017
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "wa-fmd-2017-by-category",
      "unit": "MWh",
      "value": 22435296.0
     }
    ],
    "method_era": "restated_pre_2018",
    "report_year": 2017,
    "source_ref": "wa-fmd-2017-by-category",
    "unspecified_share": 0.2098
   },
   {
    "available": true,
    "bpa_share": 0.0339,
    "categories": [
     {
      "category": "Coal",
      "mwh": 6932757.0,
      "resource_group": "coal",
      "share": 0.3118
     },
     {
      "category": "Hydro",
      "mwh": 4956837.0,
      "resource_group": "hydro",
      "share": 0.2229
     },
     {
      "category": "Market",
      "mwh": 4352748.0,
      "resource_group": "unspecified",
      "share": 0.1958
     },
     {
      "category": "Natural Gas",
      "mwh": 3832936.0,
      "resource_group": "gas",
      "share": 0.1724
     },
     {
      "category": "Wind",
      "mwh": 1869790.0,
      "resource_group": "wind",
      "share": 0.0841
     },
     {
      "category": "Solar",
      "mwh": 149638.0,
      "resource_group": "solar",
      "share": 0.0067
     },
     {
      "category": "Nuclear",
      "mwh": 80467.0,
      "resource_group": "nuclear",
      "share": 0.0036
     },
     {
      "category": "Biogas",
      "mwh": 31708.0,
      "resource_group": "waste",
      "share": 0.0014
     },
     {
      "category": "Petroleum",
      "mwh": 13107.0,
      "resource_group": "oil",
      "share": 0.0006
     },
     {
      "category": "Biomass",
      "mwh": 10143.0,
      "resource_group": "waste",
      "share": 0.0005
     },
     {
      "category": "Geothermal",
      "mwh": 3540.0,
      "resource_group": "geothermal",
      "share": 0.0002
     }
    ],
    "claimant": {
     "id": 90,
     "link_basis": "name_exact_normalized",
     "name": "Puget Sound Energy"
    },
    "facts": [
     {
      "basis": "Washington Fuel Mix Disclosure: total MWh across fuel categories for the claimant's Washington customers, including line losses, for the report year",
      "coverage": {
       "eligible": 15,
       "included": 15,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500#disclosed_sales_mwh@2018",
      "label": "Washington retail sales disclosed",
      "locator": "Claimant ID=90",
      "maturity": "final",
      "method": "direct",
      "metric": "disclosed_sales_mwh",
      "missing_reason": null,
      "note": "Washington customers only for multi-state utilities; includes line losses",
      "period": {
       "hours": null,
       "kind": "calendar_year",
       "period_end": "2019-01-01T00:00:00Z",
       "period_start": "2018-01-01T00:00:00Z",
       "year": 2018
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "wa-fmd-2018-by-category",
      "unit": "MWh",
      "value": 22233671.0
     }
    ],
    "method_era": "from_2018",
    "report_year": 2018,
    "source_ref": "wa-fmd-2018-by-category",
    "unspecified_share": 0.1958
   },
   {
    "available": true,
    "bpa_share": 0.0235,
    "categories": [
     {
      "category": "Coal",
      "mwh": 7082124.0,
      "resource_group": "coal",
      "share": 0.3198
     },
     {
      "category": "Natural Gas",
      "mwh": 6180741.0,
      "resource_group": "gas",
      "share": 0.2792
     },
     {
      "category": "Hydro",
      "mwh": 3802122.0,
      "resource_group": "hydro",
      "share": 0.1717
     },
     {
      "category": "Market",
      "mwh": 2937304.0,
      "resource_group": "unspecified",
      "share": 0.1327
     },
     {
      "category": "Wind",
      "mwh": 1827750.0,
      "resource_group": "wind",
      "share": 0.0826
     },
     {
      "category": "Solar",
      "mwh": 193072.0,
      "resource_group": "solar",
      "share": 0.0087
     },
     {
      "category": "Nuclear",
      "mwh": 59591.0,
      "resource_group": "nuclear",
      "share": 0.0027
     },
     {
      "category": "Biogas",
      "mwh": 31058.0,
      "resource_group": "waste",
      "share": 0.0014
     },
     {
      "category": "Biomass",
      "mwh": 13108.0,
      "resource_group": "waste",
      "share": 0.0006
     },
     {
      "category": "Petroleum",
      "mwh": 8860.0,
      "resource_group": "oil",
      "share": 0.0004
     },
     {
      "category": "Geothermal",
      "mwh": 3660.0,
      "resource_group": "geothermal",
      "share": 0.0002
     }
    ],
    "claimant": {
     "id": 90,
     "link_basis": "name_exact_normalized",
     "name": "Puget Sound Energy"
    },
    "facts": [
     {
      "basis": "Washington Fuel Mix Disclosure: total MWh across fuel categories for the claimant's Washington customers, including line losses, for the report year",
      "coverage": {
       "eligible": 15,
       "included": 15,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500#disclosed_sales_mwh@2019",
      "label": "Washington retail sales disclosed",
      "locator": "Claimant ID=90",
      "maturity": "final",
      "method": "direct",
      "metric": "disclosed_sales_mwh",
      "missing_reason": null,
      "note": "Washington customers only for multi-state utilities; includes line losses",
      "period": {
       "hours": null,
       "kind": "calendar_year",
       "period_end": "2020-01-01T00:00:00Z",
       "period_start": "2019-01-01T00:00:00Z",
       "year": 2019
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "wa-fmd-2019-by-category",
      "unit": "MWh",
      "value": 22139390.0
     }
    ],
    "method_era": "from_2018",
    "report_year": 2019,
    "source_ref": "wa-fmd-2019-by-category",
    "unspecified_share": 0.1327
   },
   {
    "available": true,
    "bpa_share": 0.0172,
    "categories": [
     {
      "category": "Natural Gas",
      "mwh": 5869992.0,
      "resource_group": "gas",
      "share": 0.2704
     },
     {
      "category": "Hydro",
      "mwh": 5234658.0,
      "resource_group": "hydro",
      "share": 0.2412
     },
     {
      "category": "Coal",
      "mwh": 4984651.0,
      "resource_group": "coal",
      "share": 0.2296
     },
     {
      "category": "Market",
      "mwh": 3053442.0,
      "resource_group": "unspecified",
      "share": 0.1407
     },
     {
      "category": "Wind",
      "mwh": 2282111.0,
      "resource_group": "wind",
      "share": 0.1051
     },
     {
      "category": "Solar",
      "mwh": 206950.0,
      "resource_group": "solar",
      "share": 0.0095
     },
     {
      "category": "Nuclear",
      "mwh": 40693.0,
      "resource_group": "nuclear",
      "share": 0.0019
     },
     {
      "category": "Biogas",
      "mwh": 19362.0,
      "resource_group": "waste",
      "share": 0.0009
     },
     {
      "category": "Petroleum",
      "mwh": 9430.0,
      "resource_group": "oil",
      "share": 0.0004
     },
     {
      "category": "Geothermal",
      "mwh": 3500.0,
      "resource_group": "geothermal",
      "share": 0.0002
     },
     {
      "category": "Biomass",
      "mwh": 2087.0,
      "resource_group": "waste",
      "share": 0.0001
     }
    ],
    "claimant": {
     "id": 90,
     "link_basis": "name_exact_normalized",
     "name": "Puget Sound Energy"
    },
    "facts": [
     {
      "basis": "Washington Fuel Mix Disclosure: total MWh across fuel categories for the claimant's Washington customers, including line losses, for the report year",
      "coverage": {
       "eligible": 15,
       "included": 15,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500#disclosed_sales_mwh@2020",
      "label": "Washington retail sales disclosed",
      "locator": "Claimant ID=90",
      "maturity": "final",
      "method": "direct",
      "metric": "disclosed_sales_mwh",
      "missing_reason": null,
      "note": "Washington customers only for multi-state utilities; includes line losses",
      "period": {
       "hours": null,
       "kind": "calendar_year",
       "period_end": "2021-01-01T00:00:00Z",
       "period_start": "2020-01-01T00:00:00Z",
       "year": 2020
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "wa-fmd-2020-by-category",
      "unit": "MWh",
      "value": 21706876.0
     }
    ],
    "method_era": "from_2018",
    "report_year": 2020,
    "source_ref": "wa-fmd-2020-by-category",
    "unspecified_share": 0.1407
   },
   {
    "available": true,
    "bpa_share": 0.0427,
    "categories": [
     {
      "category": "Natural Gas",
      "mwh": 6752499.0,
      "resource_group": "gas",
      "share": 0.3048
     },
     {
      "category": "Coal",
      "mwh": 5425385.0,
      "resource_group": "coal",
      "share": 0.245
     },
     {
      "category": "Hydro",
      "mwh": 5321829.0,
      "resource_group": "hydro",
      "share": 0.2403
     },
     {
      "category": "Wind",
      "mwh": 2298268.0,
      "resource_group": "wind",
      "share": 0.1038
     },
     {
      "category": "Market",
      "mwh": 2030136.0,
      "resource_group": "unspecified",
      "share": 0.0917
     },
     {
      "category": "Solar",
      "mwh": 180141.0,
      "resource_group": "solar",
      "share": 0.0081
     },
     {
      "category": "Nuclear",
      "mwh": 103131.0,
      "resource_group": "nuclear",
      "share": 0.0047
     },
     {
      "category": "Biogas",
      "mwh": 15731.0,
      "resource_group": "waste",
      "share": 0.0007
     },
     {
      "category": "Petroleum",
      "mwh": 11837.0,
      "resource_group": "oil",
      "share": 0.0005
     },
     {
      "category": "Geothermal",
      "mwh": 5000.0,
      "resource_group": "geothermal",
      "share": 0.0002
     },
     {
      "category": "Biomass",
      "mwh": 3700.0,
      "resource_group": "waste",
      "share": 0.0002
     }
    ],
    "claimant": {
     "id": 90,
     "link_basis": "name_exact_normalized",
     "name": "Puget Sound Energy"
    },
    "facts": [
     {
      "basis": "Washington Fuel Mix Disclosure: total MWh across fuel categories for the claimant's Washington customers, including line losses, for the report year",
      "coverage": {
       "eligible": 15,
       "included": 15,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500#disclosed_sales_mwh@2021",
      "label": "Washington retail sales disclosed",
      "locator": "Claimant ID=90",
      "maturity": "final",
      "method": "direct",
      "metric": "disclosed_sales_mwh",
      "missing_reason": null,
      "note": "Washington customers only for multi-state utilities; includes line losses",
      "period": {
       "hours": null,
       "kind": "calendar_year",
       "period_end": "2022-01-01T00:00:00Z",
       "period_start": "2021-01-01T00:00:00Z",
       "year": 2021
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "wa-fmd-2021-by-category",
      "unit": "MWh",
      "value": 22147657.0
     }
    ],
    "method_era": "from_2018",
    "report_year": 2021,
    "source_ref": "wa-fmd-2021-by-category",
    "unspecified_share": 0.0917
   },
   {
    "available": true,
    "bpa_share": 0.0317,
    "categories": [
     {
      "category": "Hydro",
      "mwh": 6003382.0,
      "resource_group": "hydro",
      "share": 0.2653
     },
     {
      "category": "Coal",
      "mwh": 5226971.0,
      "resource_group": "coal",
      "share": 0.231
     },
     {
      "category": "Natural Gas",
      "mwh": 5199138.0,
      "resource_group": "gas",
      "share": 0.2297
     },
     {
      "category": "Wind",
      "mwh": 3559155.0,
      "resource_group": "wind",
      "share": 0.1573
     },
     {
      "category": "Market",
      "mwh": 2211216.0,
      "resource_group": "unspecified",
      "share": 0.0977
     },
     {
      "category": "Solar",
      "mwh": 176020.0,
      "resource_group": "solar",
      "share": 0.0078
     },
     {
      "category": "Biomass",
      "mwh": 97985.0,
      "resource_group": "waste",
      "share": 0.0043
     },
     {
      "category": "Nuclear",
      "mwh": 78749.0,
      "resource_group": "nuclear",
      "share": 0.0035
     },
     {
      "category": "Biogas",
      "mwh": 49598.0,
      "resource_group": "waste",
      "share": 0.0022
     },
     {
      "category": "Petroleum",
      "mwh": 22501.0,
      "resource_group": "oil",
      "share": 0.001
     },
     {
      "category": "Geothermal",
      "mwh": 5000.0,
      "resource_group": "geothermal",
      "share": 0.0002
     }
    ],
    "claimant": {
     "id": 90,
     "link_basis": "name_exact_normalized",
     "name": "Puget Sound Energy"
    },
    "facts": [
     {
      "basis": "Washington Fuel Mix Disclosure: total MWh across fuel categories for the claimant's Washington customers, including line losses, for the report year",
      "coverage": {
       "eligible": 15,
       "included": 15,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500#disclosed_sales_mwh@2022",
      "label": "Washington retail sales disclosed",
      "locator": "Claimant ID=90",
      "maturity": "final",
      "method": "direct",
      "metric": "disclosed_sales_mwh",
      "missing_reason": null,
      "note": "Washington customers only for multi-state utilities; includes line losses",
      "period": {
       "hours": null,
       "kind": "calendar_year",
       "period_end": "2023-01-01T00:00:00Z",
       "period_start": "2022-01-01T00:00:00Z",
       "year": 2022
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "wa-fmd-2022-by-category",
      "unit": "MWh",
      "value": 22629715.0
     }
    ],
    "method_era": "from_2018",
    "report_year": 2022,
    "source_ref": "wa-fmd-2022-by-category",
    "unspecified_share": 0.0977
   },
   {
    "available": true,
    "bpa_share": 0.0173,
    "categories": [
     {
      "category": "Natural Gas",
      "mwh": 6224678.0,
      "resource_group": "gas",
      "share": 0.2992
     },
     {
      "category": "Hydro",
      "mwh": 6152717.0,
      "resource_group": "hydro",
      "share": 0.2957
     },
     {
      "category": "Wind",
      "mwh": 4494409.0,
      "resource_group": "wind",
      "share": 0.216
     },
     {
      "category": "Coal",
      "mwh": 3663321.0,
      "resource_group": "coal",
      "share": 0.1761
     },
     {
      "category": "Biomass",
      "mwh": 125738.0,
      "resource_group": "waste",
      "share": 0.006
     },
     {
      "category": "Other Non-Biogenic",
      "mwh": 50143.0,
      "resource_group": "other",
      "share": 0.0024
     },
     {
      "category": "Nuclear",
      "mwh": 40594.0,
      "resource_group": "nuclear",
      "share": 0.002
     },
     {
      "category": "Market",
      "mwh": 38712.0,
      "resource_group": "unspecified",
      "share": 0.0019
     },
     {
      "category": "Petroleum",
      "mwh": 13096.0,
      "resource_group": "oil",
      "share": 0.0006
     },
     {
      "category": "Solar",
      "mwh": 1271.0,
      "resource_group": "solar",
      "share": 0.0001
     },
     {
      "category": "Biogas",
      "mwh": 454.0,
      "resource_group": "waste",
      "share": 0.0
     }
    ],
    "claimant": {
     "id": 90,
     "link_basis": "name_exact_normalized",
     "name": "Puget Sound Energy"
    },
    "facts": [
     {
      "basis": "Washington Fuel Mix Disclosure: total MWh across fuel categories for the claimant's Washington customers, including line losses, for the report year",
      "coverage": {
       "eligible": 15,
       "included": 15,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500#disclosed_sales_mwh@2023",
      "label": "Washington retail sales disclosed",
      "locator": "Claimant ID=90",
      "maturity": "final",
      "method": "direct",
      "metric": "disclosed_sales_mwh",
      "missing_reason": null,
      "note": "Washington customers only for multi-state utilities; includes line losses",
      "period": {
       "hours": null,
       "kind": "calendar_year",
       "period_end": "2024-01-01T00:00:00Z",
       "period_start": "2023-01-01T00:00:00Z",
       "year": 2023
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "wa-fmd-2023-by-category",
      "unit": "MWh",
      "value": 20805133.0
     }
    ],
    "method_era": "from_2018",
    "report_year": 2023,
    "source_ref": "wa-fmd-2023-by-category",
    "unspecified_share": 0.0019
   },
   {
    "available": true,
    "bpa_share": 0.026,
    "categories": [
     {
      "category": "Natural Gas",
      "mwh": 6620495.0,
      "resource_group": "gas",
      "share": 0.3204
     },
     {
      "category": "Hydro",
      "mwh": 5847448.0,
      "resource_group": "hydro",
      "share": 0.2829
     },
     {
      "category": "Wind",
      "mwh": 4099762.0,
      "resource_group": "wind",
      "share": 0.1984
     },
     {
      "category": "Coal",
      "mwh": 3733769.0,
      "resource_group": "coal",
      "share": 0.1807
     },
     {
      "category": "Biomass",
      "mwh": 101435.0,
      "resource_group": "waste",
      "share": 0.0049
     },
     {
      "category": "Other Non-Biogenic",
      "mwh": 99920.0,
      "resource_group": "other",
      "share": 0.0048
     },
     {
      "category": "Nuclear",
      "mwh": 69208.0,
      "resource_group": "nuclear",
      "share": 0.0033
     },
     {
      "category": "Market",
      "mwh": 63306.0,
      "resource_group": "unspecified",
      "share": 0.0031
     },
     {
      "category": "Petroleum",
      "mwh": 30816.0,
      "resource_group": "oil",
      "share": 0.0015
     },
     {
      "category": "Solar",
      "mwh": 278.0,
      "resource_group": "solar",
      "share": 0.0
     }
    ],
    "claimant": {
     "id": 90,
     "link_basis": "name_exact_normalized",
     "name": "Puget Sound Energy"
    },
    "facts": [
     {
      "basis": "Washington Fuel Mix Disclosure: total MWh across fuel categories for the claimant's Washington customers, including line losses, for the report year",
      "coverage": {
       "eligible": 15,
       "included": 15,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500#disclosed_sales_mwh@2024",
      "label": "Washington retail sales disclosed",
      "locator": "Claimant ID=90",
      "maturity": "final",
      "method": "direct",
      "metric": "disclosed_sales_mwh",
      "missing_reason": null,
      "note": "Washington customers only for multi-state utilities; includes line losses",
      "period": {
       "hours": null,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "wa-fmd-2024-by-category",
      "unit": "MWh",
      "value": 20666437.0
     }
    ],
    "method_era": "from_2018",
    "report_year": 2024,
    "source_ref": "wa-fmd-2024-by-category",
    "unspecified_share": 0.0031
   }
  ],
  "history_note": "Each year as Commerce's fuel-mix system holds it: MWh and shares of the utility's Washington retail sales including line losses, never generation and never a compliance finding. Years before CY2018 are Commerce's restatement under the 2019 method, not the disclosure published for the year; no change is taken across that break.",
  "method_era": "from_2018",
  "method_eras": {
   "from_2018": {
    "document": "CY2022-Aggregate Fuel Mix Time Series.xlsx",
    "label": "CY2018 on",
    "locator": "Info!A10; Info!A16",
    "note": "Unspecified power is disclosed as its own category, as the statute has required since ESHB 1428 (2019); Commerce's statutory aggregate carries an unspecified row from CY2018.",
    "source_ref": "wa-fmd-2022-aggregate-time-series",
    "url": "https://deptofcommerce.app.box.com/s/l9sqx4bcfnko3omrpk4tv8n0vbzcvsdz/folder/368878833354"
   },
   "restated_pre_2018": {
    "document": "CY2022-Aggregate Fuel Mix Time Series.xlsx",
    "label": "Before CY2018: restated",
    "locator": "Info!A10; Info!A16",
    "note": "Commerce's current system run over what utilities reported for a year before CY2018. The disclosure published for that year followed the old law, which required Commerce to assign fuel shares to unspecified power; this run keeps unspecified power as its own Market category, and Commerce's statewide totals for these years differ from the statutory reports. Not the label customers received, and not comparable with CY2018 on.",
    "source_ref": "wa-fmd-2022-aggregate-time-series",
    "url": "https://deptofcommerce.app.box.com/s/l9sqx4bcfnko3omrpk4tv8n0vbzcvsdz/folder/368878833354"
   }
  },
  "note": "Categories and shares as Commerce computed them from declared resources, the BPA system mix (BPA's own mix applied to BPA deliveries, remainder unspecified) and unspecified purchases; a declared resource needs ownership or an auditable contract and its REC; renewable power without the REC counts as unspecified. Not an emissions accounting.",
  "plant_claims": [
   {
    "category": "Coal",
    "claim_type": "Utility Specified",
    "fuel_type": "Subbituminous Coal",
    "mwh": 2250331.0,
    "plant": {
     "id": "plant:eia:3845",
     "name": "Centralia Generating Facility"
    },
    "plant_code": "3845",
    "plant_name": "Transalta Centralia Generation",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Hydro",
    "claim_type": "Utility Specified",
    "fuel_type": "Water",
    "mwh": 1669662.0,
    "plant": {
     "id": "plant:eia:3883",
     "name": "Rocky Reach Dam"
    },
    "plant_code": "3883",
    "plant_name": "Rocky Reach",
    "rec": null,
    "renewable": true
   },
   {
    "category": "Natural Gas",
    "claim_type": "Utility Specified",
    "fuel_type": "Natural Gas",
    "mwh": 1560573.0,
    "plant": {
     "id": "plant:eia:55700",
     "name": "Mint Farm Generating Station"
    },
    "plant_code": "55700",
    "plant_name": "Mint Farm Generating Station",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Coal",
    "claim_type": "Utility Specified",
    "fuel_type": "Subbituminous Coal",
    "mwh": 1483438.0,
    "plant": {
     "id": "plant:eia:6076",
     "name": "Colstrip Steam Electric Station"
    },
    "plant_code": "6076",
    "plant_name": "Colstrip",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Natural Gas",
    "claim_type": "Utility Specified",
    "fuel_type": "Natural Gas",
    "mwh": 1447259.0,
    "plant": {
     "id": "plant:eia:55482",
     "name": "Goldendale Generating Station"
    },
    "plant_code": "55482",
    "plant_name": "Goldendale Generating Station",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Wind",
    "claim_type": "Utility Specified",
    "fuel_type": "Wind",
    "mwh": 1304376.0,
    "plant": {
     "id": "plant:eia:65577",
     "name": "Clearwater Wind I"
    },
    "plant_code": "65577",
    "plant_name": "Clearwater Wind I",
    "rec": "False",
    "renewable": true
   },
   {
    "category": "Natural Gas",
    "claim_type": "Utility Specified",
    "fuel_type": "Natural Gas",
    "mwh": 1145762.0,
    "plant": {
     "id": "plant:eia:54537",
     "name": "Ferndale Generating Station"
    },
    "plant_code": "54537",
    "plant_name": "Ferndale Generating Station",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Wind",
    "claim_type": "Utility Specified",
    "fuel_type": "Wind",
    "mwh": 922291.0,
    "plant": {
     "id": "plant:eia:57195",
     "name": "Lower Snake River Wind Energy Project"
    },
    "plant_code": "57195",
    "plant_name": "Lower Snake River Wind Energy Project",
    "rec": "True",
    "renewable": true
   },
   {
    "category": "Hydro",
    "claim_type": "Utility Specified",
    "fuel_type": "Water",
    "mwh": 911906.0,
    "plant": {
     "id": "plant:eia:6200",
     "name": "Rock Island Dam"
    },
    "plant_code": "6200",
    "plant_name": "Rock Island",
    "rec": null,
    "renewable": true
   },
   {
    "category": "Hydro",
    "claim_type": "Utility Specified",
    "fuel_type": "Water",
    "mwh": 786634.0,
    "plant": null,
    "plant_code": "900242",
    "plant_name": "GM Shrum",
    "rec": null,
    "renewable": true
   },
   {
    "category": "Wind",
    "claim_type": "Utility Specified",
    "fuel_type": "Wind",
    "mwh": 752186.0,
    "plant": {
     "id": "plant:eia:57195",
     "name": "Lower Snake River Wind Energy Project"
    },
    "plant_code": "57195",
    "plant_name": "Lower Snake River Wind Energy Project",
    "rec": "True",
    "renewable": true
   },
   {
    "category": "Natural Gas",
    "claim_type": "Utility Specified",
    "fuel_type": "Natural Gas",
    "mwh": 579357.0,
    "plant": {
     "id": "plant:eia:55818",
     "name": "Frederickson 1 Generating Station"
    },
    "plant_code": "55818",
    "plant_name": "Frederickson Power LP",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Hydro",
    "claim_type": "Utility Specified",
    "fuel_type": "Water",
    "mwh": 535550.0,
    "plant": {
     "id": "plant:eia:3886",
     "name": "Wells Dam"
    },
    "plant_code": "3886",
    "plant_name": "Wells",
    "rec": null,
    "renewable": true
   },
   {
    "category": "Natural Gas",
    "claim_type": "Utility Specified",
    "fuel_type": "Natural Gas",
    "mwh": 515711.0,
    "plant": {
     "id": "plant:eia:7870",
     "name": "Encogen"
    },
    "plant_code": "7870",
    "plant_name": "Encogen",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Natural Gas",
    "claim_type": "Utility Specified",
    "fuel_type": "Natural Gas",
    "mwh": 457277.0,
    "plant": {
     "id": "plant:eia:54476",
     "name": "Sumas Power Plant"
    },
    "plant_code": "54476",
    "plant_name": "Sumas Power Plant",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Hydro",
    "claim_type": "BPA Claim",
    "fuel_type": "Water",
    "mwh": 403980.0,
    "plant": null,
    "plant_code": "9999991",
    "plant_name": "BPA Claim",
    "rec": null,
    "renewable": true
   },
   {
    "category": "Natural Gas",
    "claim_type": "Utility Specified",
    "fuel_type": "Natural Gas",
    "mwh": 371479.0,
    "plant": {
     "id": "plant:eia:607",
     "name": "Fredonia"
    },
    "plant_code": "607",
    "plant_name": "Fredonia",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Hydro",
    "claim_type": "Utility Specified",
    "fuel_type": "Water",
    "mwh": 351266.0,
    "plant": {
     "id": "plant:eia:2188",
     "name": "Se̓liš Ksanka Ql̓ispe̓ Dam"
    },
    "plant_code": "2188",
    "plant_name": "Selis Ksanka Qlispe",
    "rec": null,
    "renewable": true
   },
   {
    "category": "Wind",
    "claim_type": "Utility Specified",
    "fuel_type": "Wind",
    "mwh": 350739.0,
    "plant": {
     "id": "plant:eia:56255",
     "name": "Hopkins Ridge Wind"
    },
    "plant_code": "56255",
    "plant_name": "Hopkins Ridge Wind",
    "rec": "True",
    "renewable": true
   },
   {
    "category": "Wind",
    "claim_type": "Utility Specified",
    "fuel_type": "Wind",
    "mwh": 348218.0,
    "plant": {
     "id": "plant:eia:63710",
     "name": "Golden Hill Wind"
    },
    "plant_code": "63710",
    "plant_name": "Golden Hill Wind",
    "rec": "True",
    "renewable": true
   },
   {
    "category": "Natural Gas",
    "claim_type": "Utility Specified",
    "fuel_type": "Natural Gas",
    "mwh": 344481.0,
    "plant": {
     "id": "plant:eia:54268",
     "name": "HF Sinclair Puget Sound Refining"
    },
    "plant_code": "54268",
    "plant_name": "HF Sinclair Puget Sound Refining",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Hydro",
    "claim_type": "Utility Specified",
    "fuel_type": "Water",
    "mwh": 317739.0,
    "plant": {
     "id": "plant:eia:3861",
     "name": "Upper Baker"
    },
    "plant_code": "3861",
    "plant_name": "Upper Baker",
    "rec": null,
    "renewable": true
   },
   {
    "category": "Wind",
    "claim_type": "Utility Specified",
    "fuel_type": "Wind",
    "mwh": 272993.0,
    "plant": {
     "id": "plant:eia:63710",
     "name": "Golden Hill Wind"
    },
    "plant_code": "63710",
    "plant_name": "Golden Hill Wind",
    "rec": null,
    "renewable": true
   },
   {
    "category": "Hydro",
    "claim_type": "Utility Specified",
    "fuel_type": "Water",
    "mwh": 222760.0,
    "plant": null,
    "plant_code": "900244",
    "plant_name": "MIC",
    "rec": null,
    "renewable": true
   },
   {
    "category": "Hydro",
    "claim_type": "Utility Specified",
    "fuel_type": "Water",
    "mwh": 183586.0,
    "plant": {
     "id": "plant:eia:3887",
     "name": "Priest Rapids Dam"
    },
    "plant_code": "3887",
    "plant_name": "Priest Rapids",
    "rec": null,
    "renewable": true
   },
   {
    "category": "Hydro",
    "claim_type": "Utility Specified",
    "fuel_type": "Water",
    "mwh": 152483.0,
    "plant": {
     "id": "plant:eia:3888",
     "name": "Wanapum Dam"
    },
    "plant_code": "3888",
    "plant_name": "Wanapum",
    "rec": null,
    "renewable": true
   },
   {
    "category": "Natural Gas",
    "claim_type": "Utility Specified",
    "fuel_type": "Natural Gas",
    "mwh": 151935.0,
    "plant": {
     "id": "plant:eia:6120",
     "name": "Whitehorn"
    },
    "plant_code": "6120",
    "plant_name": "Whitehorn",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Other Non-Biogenic",
    "claim_type": "Utility Specified",
    "fuel_type": "Other Gas",
    "mwh": 99920.0,
    "plant": {
     "id": "plant:eia:54268",
     "name": "HF Sinclair Puget Sound Refining"
    },
    "plant_code": "54268",
    "plant_name": "HF Sinclair Puget Sound Refining",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Wind",
    "claim_type": "Utility Specified",
    "fuel_type": "Wind",
    "mwh": 91340.0,
    "plant": {
     "id": "plant:eia:56322",
     "name": "Wild Horse"
    },
    "plant_code": "56322",
    "plant_name": "Wild Horse",
    "rec": "True",
    "renewable": true
   },
   {
    "category": "Hydro",
    "claim_type": "Utility Specified",
    "fuel_type": "Water",
    "mwh": 89806.0,
    "plant": {
     "id": "plant:eia:3855",
     "name": "Lower Baker"
    },
    "plant_code": "3855",
    "plant_name": "Lower Baker",
    "rec": "True",
    "renewable": true
   },
   {
    "category": "Biomass",
    "claim_type": "Utility Specified",
    "fuel_type": "Wood/Wood Waste Solids",
    "mwh": 82835.0,
    "plant": {
     "id": "plant:eia:56406",
     "name": "Sierra Pacific Burlington Facility"
    },
    "plant_code": "56406",
    "plant_name": "Sierra Pacific Burlington Facility",
    "rec": "True",
    "renewable": true
   },
   {
    "category": "Hydro",
    "claim_type": "Utility Specified",
    "fuel_type": "Water",
    "mwh": 79446.0,
    "plant": null,
    "plant_code": "900247",
    "plant_name": "Seven Mile",
    "rec": null,
    "renewable": true
   },
   {
    "category": "Nuclear",
    "claim_type": "BPA Claim",
    "fuel_type": "Nuclear",
    "mwh": 69208.0,
    "plant": null,
    "plant_code": "9999991",
    "plant_name": "BPA Claim",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Market",
    "claim_type": "BPA Claim",
    "fuel_type": "Market",
    "mwh": 63306.0,
    "plant": null,
    "plant_code": "9999991",
    "plant_name": "BPA Claim",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Hydro",
    "claim_type": "Utility Specified",
    "fuel_type": "Water",
    "mwh": 59441.0,
    "plant": null,
    "plant_code": "900246",
    "plant_name": "Revelstoke",
    "rec": null,
    "renewable": true
   },
   {
    "category": "Natural Gas",
    "claim_type": "Utility Specified",
    "fuel_type": "Natural Gas",
    "mwh": 46660.0,
    "plant": {
     "id": "plant:eia:99",
     "name": "Frederickson"
    },
    "plant_code": "99",
    "plant_name": "Frederickson",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Wind",
    "claim_type": "Utility Specified",
    "fuel_type": "Wind",
    "mwh": 43977.0,
    "plant": {
     "id": "plant:eia:56468",
     "name": "Klondike Windpower III"
    },
    "plant_code": "56468",
    "plant_name": "Klondike Windpower III",
    "rec": "True",
    "renewable": true
   },
   {
    "category": "Hydro",
    "claim_type": "Utility Specified",
    "fuel_type": "Water",
    "mwh": 28673.0,
    "plant": null,
    "plant_code": "900243",
    "plant_name": "Kootenay",
    "rec": null,
    "renewable": true
   },
   {
    "category": "Hydro",
    "claim_type": "Utility Specified",
    "fuel_type": "Water",
    "mwh": 19484.0,
    "plant": null,
    "plant_code": "900245",
    "plant_name": "Peace Canyon",
    "rec": null,
    "renewable": true
   },
   {
    "category": "Biomass",
    "claim_type": "Utility Specified",
    "fuel_type": "Wood/Wood Waste Solids",
    "mwh": 18600.0,
    "plant": null,
    "plant_code": "900238",
    "plant_name": "Cosmo Specialty Fibers Inc.",
    "rec": "True",
    "renewable": true
   },
   {
    "category": "Hydro",
    "claim_type": "Utility Specified",
    "fuel_type": "Water",
    "mwh": 16657.0,
    "plant": null,
    "plant_code": "900241",
    "plant_name": "Bridge River",
    "rec": null,
    "renewable": true
   },
   {
    "category": "Wind",
    "claim_type": "Utility Specified",
    "fuel_type": "Wind",
    "mwh": 13642.0,
    "plant": {
     "id": "plant:eia:56322",
     "name": "Wild Horse"
    },
    "plant_code": "56322",
    "plant_name": "Wild Horse",
    "rec": "True",
    "renewable": true
   },
   {
    "category": "Petroleum",
    "claim_type": "Utility Specified",
    "fuel_type": "Distillate Fuel Oil",
    "mwh": 12766.0,
    "plant": {
     "id": "plant:eia:99",
     "name": "Frederickson"
    },
    "plant_code": "99",
    "plant_name": "Frederickson",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Hydro",
    "claim_type": "Utility Specified",
    "fuel_type": "Water",
    "mwh": 10987.0,
    "plant": {
     "id": "plant:eia:7867",
     "name": "Snoqualmie 2"
    },
    "plant_code": "7867",
    "plant_name": "Snoqualmie 2",
    "rec": "True",
    "renewable": true
   },
   {
    "category": "Petroleum",
    "claim_type": "Utility Specified",
    "fuel_type": "Distillate Fuel Oil",
    "mwh": 5719.0,
    "plant": {
     "id": "plant:eia:3845",
     "name": "Centralia Generating Facility"
    },
    "plant_code": "3845",
    "plant_name": "Transalta Centralia Generation",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Petroleum",
    "claim_type": "Utility Specified",
    "fuel_type": "Distillate Fuel Oil",
    "mwh": 3866.0,
    "plant": {
     "id": "plant:eia:6120",
     "name": "Whitehorn"
    },
    "plant_code": "6120",
    "plant_name": "Whitehorn",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Hydro",
    "claim_type": "Utility Specified",
    "fuel_type": "Water",
    "mwh": 3719.0,
    "plant": {
     "id": "plant:eia:3860",
     "name": "Snoqualmie"
    },
    "plant_code": "3860",
    "plant_name": "Snoqualmie",
    "rec": "True",
    "renewable": true
   },
   {
    "category": "Petroleum",
    "claim_type": "Utility Specified",
    "fuel_type": "Distillate Fuel Oil",
    "mwh": 3563.0,
    "plant": {
     "id": "plant:eia:607",
     "name": "Fredonia"
    },
    "plant_code": "607",
    "plant_name": "Fredonia",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Hydro",
    "claim_type": "Utility Specified",
    "fuel_type": "Water",
    "mwh": 2905.0,
    "plant": null,
    "plant_code": "900018",
    "plant_name": "Cheakamus Generating Station",
    "rec": null,
    "renewable": true
   },
   {
    "category": "Petroleum",
    "claim_type": "Utility Specified",
    "fuel_type": "Distillate Fuel Oil",
    "mwh": 1855.0,
    "plant": {
     "id": "plant:eia:6076",
     "name": "Colstrip Steam Electric Station"
    },
    "plant_code": "6076",
    "plant_name": "Colstrip",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Petroleum",
    "claim_type": "Utility Specified",
    "fuel_type": "Distillate Fuel Oil",
    "mwh": 1608.0,
    "plant": {
     "id": "plant:eia:54537",
     "name": "Ferndale Generating Station"
    },
    "plant_code": "54537",
    "plant_name": "Ferndale Generating Station",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Petroleum",
    "claim_type": "Utility Specified",
    "fuel_type": "Distillate Fuel Oil",
    "mwh": 1192.0,
    "plant": {
     "id": "plant:eia:7870",
     "name": "Encogen"
    },
    "plant_code": "7870",
    "plant_name": "Encogen",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Hydro",
    "claim_type": "Utility Specified",
    "fuel_type": "Water",
    "mwh": 764.0,
    "plant": {
     "id": "plant:eia:6424",
     "name": "Chelan"
    },
    "plant_code": "6424",
    "plant_name": "Chelan",
    "rec": null,
    "renewable": true
   },
   {
    "category": "Petroleum",
    "claim_type": "Utility Specified",
    "fuel_type": "Distillate Fuel Oil",
    "mwh": 248.0,
    "plant": {
     "id": "plant:eia:3853",
     "name": "Crystal Mountain"
    },
    "plant_code": "3853",
    "plant_name": "Crystal Mountain",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Solar",
    "claim_type": "Utility Specified",
    "fuel_type": "Solar",
    "mwh": 168.0,
    "plant": null,
    "plant_code": "900045",
    "plant_name": "Distributed Generation--Solar (WA)",
    "rec": null,
    "renewable": true
   },
   {
    "category": "Solar",
    "claim_type": "Utility Specified",
    "fuel_type": "Solar",
    "mwh": 96.0,
    "plant": {
     "id": "plant:eia:56322",
     "name": "Wild Horse"
    },
    "plant_code": "56322",
    "plant_name": "Wild Horse",
    "rec": "True",
    "renewable": true
   },
   {
    "category": "Solar",
    "claim_type": "Utility Specified",
    "fuel_type": "Solar",
    "mwh": 14.0,
    "plant": {
     "id": "plant:eia:56322",
     "name": "Wild Horse"
    },
    "plant_code": "56322",
    "plant_name": "Wild Horse",
    "rec": "True",
    "renewable": true
   },
   {
    "category": "Coal",
    "claim_type": "Utility Specified",
    "fuel_type": "Refined Coal",
    "mwh": 0.0,
    "plant": {
     "id": "plant:eia:3845",
     "name": "Centralia Generating Facility"
    },
    "plant_code": "3845",
    "plant_name": "Transalta Centralia Generation",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Coal",
    "claim_type": "Utility Specified",
    "fuel_type": "Waste/Other Coal",
    "mwh": 0.0,
    "plant": {
     "id": "plant:eia:3845",
     "name": "Centralia Generating Facility"
    },
    "plant_code": "3845",
    "plant_name": "Transalta Centralia Generation",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Petroleum",
    "claim_type": "Utility Specified",
    "fuel_type": "Jet Fuel",
    "mwh": 0.0,
    "plant": {
     "id": "plant:eia:54268",
     "name": "HF Sinclair Puget Sound Refining"
    },
    "plant_code": "54268",
    "plant_name": "HF Sinclair Puget Sound Refining",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Petroleum",
    "claim_type": "Utility Specified",
    "fuel_type": "Distillate Fuel Oil",
    "mwh": 0.0,
    "plant": {
     "id": "plant:eia:54268",
     "name": "HF Sinclair Puget Sound Refining"
    },
    "plant_code": "54268",
    "plant_name": "HF Sinclair Puget Sound Refining",
    "rec": null,
    "renewable": false
   },
   {
    "category": "Petroleum",
    "claim_type": "Utility Specified",
    "fuel_type": "Waste/Other Oil",
    "mwh": 0.0,
    "plant": {
     "id": "plant:eia:6076",
     "name": "Colstrip Steam Electric Station"
    },
    "plant_code": "6076",
    "plant_name": "Colstrip",
    "rec": null,
    "renewable": false
   }
  ],
  "plant_claims_total": 62,
  "products": [
   {
    "claimant_id": 167,
    "claimant_name": "Puget Sound Energy Green Direct Program"
   }
  ],
  "report_year": 2024,
  "source_ref": "wa-fmd-2024-by-category",
  "state": "WA",
  "unspecified_share": 0.0031
 },
 "distributed": {
  "by_class": [
   {
    "capacity_mw": 175.041,
    "coverage": {
     "capacity_mw": {
      "eligible": 13,
      "included": 3,
      "unit": "native rows"
     },
     "customers": {
      "eligible": 13,
      "included": 3,
      "unit": "native rows"
     }
    },
    "customer_class": "residential",
    "customers": 23805,
    "is_storage": false,
    "quality": "suspect",
    "rows": 13,
    "utilities": 1
   },
   {
    "capacity_mw": 37.888,
    "coverage": {
     "capacity_mw": {
      "eligible": 13,
      "included": 7,
      "unit": "native rows"
     },
     "customers": {
      "eligible": 13,
      "included": 3,
      "unit": "native rows"
     }
    },
    "customer_class": "commercial",
    "customers": 1398,
    "is_storage": false,
    "quality": "suspect",
    "rows": 13,
    "utilities": 1
   },
   {
    "capacity_mw": 0.445,
    "coverage": {
     "capacity_mw": {
      "eligible": 13,
      "included": 2,
      "unit": "native rows"
     },
     "customers": {
      "eligible": 13,
      "included": 2,
      "unit": "native rows"
     }
    },
    "customer_class": "industrial",
    "customers": 10,
    "is_storage": false,
    "quality": "suspect",
    "rows": 13,
    "utilities": 1
   },
   {
    "capacity_mw": null,
    "coverage": {
     "capacity_mw": {
      "eligible": 13,
      "included": 0,
      "unit": "native rows"
     },
     "customers": {
      "eligible": 13,
      "included": 0,
      "unit": "native rows"
     }
    },
    "customer_class": "transportation",
    "customers": null,
    "is_storage": false,
    "quality": "missing",
    "rows": 13,
    "utilities": 1
   },
   {
    "capacity_mw": null,
    "coverage": {
     "capacity_mw": {
      "eligible": 8,
      "included": 0,
      "unit": "native rows"
     },
     "customers": {
      "eligible": 8,
      "included": 0,
      "unit": "native rows"
     }
    },
    "customer_class": "direct_connection",
    "customers": null,
    "is_storage": false,
    "quality": "missing",
    "rows": 8,
    "utilities": 1
   }
  ],
  "by_tech": [
   {
    "capacity_mw": 203.16,
    "coverage": {
     "capacity_mw": {
      "eligible": 4,
      "included": 3,
      "unit": "native rows"
     },
     "customers": {
      "eligible": 4,
      "included": 3,
      "unit": "native rows"
     }
    },
    "customers": 25163,
    "is_storage": false,
    "program": "net_metering",
    "quality": "suspect",
    "rows": 4,
    "tech_class": "pv",
    "utilities": 1
   },
   {
    "capacity_mw": 13.68,
    "coverage": {
     "capacity_mw": {
      "eligible": 4,
      "included": 2,
      "unit": "native rows"
     },
     "customers": {
      "eligible": 4,
      "included": 2,
      "unit": "native rows"
     }
    },
    "customers": 1777,
    "is_storage": true,
    "program": "net_metering",
    "quality": "suspect",
    "rows": 4,
    "tech_class": "storage_pv",
    "utilities": 1
   },
   {
    "capacity_mw": 6.116,
    "coverage": {
     "capacity_mw": {
      "eligible": 5,
      "included": 1,
      "unit": "native rows"
     },
     "customers": {
      "eligible": 5,
      "included": 0,
      "unit": "native rows"
     }
    },
    "customers": null,
    "is_storage": false,
    "program": "non_net_metering",
    "quality": "suspect",
    "rows": 5,
    "tech_class": "pv",
    "utilities": 1
   },
   {
    "capacity_mw": 2.875,
    "coverage": {
     "capacity_mw": {
      "eligible": 5,
      "included": 1,
      "unit": "native rows"
     },
     "customers": {
      "eligible": 5,
      "included": 0,
      "unit": "native rows"
     }
    },
    "customers": null,
    "is_storage": false,
    "program": "non_net_metering",
    "quality": "suspect",
    "rows": 5,
    "tech_class": "internal_combustion",
    "utilities": 1
   },
   {
    "capacity_mw": 0.568,
    "coverage": {
     "capacity_mw": {
      "eligible": 5,
      "included": 1,
      "unit": "native rows"
     },
     "customers": {
      "eligible": 5,
      "included": 0,
      "unit": "native rows"
     }
    },
    "customers": null,
    "is_storage": false,
    "program": "non_net_metering",
    "quality": "suspect",
    "rows": 5,
    "tech_class": "hydro",
    "utilities": 1
   },
   {
    "capacity_mw": 0.353,
    "coverage": {
     "capacity_mw": {
      "eligible": 4,
      "included": 3,
      "unit": "native rows"
     },
     "customers": {
      "eligible": 4,
      "included": 3,
      "unit": "native rows"
     }
    },
    "customers": 23,
    "is_storage": false,
    "program": "net_metering",
    "quality": "suspect",
    "rows": 4,
    "tech_class": "other",
    "utilities": 1
   },
   {
    "capacity_mw": 0.228,
    "coverage": {
     "capacity_mw": {
      "eligible": 5,
      "included": 1,
      "unit": "native rows"
     },
     "customers": {
      "eligible": 5,
      "included": 0,
      "unit": "native rows"
     }
    },
    "customers": null,
    "is_storage": false,
    "program": "non_net_metering",
    "quality": "suspect",
    "rows": 5,
    "tech_class": "wind",
    "utilities": 1
   },
   {
    "capacity_mw": 0.074,
    "coverage": {
     "capacity_mw": {
      "eligible": 4,
      "included": 2,
      "unit": "native rows"
     },
     "customers": {
      "eligible": 4,
      "included": 2,
      "unit": "native rows"
     }
    },
    "customers": 27,
    "is_storage": false,
    "program": "net_metering",
    "quality": "suspect",
    "rows": 4,
    "tech_class": "wind",
    "utilities": 1
   },
   {
    "capacity_mw": null,
    "coverage": {
     "capacity_mw": {
      "eligible": 4,
      "included": 0,
      "unit": "native rows"
     },
     "customers": {
      "eligible": 4,
      "included": 0,
      "unit": "native rows"
     }
    },
    "customers": null,
    "is_storage": false,
    "program": "net_metering",
    "quality": "missing",
    "rows": 4,
    "tech_class": "chp_cogen",
    "utilities": 1
   },
   {
    "capacity_mw": null,
    "coverage": {
     "capacity_mw": {
      "eligible": 4,
      "included": 0,
      "unit": "native rows"
     },
     "customers": {
      "eligible": 4,
      "included": 0,
      "unit": "native rows"
     }
    },
    "customers": null,
    "is_storage": true,
    "program": "net_metering",
    "quality": "missing",
    "rows": 4,
    "tech_class": "storage_nonpv",
    "utilities": 1
   },
   {
    "capacity_mw": null,
    "coverage": {
     "capacity_mw": {
      "eligible": 4,
      "included": 0,
      "unit": "native rows"
     },
     "customers": {
      "eligible": 4,
      "included": 0,
      "unit": "native rows"
     }
    },
    "customers": null,
    "is_storage": false,
    "program": "net_metering",
    "quality": "missing",
    "rows": 4,
    "tech_class": "virtual_pv",
    "utilities": 1
   },
   {
    "capacity_mw": null,
    "coverage": {
     "capacity_mw": {
      "eligible": 5,
      "included": 0,
      "unit": "native rows"
     },
     "customers": {
      "eligible": 5,
      "included": 0,
      "unit": "native rows"
     }
    },
    "customers": null,
    "is_storage": false,
    "program": "non_net_metering",
    "quality": "missing",
    "rows": 5,
    "tech_class": "combustion_turbine",
    "utilities": 1
   },
   {
    "capacity_mw": null,
    "coverage": {
     "capacity_mw": {
      "eligible": 5,
      "included": 0,
      "unit": "native rows"
     },
     "customers": {
      "eligible": 5,
      "included": 0,
      "unit": "native rows"
     }
    },
    "customers": null,
    "is_storage": false,
    "program": "non_net_metering",
    "quality": "missing",
    "rows": 5,
    "tech_class": "fuel_cell",
    "utilities": 1
   },
   {
    "capacity_mw": null,
    "coverage": {
     "capacity_mw": {
      "eligible": 5,
      "included": 0,
      "unit": "native rows"
     },
     "customers": {
      "eligible": 5,
      "included": 0,
      "unit": "native rows"
     }
    },
    "customers": null,
    "is_storage": false,
    "program": "non_net_metering",
    "quality": "missing",
    "rows": 5,
    "tech_class": "other",
    "utilities": 1
   },
   {
    "capacity_mw": null,
    "coverage": {
     "capacity_mw": {
      "eligible": 5,
      "included": 0,
      "unit": "native rows"
     },
     "customers": {
      "eligible": 5,
      "included": 0,
      "unit": "native rows"
     }
    },
    "customers": null,
    "is_storage": false,
    "program": "non_net_metering",
    "quality": "missing",
    "rows": 5,
    "tech_class": "steam",
    "utilities": 1
   }
  ],
  "coverage": {
   "leaf_rows": 68,
   "net_metering_source_total_row_mw": 203.587,
   "rollup_rows_excluded": 24,
   "utilities": 1
  },
  "facts": [
   {
    "basis": "Sum of EIA-861 utility-reported nameplate capacity over leaf technology classes, excluding storage and source rollup rows; utility x state grain; no locations; not part of the EIA-860 plant inventory",
    "coverage": {
     "blank_cells_excluded": 48,
     "eligible": 1,
     "included": 1,
     "unit": "reporting utilities"
    },
    "denominator": null,
    "evidence": "reported",
    "fact_id": "org:eia:15500/distributed#distributed_capacity_mw@2024",
    "label": "Distributed generation capacity (net-metered + non-net-metered)",
    "locator": "core_eia861__yearly_net_metering_customer_fuel_class.parquet; report_date=2024-01-01; utility_id_eia=15500 (+ non-net-metering table)",
    "maturity": "final",
    "method": "derived",
    "metric": "distributed_capacity_mw",
    "missing_reason": null,
    "note": "net-metered + non-net-metered; the two EIA-861 schedules are disjoint by design",
    "period": {
     "hours": 8784,
     "kind": "calendar_year",
     "period_end": "2025-01-01T00:00:00Z",
     "period_start": "2024-01-01T00:00:00Z",
     "year": 2024
    },
    "precision": 1,
    "quality": "valid",
    "source_ref": "pudl-net-metering",
    "unit": "MW",
    "value": 213.374
   },
   {
    "basis": "EIA-861 net metering schedule, leaf technology classes excluding storage",
    "coverage": {
     "blank_cells_excluded": 12,
     "eligible": 1,
     "included": 1,
     "unit": "reporting utilities"
    },
    "denominator": null,
    "evidence": "reported",
    "fact_id": "org:eia:15500/distributed#net_metering_capacity_mw@2024",
    "label": "Net-metered capacity",
    "locator": "core_eia861__yearly_net_metering_customer_fuel_class.parquet; report_date=2024-01-01; utility_id_eia=15500 (+ non-net-metering table)",
    "maturity": "final",
    "method": "derived",
    "metric": "net_metering_capacity_mw",
    "missing_reason": null,
    "note": null,
    "period": {
     "hours": 8784,
     "kind": "calendar_year",
     "period_end": "2025-01-01T00:00:00Z",
     "period_start": "2024-01-01T00:00:00Z",
     "year": 2024
    },
    "precision": 1,
    "quality": "valid",
    "source_ref": "pudl-net-metering",
    "unit": "MW",
    "value": 203.587
   },
   {
    "basis": "EIA-861 non-net-metering distributed generation schedule, leaf technology classes excluding storage",
    "coverage": {
     "blank_cells_excluded": 36,
     "eligible": 1,
     "included": 1,
     "unit": "reporting utilities"
    },
    "denominator": null,
    "evidence": "reported",
    "fact_id": "org:eia:15500/distributed#non_net_metering_capacity_mw@2024",
    "label": "Non-net-metered distributed capacity",
    "locator": "core_eia861__yearly_net_metering_customer_fuel_class.parquet; report_date=2024-01-01; utility_id_eia=15500 (+ non-net-metering table)",
    "maturity": "final",
    "method": "derived",
    "metric": "non_net_metering_capacity_mw",
    "missing_reason": null,
    "note": null,
    "period": {
     "hours": 8784,
     "kind": "calendar_year",
     "period_end": "2025-01-01T00:00:00Z",
     "period_start": "2024-01-01T00:00:00Z",
     "year": 2024
    },
    "precision": 1,
    "quality": "valid",
    "source_ref": "pudl-non-net-metering",
    "unit": "MW",
    "value": 9.786999999999999
   },
   {
    "basis": "EIA-861 net metering customer count over leaf technology classes; a customer with two technologies can be counted twice by the source",
    "coverage": {
     "blank_cells_excluded": 12,
     "eligible": 1,
     "included": 1,
     "unit": "reporting utilities"
    },
    "denominator": null,
    "evidence": "reported",
    "fact_id": "org:eia:15500/distributed#net_metering_customers@2024",
    "label": "Net-metered customers",
    "locator": "core_eia861__yearly_net_metering_customer_fuel_class.parquet; report_date=2024-01-01; utility_id_eia=15500 (+ non-net-metering table)",
    "maturity": "final",
    "method": "derived",
    "metric": "net_metering_customers",
    "missing_reason": null,
    "note": null,
    "period": {
     "hours": 8784,
     "kind": "calendar_year",
     "period_end": "2025-01-01T00:00:00Z",
     "period_start": "2024-01-01T00:00:00Z",
     "year": 2024
    },
    "precision": 0,
    "quality": "valid",
    "source_ref": "pudl-net-metering",
    "unit": "count",
    "value": 25213.0
   },
   {
    "basis": "EIA-861 net metering schedule; export to the utility, not customer generation",
    "coverage": {
     "blank_cells_excluded": 20,
     "eligible": 1,
     "included": 0,
     "unit": "reporting utilities"
    },
    "denominator": null,
    "evidence": "reported",
    "fact_id": "org:eia:15500/distributed#net_metering_sold_to_utility_mwh@2024",
    "label": "Energy sold back to the utility by net-metered customers",
    "locator": "core_eia861__yearly_net_metering_customer_fuel_class.parquet; report_date=2024-01-01; utility_id_eia=15500 (+ non-net-metering table)",
    "maturity": "final",
    "method": "derived",
    "metric": "net_metering_sold_to_utility_mwh",
    "missing_reason": "not_reported",
    "note": "1 of 1 reporting utilities have no value for this metric",
    "period": {
     "hours": 8784,
     "kind": "calendar_year",
     "period_end": "2025-01-01T00:00:00Z",
     "period_start": "2024-01-01T00:00:00Z",
     "year": 2024
    },
    "precision": 0,
    "quality": "missing",
    "source_ref": "pudl-net-metering",
    "unit": "MWh",
    "value": null
   },
   {
    "basis": "EIA-861 storage technology classes (storage_pv, storage_nonpv, all_storage); power rating, kept separate from generation capacity",
    "coverage": {
     "blank_cells_excluded": 6,
     "eligible": 1,
     "included": 1,
     "unit": "reporting utilities"
    },
    "denominator": null,
    "evidence": "reported",
    "fact_id": "org:eia:15500/distributed#distributed_storage_capacity_mw@2024",
    "label": "Distributed storage capacity",
    "locator": "core_eia861__yearly_net_metering_customer_fuel_class.parquet; report_date=2024-01-01; utility_id_eia=15500 (+ non-net-metering table)",
    "maturity": "final",
    "method": "derived",
    "metric": "distributed_storage_capacity_mw",
    "missing_reason": null,
    "note": null,
    "period": {
     "hours": 8784,
     "kind": "calendar_year",
     "period_end": "2025-01-01T00:00:00Z",
     "period_start": "2024-01-01T00:00:00Z",
     "year": 2024
    },
    "precision": 1,
    "quality": "valid",
    "source_ref": "pudl-net-metering",
    "unit": "MW",
    "value": 13.68
   },
   {
    "basis": "EIA-861 storage technology classes; usable energy as reported",
    "coverage": {
     "blank_cells_excluded": 6,
     "eligible": 1,
     "included": 1,
     "unit": "reporting utilities"
    },
    "denominator": null,
    "evidence": "reported",
    "fact_id": "org:eia:15500/distributed#distributed_storage_energy_mwh@2024",
    "label": "Distributed storage energy capacity",
    "locator": "core_eia861__yearly_net_metering_customer_fuel_class.parquet; report_date=2024-01-01; utility_id_eia=15500 (+ non-net-metering table)",
    "maturity": "final",
    "method": "derived",
    "metric": "distributed_storage_energy_mwh",
    "missing_reason": null,
    "note": null,
    "period": {
     "hours": 8784,
     "kind": "calendar_year",
     "period_end": "2025-01-01T00:00:00Z",
     "period_start": "2024-01-01T00:00:00Z",
     "year": 2024
    },
    "precision": 1,
    "quality": "valid",
    "source_ref": "pudl-net-metering",
    "unit": "MWh",
    "value": 25.933
   }
  ],
  "note": "Utility-reported, no locations, not in the EIA-860 plant inventory (>= 1 MW). Storage is listed separately and never added to generation capacity. Non-net-metered units >= 1 MW can also appear in EIA-860; the overlap is disclosed, not resolved. Source rollup rows are excluded from every sum.",
  "scope_sentence": "Distributed generation reported by this utility to EIA-861 for 2024, by state"
 },
 "distribution_screening": null,
 "entity_type": "I",
 "entity_type_label": "Investor-owned utility",
 "facts": [
  {
   "basis": "Sum of operating generator nameplate MW at plants where this organization is the reported operator",
   "coverage": {
    "eligible": 19,
    "included": 19,
    "plants_with_partial_capacity": 0,
    "unit": "plants"
   },
   "denominator": null,
   "evidence": "reported",
   "fact_id": "org:eia:15500#operated_nameplate_mw_op@2024",
   "label": "Operated nameplate capacity, operating generators",
   "locator": "out_eia__yearly_utilities.parquet; report_date=2024-01-01; utility_id_eia=15500",
   "maturity": "final",
   "method": "derived",
   "metric": "operated_nameplate_mw_op",
   "missing_reason": null,
   "note": "Reported operating capacity; partial plant/unit coverage is marked",
   "period": {
    "kind": "inventory_year",
    "note": "EIA-860 annual inventory; status as of the end of the reporting year",
    "report_date": "2024-01-01",
    "year": 2024
   },
   "precision": 1,
   "quality": "valid",
   "source_ref": "pudl-generators",
   "unit": "MW",
   "value": 2590.8
  },
  {
   "basis": "Sum over operating generators of nameplate MW x this organization's ownership fraction (reported schedule or EIA-860 schedule-4 default)",
   "coverage": {
    "eligible": 17,
    "included": 17,
    "unit": "plants"
   },
   "denominator": null,
   "evidence": "reported",
   "fact_id": "org:eia:15500#owned_nameplate_mw_op@2024",
   "label": "Owned nameplate capacity, operating generators",
   "locator": "out_eia__yearly_utilities.parquet; report_date=2024-01-01; utility_id_eia=15500",
   "maturity": "final",
   "method": "derived",
   "metric": "owned_nameplate_mw_op",
   "missing_reason": null,
   "note": null,
   "period": {
    "kind": "inventory_year",
    "note": "EIA-860 annual inventory; status as of the end of the reporting year",
    "report_date": "2024-01-01",
    "year": 2024
   },
   "precision": 1,
   "quality": "valid",
   "source_ref": "pudl-ownership",
   "unit": "MW",
   "value": 3161.32255
  }
 ],
 "id": "org:eia:15500",
 "money": {
  "available": true,
  "currency": "USD nominal",
  "expenses": {
   "note": "Schedule 320 electric operation and maintenance: function totals as the form computes them (as_computed) with the purchased power, fuel and wheeling accounts listed beneath as components, never added again",
   "rows": [
    {
     "as_computed": true,
     "component": false,
     "expense_type": "operations_and_maintenance_expenses_electric",
     "ferc_account": null,
     "label": "Total electric O&M",
     "usd": 2581537393.0
    },
    {
     "as_computed": true,
     "component": false,
     "expense_type": "power_production_expenses",
     "ferc_account": null,
     "label": "Power production",
     "usd": 1686866353.0
    },
    {
     "as_computed": false,
     "component": true,
     "expense_type": "purchased_power",
     "ferc_account": "555",
     "label": "of which purchased power (account 555)",
     "usd": 1208281072.0
    },
    {
     "as_computed": false,
     "component": true,
     "expense_type": "fuel_steam_power_generation",
     "ferc_account": "501",
     "label": "of which fuel, steam generation (501)",
     "usd": 56862104.0
    },
    {
     "as_computed": false,
     "component": true,
     "expense_type": "fuel",
     "ferc_account": "547",
     "label": "of which fuel, other generation (547)",
     "usd": 275829197.0
    },
    {
     "as_computed": true,
     "component": false,
     "expense_type": "transmission_expenses",
     "ferc_account": null,
     "label": "Transmission",
     "usd": 226702410.0
    },
    {
     "as_computed": true,
     "component": false,
     "expense_type": "distribution_expenses",
     "ferc_account": null,
     "label": "Distribution",
     "usd": 136858691.0
    },
    {
     "as_computed": true,
     "component": false,
     "expense_type": "customer_account_expenses",
     "ferc_account": null,
     "label": "Customer accounts",
     "usd": 68451478.0
    },
    {
     "as_computed": true,
     "component": false,
     "expense_type": "customer_service_and_information_expenses",
     "ferc_account": null,
     "label": "Customer service and information",
     "usd": 265798532.0
    },
    {
     "as_computed": true,
     "component": false,
     "expense_type": "sales_expenses",
     "ferc_account": null,
     "label": "Sales",
     "usd": 1188192.0
    },
    {
     "as_computed": true,
     "component": false,
     "expense_type": "administrative_and_general_operation_expense",
     "ferc_account": null,
     "label": "Administrative and general, operation",
     "usd": 176533111.0
    },
    {
     "as_computed": true,
     "component": false,
     "expense_type": "administrative_and_general_maintenance_expenses",
     "ferc_account": "935",
     "label": "Administrative and general, maintenance",
     "usd": 19138626.0
    },
    {
     "as_computed": false,
     "component": true,
     "expense_type": "transmission_of_electricity_by_others",
     "ferc_account": "565",
     "label": "of which transmission by others (565)",
     "usd": 196912868.0
    }
   ],
   "source_ref": "pudl-ferc1-operating-expenses"
  },
  "facts": [
   {
    "basis": "FERC Form 1 Schedule 326 total settlement over named sellers (adjustment rows excluded), nominal dollars for the report year",
    "coverage": {
     "eligible": 119,
     "included": 117,
     "unit": "native rows"
    },
    "denominator": null,
    "evidence": "reported",
    "fact_id": "org:eia:15500#purchased_power_usd@2025",
    "label": "Purchased power, settlements",
    "locator": "utility_id_ferc1=162; report_year=2025",
    "maturity": "final",
    "method": "derived",
    "metric": "purchased_power_usd",
    "missing_reason": null,
    "note": "95 named sellers; 3 adjustment and 2 market-settlement rows and the filing total row excluded",
    "period": {
     "hours": null,
     "kind": "calendar_year",
     "period_end": "2026-01-01T00:00:00Z",
     "period_start": "2025-01-01T00:00:00Z",
     "year": 2025
    },
    "precision": 0,
    "quality": "suspect",
    "source_ref": "pudl-ferc1-purchased-power",
    "unit": "USD",
    "value": 1165290255.0
   },
   {
    "basis": "FERC Form 1 Schedule 326 purchased MWh over named sellers (purchased_mwh through 2020, purchased other than storage from 2021)",
    "coverage": {
     "eligible": 119,
     "included": 119,
     "unit": "native rows"
    },
    "denominator": null,
    "evidence": "reported",
    "fact_id": "org:eia:15500#purchased_power_mwh@2025",
    "label": "Purchased power, energy",
    "locator": "utility_id_ferc1=162; report_year=2025",
    "maturity": "final",
    "method": "derived",
    "metric": "purchased_power_mwh",
    "missing_reason": null,
    "note": "Sum of reported MWh on named counterparty rows; missing cells are excluded and coverage is explicit",
    "period": {
     "hours": null,
     "kind": "calendar_year",
     "period_end": "2026-01-01T00:00:00Z",
     "period_start": "2025-01-01T00:00:00Z",
     "year": 2025
    },
    "precision": 0,
    "quality": "valid",
    "source_ref": "pudl-ferc1-purchased-power",
    "unit": "MWh",
    "value": 18492408.0
   },
   {
    "basis": "FERC Form 1 Schedule 300 sales to ultimate consumers plus sales for resale, nominal dollars",
    "coverage": null,
    "denominator": null,
    "evidence": "reported",
    "fact_id": "org:eia:15500#operating_revenue_usd@2025",
    "label": "Electric operating revenue",
    "locator": "utility_id_ferc1=162; report_year=2025",
    "maturity": "final",
    "method": "direct",
    "metric": "operating_revenue_usd",
    "missing_reason": null,
    "note": "The form's own electric operating revenues total (Schedule 300), as filed",
    "period": {
     "hours": null,
     "kind": "calendar_year",
     "period_end": "2026-01-01T00:00:00Z",
     "period_start": "2025-01-01T00:00:00Z",
     "year": 2025
    },
    "precision": 0,
    "quality": "valid",
    "source_ref": "pudl-ferc1-operating-revenues",
    "unit": "USD",
    "value": 3935546817.0
   }
  ],
  "ferc1": {
   "link_basis": "pudl_assn_1to1",
   "name": "Puget Sound Energy, Inc.",
   "related_eia_ids": null,
   "utility_id_ferc1": 162,
   "xbrl_entity_id": "C000171"
  },
  "note": "Nominal dollars for the report year as filed; revisions arrive for months after the April deadline; the pinned PUDL release fixes the snapshot",
  "purchased_power": {
   "adjustments": [
    {
     "edge": "adjustment",
     "mwh": 0.0,
     "name": "ca carbon obligation",
     "purchase_type": "AD",
     "usd": 419074.0
    },
    {
     "edge": "adjustment",
     "mwh": 0.0,
     "name": "residential exchange",
     "purchase_type": "AD",
     "usd": -82212871.0
    },
    {
     "edge": "adjustment",
     "mwh": 0.0,
     "name": "washington emission allowance",
     "purchase_type": "AD",
     "usd": 95458798.0
    }
   ],
   "market_settlements": [
    {
     "edge": "M6",
     "mwh": 1079794.0,
     "name": "california iso - eim purchases",
     "purchase_type": "OS",
     "usd": 26275860.0
    },
    {
     "edge": "M6",
     "mwh": 95861.0,
     "name": "california iso",
     "purchase_type": "OS",
     "usd": 3049956.0
    }
   ],
   "note": "Missing cells stay missing; partial seller sums are marked and have no USD/MWh ratio. FERC Form 1 Schedule 326 rows for the report year; seller names as filed; an organization link exists only through a reviewed crosswalk row; MWh uses purchased_mwh through 2020 and purchased other than storage from 2021. A row counts as a seller when it names a party, whatever its purchase type: FERC's AD code marks an adjusting entry, and an adjusting entry naming a company is still money between that company and the respondent. Rows whose name is a mechanism (deferrals, allowances, the residential exchange) are listed as adjustments; rows naming a market operator are listed as market settlements",
   "purchase_types": {
    "AD": "adjustment",
    "EX": "electricity_exchange",
    "IF": "intermediate_firm",
    "IU": "intermediate_unit",
    "LF": "long_firm",
    "LU": "long_unit",
    "OS": "other_service",
    "RQ": "requirement",
    "SF": "short_firm"
   },
   "sellers": [
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 3669981.0,
     "partial": false,
     "purchase_types": [
      "IU"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "grays harbor energy llc",
     "tariffs": [],
     "usd": 176652339.0,
     "usd_per_mwh": 48.13
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 1091992.0,
     "partial": false,
     "purchase_types": [
      "IF"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "powerex capacity",
     "tariffs": [],
     "usd": 170217002.0,
     "usd_per_mwh": 155.88
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 2625032.0,
     "partial": false,
     "purchase_types": [
      "AD",
      "LU"
     ],
     "rows": 2,
     "seller": {
      "id": "org:eia:19099",
      "name": "TransAlta Centralia Generation",
      "relation": "reviewed"
     },
     "seller_name": "transalta centralia generation llc",
     "tariffs": [],
     "usd": 159202388.0,
     "usd_per_mwh": 60.65
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 2846803.0,
     "partial": false,
     "purchase_types": [
      "AD",
      "LU"
     ],
     "rows": 2,
     "seller": {
      "id": "org:eia:3413",
      "name": "Chelan County PUD",
      "relation": "reviewed"
     },
     "seller_name": "chelan pud - rock island and rocky reach",
     "tariffs": [],
     "usd": 140663978.0,
     "usd_per_mwh": 49.41
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 720408.0,
     "partial": false,
     "purchase_types": [
      "IU",
      "OS"
     ],
     "rows": 2,
     "seller": {
      "id": "org:eia:3413",
      "name": "Chelan County PUD",
      "relation": "reviewed"
     },
     "seller_name": "chelan county pud #1",
     "tariffs": [],
     "usd": 68752517.0,
     "usd_per_mwh": 95.44
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 622034.0,
     "partial": false,
     "purchase_types": [
      "AD",
      "LU"
     ],
     "rows": 2,
     "seller": {
      "id": "org:eia:5326",
      "name": "Douglas County PUD",
      "relation": "reviewed"
     },
     "seller_name": "douglas pud - wells project",
     "tariffs": [],
     "usd": 41097849.0,
     "usd_per_mwh": 66.07
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 1328833.0,
     "partial": false,
     "purchase_types": [
      "AD",
      "LU"
     ],
     "rows": 2,
     "seller": null,
     "seller_name": "clearwater wind",
     "tariffs": [],
     "usd": 35253698.0,
     "usd_per_mwh": 26.53
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 606159.0,
     "partial": false,
     "purchase_types": [
      "AD",
      "IU"
     ],
     "rows": 2,
     "seller": null,
     "seller_name": "hf sinclair (mar pt)",
     "tariffs": [],
     "usd": 33606933.0,
     "usd_per_mwh": 55.44
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 789744.0,
     "partial": false,
     "purchase_types": [
      "AD",
      "LU"
     ],
     "rows": 2,
     "seller": {
      "id": "org:eia:14624",
      "name": "Grant PUD",
      "relation": "reviewed"
     },
     "seller_name": "grant pud - priest rapids project",
     "tariffs": [],
     "usd": 33374793.0,
     "usd_per_mwh": 42.26
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 685358.0,
     "partial": false,
     "purchase_types": [
      "AD",
      "LU"
     ],
     "rows": 2,
     "seller": null,
     "seller_name": "avangrid renewable (golden hills)",
     "tariffs": [],
     "usd": 31783385.0,
     "usd_per_mwh": 46.37
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 23639.0,
     "partial": false,
     "purchase_types": [
      "LU"
     ],
     "rows": 1,
     "seller": {
      "id": "org:eia:3413",
      "name": "Chelan County PUD",
      "relation": "reviewed"
     },
     "seller_name": "chelan pud slice 38",
     "tariffs": [],
     "usd": 29458093.0,
     "usd_per_mwh": 1246.16
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 0.0,
     "partial": false,
     "purchase_types": [
      "OS"
     ],
     "rows": 1,
     "seller": {
      "id": "org:eia:14624",
      "name": "Grant PUD",
      "relation": "reviewed"
     },
     "seller_name": "grant pud - slice",
     "tariffs": [],
     "usd": 28852311.0,
     "usd_per_mwh": null
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 0.0,
     "partial": false,
     "purchase_types": [
      "OS"
     ],
     "rows": 1,
     "seller": {
      "id": "org:eia:14624",
      "name": "Grant PUD",
      "relation": "reviewed"
     },
     "seller_name": "grant pud - priority",
     "tariffs": [],
     "usd": 28236977.0,
     "usd_per_mwh": null
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 439580.0,
     "partial": false,
     "purchase_types": [
      "LF",
      "OS"
     ],
     "rows": 2,
     "seller": null,
     "seller_name": "morgan stanley cg",
     "tariffs": [],
     "usd": 28014755.0,
     "usd_per_mwh": 63.73
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 3,
       "included": 3,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 3,
       "included": 3,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 440097.0,
     "partial": false,
     "purchase_types": [
      "AD",
      "LF",
      "OS"
     ],
     "rows": 3,
     "seller": {
      "id": "org:eia:1738",
      "name": "Bonneville Power Administration",
      "relation": "reviewed"
     },
     "seller_name": "bonneville power admistration",
     "tariffs": [],
     "usd": 27998333.0,
     "usd_per_mwh": 63.62
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 393115.0,
     "partial": false,
     "purchase_types": [
      "AD",
      "LU"
     ],
     "rows": 2,
     "seller": null,
     "seller_name": "skookumchuck wind ppa",
     "tariffs": [],
     "usd": 19154807.0,
     "usd_per_mwh": 48.73
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 0.0,
     "partial": false,
     "purchase_types": [
      "OS"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "wells fargo (financial)",
     "tariffs": [],
     "usd": -17333719.0,
     "usd_per_mwh": null
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 350317.0,
     "partial": false,
     "purchase_types": [
      "LU"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "kerr dam-energy keeper",
     "tariffs": [],
     "usd": 16639741.0,
     "usd_per_mwh": 47.5
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 383818.0,
     "partial": false,
     "purchase_types": [
      "AD",
      "LU"
     ],
     "rows": 2,
     "seller": null,
     "seller_name": "lund hill solar, llc",
     "tariffs": [],
     "usd": 14436839.0,
     "usd_per_mwh": 37.61
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 221640.0,
     "partial": false,
     "purchase_types": [
      "OS"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "powerex corp.",
     "tariffs": [],
     "usd": 10653324.0,
     "usd_per_mwh": 48.07
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 121976.0,
     "partial": false,
     "purchase_types": [
      "AD",
      "LU"
     ],
     "rows": 2,
     "seller": null,
     "seller_name": "avangrid renewables (klondike wind power iii)",
     "tariffs": [],
     "usd": 9366094.0,
     "usd_per_mwh": 76.79
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 11853.0,
     "partial": false,
     "purchase_types": [
      "LU"
     ],
     "rows": 1,
     "seller": {
      "id": "org:eia:3413",
      "name": "Chelan County PUD",
      "relation": "reviewed"
     },
     "seller_name": "chelan pud slice 35",
     "tariffs": [],
     "usd": 8248231.0,
     "usd_per_mwh": 695.88
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 0.0,
     "partial": false,
     "purchase_types": [
      "OS"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "morgan stanley cg (financial)",
     "tariffs": [],
     "usd": 7462488.0,
     "usd_per_mwh": null
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 0.0,
     "partial": false,
     "purchase_types": [
      "OS"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "merrill lynch comm (financial)",
     "tariffs": [],
     "usd": 6808276.0,
     "usd_per_mwh": null
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 129737.0,
     "partial": false,
     "purchase_types": [
      "AD",
      "LU"
     ],
     "rows": 2,
     "seller": {
      "id": "org:eia:17164",
      "name": "Sierra Pacific Industries Inc",
      "relation": "reviewed"
     },
     "seller_name": "sierra pacific industries",
     "tariffs": [],
     "usd": 6158399.0,
     "usd_per_mwh": 47.47
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 0.0,
     "partial": false,
     "purchase_types": [
      "OS"
     ],
     "rows": 1,
     "seller": {
      "id": "org:eia:14624",
      "name": "Grant PUD",
      "relation": "reviewed"
     },
     "seller_name": "grant pud - eweb mp",
     "tariffs": [],
     "usd": 6016595.0,
     "usd_per_mwh": null
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 267870.0,
     "partial": false,
     "purchase_types": [
      "LU"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "freddy 1 tolling",
     "tariffs": [],
     "usd": 4990181.0,
     "usd_per_mwh": 18.63
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 0.0,
     "partial": false,
     "purchase_types": [
      "OS"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "mitsui bussan (financial)",
     "tariffs": [],
     "usd": 3607301.0,
     "usd_per_mwh": null
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 59297.0,
     "partial": false,
     "purchase_types": [
      "LU"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "twin falls hydro",
     "tariffs": [],
     "usd": 3058978.0,
     "usd_per_mwh": 51.59
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 32337.0,
     "partial": false,
     "purchase_types": [
      "LU"
     ],
     "rows": 1,
     "seller": {
      "id": "org:eia:63987",
      "name": "Koma Kulshan Associates",
      "relation": "reviewed"
     },
     "seller_name": "koma kulshan associates",
     "tariffs": [],
     "usd": 2758973.0,
     "usd_per_mwh": 85.32
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 33392.0,
     "partial": false,
     "purchase_types": [
      "LU"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "emerald city renewables, llc",
     "tariffs": [],
     "usd": 2583176.0,
     "usd_per_mwh": 77.36
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 53498.0,
     "partial": false,
     "purchase_types": [
      "LU"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "vantage wind farm",
     "tariffs": [],
     "usd": 2352577.0,
     "usd_per_mwh": 43.98
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 45540.0,
     "partial": false,
     "purchase_types": [
      "OS"
     ],
     "rows": 1,
     "seller": {
      "id": "org:eia:16868",
      "name": "Seattle City Light",
      "relation": "reviewed"
     },
     "seller_name": "seattle city light marketing",
     "tariffs": [],
     "usd": 2011698.0,
     "usd_per_mwh": 44.17
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 20185.0,
     "partial": false,
     "purchase_types": [
      "IF"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "powerex (point roberts)",
     "tariffs": [],
     "usd": 1937668.0,
     "usd_per_mwh": 96.0
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 45775.0,
     "partial": false,
     "purchase_types": [
      "OS"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "transalta energy marketing",
     "tariffs": [],
     "usd": 1658973.0,
     "usd_per_mwh": 36.24
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 49890.0,
     "partial": false,
     "purchase_types": [
      "OS"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "stateline wind",
     "tariffs": [],
     "usd": 1585704.0,
     "usd_per_mwh": 31.78
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 47274.0,
     "partial": false,
     "purchase_types": [
      "OS"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "avangrid power",
     "tariffs": [],
     "usd": 1496132.0,
     "usd_per_mwh": 31.65
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 40047.0,
     "partial": false,
     "purchase_types": [
      "AD",
      "OS"
     ],
     "rows": 2,
     "seller": null,
     "seller_name": "dynasty power inc",
     "tariffs": [],
     "usd": 1257774.0,
     "usd_per_mwh": 31.41
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 20173.0,
     "partial": false,
     "purchase_types": [
      "LU"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "puget sound hydro (nooksack)",
     "tariffs": [],
     "usd": 1216220.0,
     "usd_per_mwh": 60.29
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 34241.0,
     "partial": false,
     "purchase_types": [
      "AD",
      "OS"
     ],
     "rows": 2,
     "seller": null,
     "seller_name": "the energy authority",
     "tariffs": [],
     "usd": 1134317.0,
     "usd_per_mwh": 33.13
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 24834.0,
     "partial": false,
     "purchase_types": [
      "OS"
     ],
     "rows": 1,
     "seller": {
      "id": "org:eia:15248",
      "name": "Portland General Electric",
      "relation": "reviewed"
     },
     "seller_name": "portland general electric",
     "tariffs": [],
     "usd": 1072131.0,
     "usd_per_mwh": 43.17
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 0.0,
     "partial": false,
     "purchase_types": [
      "IU"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "klickitat pud",
     "tariffs": [],
     "usd": 1045475.0,
     "usd_per_mwh": null
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 34990.0,
     "partial": false,
     "purchase_types": [
      "AD",
      "OS"
     ],
     "rows": 2,
     "seller": null,
     "seller_name": "conoco, inc.",
     "tariffs": [],
     "usd": 944465.0,
     "usd_per_mwh": 26.99
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 11467.0,
     "partial": false,
     "purchase_types": [
      "LU"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "urtica solar",
     "tariffs": [],
     "usd": 876274.0,
     "usd_per_mwh": 76.42
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 11234.0,
     "partial": false,
     "purchase_types": [
      "LU"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "penstemon solar",
     "tariffs": [],
     "usd": 858520.0,
     "usd_per_mwh": 76.42
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 10775.0,
     "partial": false,
     "purchase_types": [
      "LU"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "camas solar",
     "tariffs": [],
     "usd": 823403.0,
     "usd_per_mwh": 76.42
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 17070.0,
     "partial": false,
     "purchase_types": [
      "OS"
     ],
     "rows": 1,
     "seller": {
      "id": "org:eia:20169",
      "name": "Avista",
      "relation": "reviewed"
     },
     "seller_name": "avista corp. wwp division",
     "tariffs": [],
     "usd": 779209.0,
     "usd_per_mwh": 45.65
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 10592.0,
     "partial": false,
     "purchase_types": [
      "IU"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "south fork ii associates(weeks falls)",
     "tariffs": [],
     "usd": 638590.0,
     "usd_per_mwh": 60.29
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 13410.0,
     "partial": false,
     "purchase_types": [
      "OS"
     ],
     "rows": 1,
     "seller": {
      "id": "org:eia:14354",
      "name": "PacifiCorp",
      "relation": "reviewed"
     },
     "seller_name": "pacificorp",
     "tariffs": [],
     "usd": 593158.0,
     "usd_per_mwh": 44.23
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 0.0,
     "partial": false,
     "purchase_types": [
      "EX"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "avista nichols pump",
     "tariffs": [],
     "usd": 515668.0,
     "usd_per_mwh": null
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 6.0,
     "partial": false,
     "purchase_types": [
      "AD",
      "OS"
     ],
     "rows": 2,
     "seller": {
      "id": "org:eia:14624",
      "name": "Grant PUD",
      "relation": "reviewed"
     },
     "seller_name": "grant county pud #2",
     "tariffs": [],
     "usd": 500191.0,
     "usd_per_mwh": 83365.17
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 8717.0,
     "partial": false,
     "purchase_types": [
      "LU"
     ],
     "rows": 1,
     "seller": {
      "id": "org:eia:1784",
      "name": "Black Creek Hydro Inc",
      "relation": "reviewed"
     },
     "seller_name": "black creek hydro",
     "tariffs": [],
     "usd": 472960.0,
     "usd_per_mwh": 54.26
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 7605.0,
     "partial": false,
     "purchase_types": [
      "OS"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "vitol inc.",
     "tariffs": [],
     "usd": 459866.0,
     "usd_per_mwh": 60.47
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 10214.0,
     "partial": false,
     "purchase_types": [
      "OS"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "cp energy marketing (epcor)",
     "tariffs": [],
     "usd": 457966.0,
     "usd_per_mwh": 44.84
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 11295.0,
     "partial": false,
     "purchase_types": [
      "OS"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "shell energy (coral pwr)",
     "tariffs": [],
     "usd": 393715.0,
     "usd_per_mwh": 34.86
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 13509.0,
     "partial": false,
     "purchase_types": [
      "AD",
      "OS"
     ],
     "rows": 2,
     "seller": {
      "id": "org:eia:18429",
      "name": "Tacoma Power",
      "relation": "reviewed"
     },
     "seller_name": "tacoma power",
     "tariffs": [],
     "usd": 348942.0,
     "usd_per_mwh": 25.83
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 2,
       "included": 2,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 11099.0,
     "partial": false,
     "purchase_types": [
      "AD",
      "OS"
     ],
     "rows": 2,
     "seller": null,
     "seller_name": "constellation energy",
     "tariffs": [],
     "usd": 334225.0,
     "usd_per_mwh": 30.11
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 3095.0,
     "partial": false,
     "purchase_types": [
      "IU"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "edaleen dairy, llc",
     "tariffs": [],
     "usd": 186606.0,
     "usd_per_mwh": 60.29
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 3643.0,
     "partial": false,
     "purchase_types": [
      "OS"
     ],
     "rows": 1,
     "seller": {
      "id": "org:eia:13902",
      "name": "NorthWestern Energy",
      "relation": "reviewed"
     },
     "seller_name": "northwestern energy",
     "tariffs": [],
     "usd": 157167.0,
     "usd_per_mwh": 43.14
    },
    {
     "coverage": {
      "mwh": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      },
      "usd": {
       "eligible": 1,
       "included": 1,
       "unit": "counterparty rows"
      }
     },
     "edge": "M7",
     "mwh": 2887.0,
     "partial": false,
     "purchase_types": [
      "IU"
     ],
     "rows": 1,
     "seller": null,
     "seller_name": "swauk wind llc",
     "tariffs": [],
     "usd": 148043.0,
     "usd_per_mwh": 51.28
    }
   ],
   "sellers_total": 95,
   "source_ref": "pudl-ferc1-purchased-power"
  },
  "report_year": 2025,
  "revenue_by_class": {
   "note": "Schedule 300 class lines as the form computes them (as_computed); usd_per_mwh is revenue over MWh sold for that class; the class lines are not re-summed here; EIA-861 revenue and price for the same utility are on the retail block and can differ (different survey, scope and year)",
   "rows": [
    {
     "as_computed": true,
     "customers": 1104338.0,
     "edge": "M4",
     "ferc_account": "440",
     "mwh": 11434185.0,
     "revenue_type": "residential_sales",
     "usd": 1944566138.0,
     "usd_per_mwh": 170.07
    },
    {
     "as_computed": true,
     "customers": 135533.0,
     "edge": "M4",
     "ferc_account": null,
     "mwh": 8649567.0,
     "revenue_type": "small_or_commercial",
     "usd": 1352174424.0,
     "usd_per_mwh": 156.33
    },
    {
     "as_computed": true,
     "customers": 3158.0,
     "edge": "M4",
     "ferc_account": null,
     "mwh": 1040902.0,
     "revenue_type": "large_or_industrial",
     "usd": 151263982.0,
     "usd_per_mwh": 145.32
    },
    {
     "as_computed": true,
     "customers": 8414.0,
     "edge": "M4",
     "ferc_account": "444",
     "mwh": 69979.0,
     "revenue_type": "public_street_and_highway_lighting",
     "usd": 25686397.0,
     "usd_per_mwh": 367.06
    },
    {
     "as_computed": true,
     "customers": 9.0,
     "edge": "M7-sell",
     "ferc_account": "447",
     "mwh": 9500294.0,
     "revenue_type": "sales_for_resale",
     "usd": 375516235.0,
     "usd_per_mwh": 39.53
    }
   ],
   "source_ref": "pudl-ferc1-operating-revenues",
   "totals": [
    {
     "mwh": null,
     "revenue_type": "electric_operating_revenues",
     "usd": 3935546817.0
    },
    {
     "mwh": null,
     "revenue_type": "other_operating_revenues",
     "usd": 93183346.0
    },
    {
     "mwh": 30694927.0,
     "revenue_type": "sales_of_electricity",
     "usd": 3849207176.0
    },
    {
     "mwh": 21194633.0,
     "revenue_type": "sales_to_ultimate_consumers",
     "usd": 3473690941.0
    }
   ]
  },
  "years": [
   2015,
   2016,
   2017,
   2018,
   2019,
   2020,
   2021,
   2022,
   2023,
   2024,
   2025
  ]
 },
 "name": "Puget Sound Energy",
 "obligations": {
  "available": true,
  "checked": "2026-09-27",
  "coverage": {
   "assertions": 41,
   "kinds_present": [
    "applicability",
    "deciding_event",
    "determination",
    "filed_achievement",
    "target"
   ],
   "programs": 2,
   "review_due": 0
  },
  "note": "Five kinds kept apart: what applies, what is owed, what the utility filed, what the issuing body decided, and the open proceeding. The disclosed-supply block above is the same utility's fuel mix as Commerce computed it; read it beside these rows, never as a verdict on them. Rows checked through 2026-09-27; a row past its review date is marked, not removed.",
  "programs": [
   {
    "applicability": {
     "as_of": "2019-05-07",
     "assertion_id": "ceta-15500-applicability",
     "basis": null,
     "curation": {
      "checked": "2026-09-21",
      "review_after": "2027-07-01",
      "review_due": false,
      "reviewer": "claude-w14"
     },
     "docket": null,
     "document": "RCW 19.405.020 Definitions; RCW 19.405.060 Clean energy implementation plans",
     "evidence": "reported",
     "fact": null,
     "issuer": "Washington State Legislature",
     "kind": "applicability",
     "locator": "19.405.020(14) and (23); 19.405.060(1)(a)",
     "method": "curated",
     "metric": null,
     "missing_reason": null,
     "next_step": null,
     "next_step_date": null,
     "note": "\"'Electric utility' or 'utility' means a consumer-owned utility or an investor-owned utility\" (14); \"'Investor-owned utility' means a company owned by investors that meets the definition of 'corporation' in RCW 80.04.010 and is engaged in distributing electricity to more than one retail electric customer in the state\" (23). RCW 19.405.060(1)(a): \"By January 1, 2022, and every four years thereafter, each investor-owned utility must develop and submit to the commission: (i) A four-year clean energy implementation plan ... and (ii) Proposed interim targets\". Chapter effective 2019-05-07 (2019 c 288, E2SSB 5116). PSE files in EIA-861 as an investor-owned utility.",
     "participation_url": null,
     "percent_decimals": null,
     "period": {
      "as_of": "2019-05-07",
      "kind": "instant",
      "label": "2019-05-07"
     },
     "source_publisher": "Washington State Legislature",
     "source_ref": "clean-energy-obligations",
     "source_url": "https://app.leg.wa.gov/RCW/default.aspx?cite=19.405.020",
     "standing": "enacted",
     "state": "WA",
     "statement": "investor-owned electric utility subject to the Clean Energy Transformation Act; files its clean energy implementation plan with the commission",
     "unit": null,
     "value": null
    },
    "applicability_all": [
     {
      "as_of": "2019-05-07",
      "assertion_id": "ceta-15500-applicability",
      "basis": null,
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": null,
      "document": "RCW 19.405.020 Definitions; RCW 19.405.060 Clean energy implementation plans",
      "evidence": "reported",
      "fact": null,
      "issuer": "Washington State Legislature",
      "kind": "applicability",
      "locator": "19.405.020(14) and (23); 19.405.060(1)(a)",
      "method": "curated",
      "metric": null,
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "\"'Electric utility' or 'utility' means a consumer-owned utility or an investor-owned utility\" (14); \"'Investor-owned utility' means a company owned by investors that meets the definition of 'corporation' in RCW 80.04.010 and is engaged in distributing electricity to more than one retail electric customer in the state\" (23). RCW 19.405.060(1)(a): \"By January 1, 2022, and every four years thereafter, each investor-owned utility must develop and submit to the commission: (i) A four-year clean energy implementation plan ... and (ii) Proposed interim targets\". Chapter effective 2019-05-07 (2019 c 288, E2SSB 5116). PSE files in EIA-861 as an investor-owned utility.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2019-05-07",
       "kind": "instant",
       "label": "2019-05-07"
      },
      "source_publisher": "Washington State Legislature",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://app.leg.wa.gov/RCW/default.aspx?cite=19.405.020",
      "standing": "enacted",
      "state": "WA",
      "statement": "investor-owned electric utility subject to the Clean Energy Transformation Act; files its clean energy implementation plan with the commission",
      "unit": null,
      "value": null
     }
    ],
    "applicability_rows": 1,
    "comparisons": [],
    "deciding_events": [
     {
      "as_of": "2026-07-07",
      "assertion_id": "ceta-15500-event-ccr-comments-2026",
      "basis": null,
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2026-10-21",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-210795",
      "document": "Notice of Opportunity to File Written Comments (Due By Tuesday, October 20, 2026, by 5:00 p.m.)",
      "evidence": "reported",
      "fact": null,
      "issuer": "Washington Utilities and Transportation Commission",
      "kind": "deciding_event",
      "locator": "pages 1-2",
      "method": "curated",
      "metric": null,
      "missing_reason": null,
      "next_step": "written comments due to the commission by 5:00 p.m.",
      "next_step_date": "2026-10-20",
      "note": "\"The Commission would like to hear from you to what extent PSE's Clean Energy Compliance Report demonstrates whether PSE has made progress towards the goals of its CEIP.\" Submit online (Consumer Protection web portal), by email to comments@utc.wa.gov, or by mail; cite Docket UE-210795. Comments are posted publicly.",
      "participation_url": "https://www.utc.wa.gov/consumers/submit-comment",
      "percent_decimals": null,
      "period": {
       "as_of": "2026-07-07",
       "end_year": 2025,
       "kind": "obligation_period",
       "label": "2022-2025",
       "start_year": 2022
      },
      "source_publisher": "Washington Utilities and Transportation Commission",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=1574&year=2021&docketNumber=210795",
      "standing": "open",
      "state": "WA",
      "statement": "commission review of PSE's 2026 Clean Energy Compliance Report: written comments invited",
      "unit": null,
      "value": null
     }
    ],
    "determinations": [
     {
      "as_of": "2023-06-06",
      "assertion_id": "ceta-15500-determination-order-08",
      "basis": null,
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-210795",
      "document": "Final Order 08 Approving Clean Energy Implementation Plan Subject to Conditions",
      "evidence": "reported",
      "fact": null,
      "issuer": "Washington Utilities and Transportation Commission",
      "kind": "determination",
      "locator": "paragraphs 48 and 54",
      "method": "curated",
      "metric": null,
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "\"We approve the Company's Interim Targets subject to conditions recommended by Public Counsel. As required by RCW 19.405.060(1)(a)(ii) and WAC 480-100-640(2)(a)(i), PSE's Interim Targets demonstrate how the Company will make reasonable progress towards CETA's clean energy requirements.\" Effective 2023-06-06 (entered 2023-06-05; conditions in Appendix A).",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2023-06-06",
       "kind": "instant",
       "label": "2023-06-06"
      },
      "source_publisher": "Washington Utilities and Transportation Commission",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=1016&year=2021&docketNumber=210795",
      "standing": "ordered",
      "state": "WA",
      "statement": "final order approving the 2021 clean energy implementation plan subject to conditions",
      "unit": null,
      "value": null
     },
     {
      "as_of": "2024-03-25",
      "assertion_id": "ceta-15500-determination-order-12",
      "basis": null,
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-210795",
      "document": "Order 12 Approving CEIP Biennial Update Subject to Conditions",
      "evidence": "reported",
      "fact": null,
      "issuer": "Washington Utilities and Transportation Commission",
      "kind": "determination",
      "locator": "conditions (1)(a)-(c), (2), (3)",
      "method": "curated",
      "metric": null,
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "Approved at the recessed open meeting of 2024-03-22; effective 2024-03-25. PSE \"requested that the Commission clarify whether the Interim Targets may be expressed as a four-year average\" and asked to lower 2025 from 63 to 60 percent; condition (1) kept the annual series.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2024-03-25",
       "kind": "instant",
       "label": "2024-03-25"
      },
      "source_publisher": "Washington Utilities and Transportation Commission",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=1262&year=2021&docketNumber=210795",
      "standing": "ordered",
      "state": "WA",
      "statement": "order approving the 2023 biennial CEIP update subject to conditions, keeping the annual interim targets",
      "unit": null,
      "value": null
     },
     {
      "as_of": "2024-07-11",
      "assertion_id": "ceta-15500-determination-order-13",
      "basis": null,
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-210795",
      "document": "Order 13 Granting Petition to Amend Orders 8 and 12",
      "evidence": "reported",
      "fact": null,
      "issuer": "Washington Utilities and Transportation Commission",
      "kind": "determination",
      "locator": "paragraphs 4 and 10",
      "method": "curated",
      "metric": null,
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "\"PSE is no longer required to file a 2025 CEIP, subject to the conditions described in Dockets UG-240434 and UE-240433\"; granted \"subject to the condition that PSE fulfill the commitments it made in its June 27, 2024, filing\". Basis: ESHB 1589.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2024-07-11",
       "kind": "instant",
       "label": "2024-07-11"
      },
      "source_publisher": "Washington Utilities and Transportation Commission",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=1309&year=2021&docketNumber=210795",
      "standing": "ordered",
      "state": "WA",
      "statement": "order amending Orders 08 and 12: PSE no longer required to file a 2025 CEIP; planning consolidated into a 2027 Integrated System Plan",
      "unit": null,
      "value": null
     },
     {
      "as_of": "2024-11-08",
      "assertion_id": "ceta-15500-determination-order-14",
      "basis": null,
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-210795",
      "document": "Order 14 Denying Petition to Amend Orders 8 and 12",
      "evidence": "reported",
      "fact": null,
      "issuer": "Washington Utilities and Transportation Commission",
      "kind": "determination",
      "locator": "paragraph 18(1)",
      "method": "curated",
      "metric": null,
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "Open meeting 2024-11-07 (2:1); effective 2024-11-08. The order keeps the targets while saying \"rote adherence to interim targets is not anticipated\" and that the compliance review will consider the circumstances.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2024-11-08",
       "kind": "instant",
       "label": "2024-11-08"
      },
      "source_publisher": "Washington Utilities and Transportation Commission",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=1377&year=2021&docketNumber=210795",
      "standing": "ordered",
      "state": "WA",
      "statement": "order denying the petition to lower the 2024 and 2025 interim targets to 48 percent",
      "unit": null,
      "value": null
     },
     {
      "as_of": "2026-09-21",
      "assertion_id": "ceta-15500-determination-ccr-2022-2025",
      "basis": null,
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2026-10-21",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-210795",
      "document": "Docket UE-210795 orders list",
      "evidence": "reported",
      "fact": null,
      "issuer": "Washington Utilities and Transportation Commission",
      "kind": "determination",
      "locator": "latest order is Order 14 of 2024-11-08",
      "method": "curated",
      "metric": null,
      "missing_reason": "not_yet_decided",
      "next_step": null,
      "next_step_date": null,
      "note": "No order on the compliance report as of 2026-09-21. The commission opened written comments (due 2026-10-20) and will decide whether PSE complied with its interim targets for the first implementation period; the report's 50.6 percent is the utility's figure, not a finding.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2026-09-21",
       "end_year": 2025,
       "kind": "obligation_period",
       "label": "2022-2025",
       "start_year": 2022
      },
      "source_publisher": "Washington Utilities and Transportation Commission",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://www.utc.wa.gov/casedocket/2021/210795/orders",
      "standing": null,
      "state": "WA",
      "statement": "commission decision on the 2026 Clean Energy Compliance Report",
      "unit": null,
      "value": null
     }
    ],
    "filed_achievements": [
     {
      "as_of": "2026-07-01",
      "assertion_id": "ceta-15500-filed-clean-energy-mwh-2022-2025",
      "basis": "CETA-eligible energy, 2022-2025 sum",
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-210795",
      "document": "2026 Clean Energy Compliance Report for the 2022-2025 implementation period (filed 2026-07-01; substituted 2026-07-06)",
      "evidence": "reported",
      "fact": {
       "basis": "CETA-eligible energy, 2022-2025 sum",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/ceta-15500-filed-clean-energy-mwh-2022-2025#policy_filed_mwh",
       "label": "electricity supplied from renewable and nonemitting resources over the implementation period, as reported by the utility",
       "locator": "ceta-15500-filed-clean-energy-mwh-2022-2025; 2026 Clean Energy Compliance Report for the 2022-2025 implementation period (filed 2026-07-01; substituted 2026-07-06); Section 2, paragraph before Table 4; Table 5",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_filed_mwh",
       "missing_reason": null,
       "note": "\"From 2022-2025, PSE supplied 40,185,529 MWh from renewable and nonemitting resources, which exceeds the 40,070,388 MWh PSE projected would be necessary to achieve the interim target.\" Load grew faster than forecast, so the MWh exceeded the plan while the share did not.",
       "period": {
        "as_of": "2026-07-01",
        "end_year": 2025,
        "kind": "obligation_period",
        "label": "2022-2025",
        "start_year": 2022
       },
       "precision": 0,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "MWh",
       "value": 40185529.0
      },
      "issuer": "Puget Sound Energy",
      "kind": "filed_achievement",
      "locator": "Section 2, paragraph before Table 4; Table 5",
      "method": "curated",
      "metric": "clean_energy_mwh",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "\"From 2022-2025, PSE supplied 40,185,529 MWh from renewable and nonemitting resources, which exceeds the 40,070,388 MWh PSE projected would be necessary to achieve the interim target.\" Load grew faster than forecast, so the MWh exceeded the plan while the share did not.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2026-07-01",
       "end_year": 2025,
       "kind": "obligation_period",
       "label": "2022-2025",
       "start_year": 2022
      },
      "source_publisher": "Puget Sound Energy",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=1571&year=2021&docketNumber=210795",
      "standing": "filed",
      "state": "WA",
      "statement": "electricity supplied from renewable and nonemitting resources over the implementation period, as reported by the utility",
      "unit": "MWh",
      "value": 40185529.0
     },
     {
      "as_of": "2026-07-01",
      "assertion_id": "ceta-15500-filed-clean-share-2022",
      "basis": "CETA-eligible energy divided by CETA retail load (retail sales less load reduction)",
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-210795",
      "document": "2026 Clean Energy Compliance Report for the 2022-2025 implementation period (filed 2026-07-01; substituted 2026-07-06)",
      "evidence": "reported",
      "fact": {
       "basis": "CETA-eligible energy divided by CETA retail load (retail sales less load reduction)",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/ceta-15500-filed-clean-share-2022#policy_filed_share",
       "label": "share of retail electric load served with clean energy, as reported by the utility",
       "locator": "ceta-15500-filed-clean-share-2022; 2026 Clean Energy Compliance Report for the 2022-2025 implementation period (filed 2026-07-01; substituted 2026-07-06); Section 2, Table 6 (Comparison of retail sales, energy, and percentage), row Actual",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_filed_share",
       "missing_reason": null,
       "note": "Table 6 column \"CETA percentage (CETA-eligible energy / CETA retail load)\". Table 3 prints 44.3% for 2022 with a footnote; Table 6 is used here.",
       "period": {
        "as_of": "2026-07-01",
        "end_year": 2022,
        "kind": "obligation_period",
        "label": "2022",
        "start_year": 2022
       },
       "precision": 1,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "percent",
       "value": 44.2
      },
      "issuer": "Puget Sound Energy",
      "kind": "filed_achievement",
      "locator": "Section 2, Table 6 (Comparison of retail sales, energy, and percentage), row Actual",
      "method": "curated",
      "metric": "clean_share_of_retail_load",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "Table 6 column \"CETA percentage (CETA-eligible energy / CETA retail load)\". Table 3 prints 44.3% for 2022 with a footnote; Table 6 is used here.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2026-07-01",
       "end_year": 2022,
       "kind": "obligation_period",
       "label": "2022",
       "start_year": 2022
      },
      "source_publisher": "Puget Sound Energy",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=1571&year=2021&docketNumber=210795",
      "standing": "filed",
      "state": "WA",
      "statement": "share of retail electric load served with clean energy, as reported by the utility",
      "unit": "percent",
      "value": 44.2
     },
     {
      "as_of": "2026-07-01",
      "assertion_id": "ceta-15500-filed-clean-share-2022-2025",
      "basis": "CETA-eligible energy divided by CETA retail load (retail sales less load reduction), 2022-2025 average",
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-210795",
      "document": "2026 Clean Energy Compliance Report for the 2022-2025 implementation period (filed 2026-07-01; substituted 2026-07-06)",
      "evidence": "reported",
      "fact": {
       "basis": "CETA-eligible energy divided by CETA retail load (retail sales less load reduction), 2022-2025 average",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/ceta-15500-filed-clean-share-2022-2025#policy_filed_share",
       "label": "share of retail electric load served with clean energy, four-year average, as reported by the utility",
       "locator": "ceta-15500-filed-clean-share-2022-2025; 2026 Clean Energy Compliance Report for the 2022-2025 implementation period (filed 2026-07-01; substituted 2026-07-06); Section 2 Interim targets, Table 3 and closing paragraph",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_filed_share",
       "missing_reason": null,
       "note": "\"PSE served an average of 50.6% of retail electric load with clean energy\"; \"PSE's actual four-year average of 50.6% clean and nonemitting energy was less than the four-year interim target of 54.5%\", and PSE \"concludes that its actions during the implementation period reflect reasonable and sufficient progress\". The report also states the incremental cost \"slightly exceeded the 2% incremental cost threshold per WAC 480-100-660\". The utility's own account; the commission has not yet decided on it. Copy on PSE's library: https://www.cleanenergyplan.pse.com/library",
       "period": {
        "as_of": "2026-07-01",
        "end_year": 2025,
        "kind": "obligation_period",
        "label": "2022-2025",
        "start_year": 2022
       },
       "precision": 1,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "percent",
       "value": 50.6
      },
      "issuer": "Puget Sound Energy",
      "kind": "filed_achievement",
      "locator": "Section 2 Interim targets, Table 3 and closing paragraph",
      "method": "curated",
      "metric": "clean_share_of_retail_load",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "\"PSE served an average of 50.6% of retail electric load with clean energy\"; \"PSE's actual four-year average of 50.6% clean and nonemitting energy was less than the four-year interim target of 54.5%\", and PSE \"concludes that its actions during the implementation period reflect reasonable and sufficient progress\". The report also states the incremental cost \"slightly exceeded the 2% incremental cost threshold per WAC 480-100-660\". The utility's own account; the commission has not yet decided on it. Copy on PSE's library: https://www.cleanenergyplan.pse.com/library",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2026-07-01",
       "end_year": 2025,
       "kind": "obligation_period",
       "label": "2022-2025",
       "start_year": 2022
      },
      "source_publisher": "Puget Sound Energy",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=1571&year=2021&docketNumber=210795",
      "standing": "filed",
      "state": "WA",
      "statement": "share of retail electric load served with clean energy, four-year average, as reported by the utility",
      "unit": "percent",
      "value": 50.6
     },
     {
      "as_of": "2026-07-01",
      "assertion_id": "ceta-15500-filed-clean-share-2023",
      "basis": "CETA-eligible energy divided by CETA retail load (retail sales less load reduction)",
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-210795",
      "document": "2026 Clean Energy Compliance Report for the 2022-2025 implementation period (filed 2026-07-01; substituted 2026-07-06)",
      "evidence": "reported",
      "fact": {
       "basis": "CETA-eligible energy divided by CETA retail load (retail sales less load reduction)",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/ceta-15500-filed-clean-share-2023#policy_filed_share",
       "label": "share of retail electric load served with clean energy, as reported by the utility",
       "locator": "ceta-15500-filed-clean-share-2023; 2026 Clean Energy Compliance Report for the 2022-2025 implementation period (filed 2026-07-01; substituted 2026-07-06); Section 2, Table 6 (Comparison of retail sales, energy, and percentage), row Actual",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_filed_share",
       "missing_reason": null,
       "note": "Table 6 column \"CETA percentage (CETA-eligible energy / CETA retail load)\".",
       "period": {
        "as_of": "2026-07-01",
        "end_year": 2023,
        "kind": "obligation_period",
        "label": "2023",
        "start_year": 2023
       },
       "precision": 1,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "percent",
       "value": 48.0
      },
      "issuer": "Puget Sound Energy",
      "kind": "filed_achievement",
      "locator": "Section 2, Table 6 (Comparison of retail sales, energy, and percentage), row Actual",
      "method": "curated",
      "metric": "clean_share_of_retail_load",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "Table 6 column \"CETA percentage (CETA-eligible energy / CETA retail load)\".",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2026-07-01",
       "end_year": 2023,
       "kind": "obligation_period",
       "label": "2023",
       "start_year": 2023
      },
      "source_publisher": "Puget Sound Energy",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=1571&year=2021&docketNumber=210795",
      "standing": "filed",
      "state": "WA",
      "statement": "share of retail electric load served with clean energy, as reported by the utility",
      "unit": "percent",
      "value": 48.0
     },
     {
      "as_of": "2026-07-01",
      "assertion_id": "ceta-15500-filed-clean-share-2024",
      "basis": "CETA-eligible energy divided by CETA retail load (retail sales less load reduction)",
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-210795",
      "document": "2026 Clean Energy Compliance Report for the 2022-2025 implementation period (filed 2026-07-01; substituted 2026-07-06)",
      "evidence": "reported",
      "fact": {
       "basis": "CETA-eligible energy divided by CETA retail load (retail sales less load reduction)",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/ceta-15500-filed-clean-share-2024#policy_filed_share",
       "label": "share of retail electric load served with clean energy, as reported by the utility",
       "locator": "ceta-15500-filed-clean-share-2024; 2026 Clean Energy Compliance Report for the 2022-2025 implementation period (filed 2026-07-01; substituted 2026-07-06); Section 2, Table 6 (Comparison of retail sales, energy, and percentage), row Actual",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_filed_share",
       "missing_reason": null,
       "note": "Table 6 column \"CETA percentage (CETA-eligible energy / CETA retail load)\".",
       "period": {
        "as_of": "2026-07-01",
        "end_year": 2024,
        "kind": "obligation_period",
        "label": "2024",
        "start_year": 2024
       },
       "precision": 1,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "percent",
       "value": 52.7
      },
      "issuer": "Puget Sound Energy",
      "kind": "filed_achievement",
      "locator": "Section 2, Table 6 (Comparison of retail sales, energy, and percentage), row Actual",
      "method": "curated",
      "metric": "clean_share_of_retail_load",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "Table 6 column \"CETA percentage (CETA-eligible energy / CETA retail load)\".",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2026-07-01",
       "end_year": 2024,
       "kind": "obligation_period",
       "label": "2024",
       "start_year": 2024
      },
      "source_publisher": "Puget Sound Energy",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=1571&year=2021&docketNumber=210795",
      "standing": "filed",
      "state": "WA",
      "statement": "share of retail electric load served with clean energy, as reported by the utility",
      "unit": "percent",
      "value": 52.7
     },
     {
      "as_of": "2026-07-01",
      "assertion_id": "ceta-15500-filed-clean-share-2025",
      "basis": "CETA-eligible energy divided by CETA retail load (retail sales less load reduction)",
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-210795",
      "document": "2026 Clean Energy Compliance Report for the 2022-2025 implementation period (filed 2026-07-01; substituted 2026-07-06)",
      "evidence": "reported",
      "fact": {
       "basis": "CETA-eligible energy divided by CETA retail load (retail sales less load reduction)",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/ceta-15500-filed-clean-share-2025#policy_filed_share",
       "label": "share of retail electric load served with clean energy, as reported by the utility",
       "locator": "ceta-15500-filed-clean-share-2025; 2026 Clean Energy Compliance Report for the 2022-2025 implementation period (filed 2026-07-01; substituted 2026-07-06); Section 2, Table 6 (Comparison of retail sales, energy, and percentage), row Actual",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_filed_share",
       "missing_reason": null,
       "note": "Table 6 column \"CETA percentage (CETA-eligible energy / CETA retail load)\".",
       "period": {
        "as_of": "2026-07-01",
        "end_year": 2025,
        "kind": "obligation_period",
        "label": "2025",
        "start_year": 2025
       },
       "precision": 1,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "percent",
       "value": 57.4
      },
      "issuer": "Puget Sound Energy",
      "kind": "filed_achievement",
      "locator": "Section 2, Table 6 (Comparison of retail sales, energy, and percentage), row Actual",
      "method": "curated",
      "metric": "clean_share_of_retail_load",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "Table 6 column \"CETA percentage (CETA-eligible energy / CETA retail load)\".",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2026-07-01",
       "end_year": 2025,
       "kind": "obligation_period",
       "label": "2025",
       "start_year": 2025
      },
      "source_publisher": "Puget Sound Energy",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=1571&year=2021&docketNumber=210795",
      "standing": "filed",
      "state": "WA",
      "statement": "share of retail electric load served with clean energy, as reported by the utility",
      "unit": "percent",
      "value": 57.4
     }
    ],
    "instrument": "Clean energy implementation plan every four years (RCW 19.405.060) with interim targets; coal out of the allocation by 2025-12-31, greenhouse gas neutral retail sales from 2030-01-01, 100 percent renewable or nonemitting by 2045-01-01",
    "issuing_body": "Washington Utilities and Transportation Commission",
    "kinds_checked_absent": [
     "determination",
     "target"
    ],
    "kinds_present": [
     "applicability",
     "deciding_event",
     "determination",
     "filed_achievement",
     "target"
    ],
    "name": "Clean Energy Transformation Act",
    "program_id": "ceta",
    "review_due": 0,
    "statute": "RCW 19.405",
    "statute_url": "https://app.leg.wa.gov/RCW/default.aspx?cite=19.405",
    "targets": [
     {
      "as_of": "2023-11-20",
      "assertion_id": "ceta-15500-target-clean-share-of-retail-load-2022-2025",
      "basis": "of retail electric load",
      "curation": {
       "checked": "2026-09-18",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-4b4"
      },
      "docket": "UE-210795",
      "document": "PSE 2023 Biennial Clean Energy Implementation Plan Update",
      "evidence": "reported",
      "fact": {
       "basis": "of retail electric load",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/ceta-15500-target-clean-share-of-retail-load-2022-2025#policy_target_share",
       "label": "interim target for the 2022-2025 compliance period",
       "locator": "ceta-15500-target-clean-share-of-retail-load-2022-2025; PSE 2023 Biennial Clean Energy Implementation Plan Update; Chapter One, section 2 (Meeting our clean energy obligations)",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_target_share",
       "missing_reason": null,
       "note": "PSE maintains an interim target to serve at least 54.5 percent of retail electric load with clean energy resources over the 2022-2025 compliance period; the interim target is the average of the annual goals. The UTC denied PSE's petition to cut the 2024 and 2025 interim targets to 48 percent a year on 2024-11-07 and the docket closed 2024-11-08. PSE's own expression of the period target as a four-year average; the commission's approved interim targets are the annual series 43, 53, 59 and 63 percent (Final Order 08; Order 12 condition (1)(a)-(b)), which the compliance report of 2026-07-01 also restates. A utility's restatement does not replace the ordered figures.",
       "period": {
        "as_of": "2023-11-20",
        "end_year": 2025,
        "kind": "obligation_period",
        "label": "2022-2025",
        "start_year": 2022
       },
       "precision": 1,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "percent",
       "value": 54.5
      },
      "issuer": "Puget Sound Energy",
      "kind": "target",
      "locator": "Chapter One, section 2 (Meeting our clean energy obligations)",
      "method": "curated",
      "metric": "clean_share_of_retail_load",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "PSE maintains an interim target to serve at least 54.5 percent of retail electric load with clean energy resources over the 2022-2025 compliance period; the interim target is the average of the annual goals. The UTC denied PSE's petition to cut the 2024 and 2025 interim targets to 48 percent a year on 2024-11-07 and the docket closed 2024-11-08. PSE's own expression of the period target as a four-year average; the commission's approved interim targets are the annual series 43, 53, 59 and 63 percent (Final Order 08; Order 12 condition (1)(a)-(b)), which the compliance report of 2026-07-01 also restates. A utility's restatement does not replace the ordered figures.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2023-11-20",
       "end_year": 2025,
       "kind": "obligation_period",
       "label": "2022-2025",
       "start_year": 2022
      },
      "source_publisher": "Puget Sound Energy",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://www.pse.com/-/media/PDFs/CEIP/2023/001_BU23_Chapters_Final.pdf",
      "standing": "filed",
      "state": "WA",
      "statement": "interim target for the 2022-2025 compliance period",
      "unit": "percent",
      "value": 54.5
     },
     {
      "as_of": "2024-03-25",
      "assertion_id": "ceta-15500-target-annual-interim-2022",
      "basis": "of retail load served by renewable and nonemitting electric generation",
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-210795",
      "document": "Order 12 Approving CEIP Biennial Update Subject to Conditions",
      "evidence": "reported",
      "fact": {
       "basis": "of retail load served by renewable and nonemitting electric generation",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/ceta-15500-target-annual-interim-2022#policy_target_share",
       "label": "annual interim target approved by the commission",
       "locator": "ceta-15500-target-annual-interim-2022; Order 12 Approving CEIP Biennial Update Subject to Conditions; condition (1)(a); interim targets first approved in Final Order 08 paragraph 48",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_target_share",
       "missing_reason": null,
       "note": "\"PSE will maintain the Interim Targets approved by the Commission in Order 08 of Docket UE-210795 for the remainder of this compliance period (i.e., 2022 - 43 percent of retail load served by renewable and nonemitting electric generation; 2023 - 53 percent; 2024 - 59 percent; 2025 - 63 percent)\". Condition (1)(b) keeps one interim target per year; (1)(c) says unreasonably costly energy needed for 2025 will be considered at the compliance review.",
       "period": {
        "as_of": "2024-03-25",
        "end_year": 2022,
        "kind": "obligation_period",
        "label": "2022",
        "start_year": 2022
       },
       "precision": 1,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "percent",
       "value": 43.0
      },
      "issuer": "Washington Utilities and Transportation Commission",
      "kind": "target",
      "locator": "condition (1)(a); interim targets first approved in Final Order 08 paragraph 48",
      "method": "curated",
      "metric": "clean_share_of_retail_load",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "\"PSE will maintain the Interim Targets approved by the Commission in Order 08 of Docket UE-210795 for the remainder of this compliance period (i.e., 2022 - 43 percent of retail load served by renewable and nonemitting electric generation; 2023 - 53 percent; 2024 - 59 percent; 2025 - 63 percent)\". Condition (1)(b) keeps one interim target per year; (1)(c) says unreasonably costly energy needed for 2025 will be considered at the compliance review.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2024-03-25",
       "end_year": 2022,
       "kind": "obligation_period",
       "label": "2022",
       "start_year": 2022
      },
      "source_publisher": "Washington Utilities and Transportation Commission",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=1262&year=2021&docketNumber=210795",
      "standing": "ordered",
      "state": "WA",
      "statement": "annual interim target approved by the commission",
      "unit": "percent",
      "value": 43.0
     },
     {
      "as_of": "2024-03-25",
      "assertion_id": "ceta-15500-target-annual-interim-2023",
      "basis": "of retail load served by renewable and nonemitting electric generation",
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-210795",
      "document": "Order 12 Approving CEIP Biennial Update Subject to Conditions",
      "evidence": "reported",
      "fact": {
       "basis": "of retail load served by renewable and nonemitting electric generation",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/ceta-15500-target-annual-interim-2023#policy_target_share",
       "label": "annual interim target approved by the commission",
       "locator": "ceta-15500-target-annual-interim-2023; Order 12 Approving CEIP Biennial Update Subject to Conditions; condition (1)(a); interim targets first approved in Final Order 08 paragraph 48",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_target_share",
       "missing_reason": null,
       "note": "\"PSE will maintain the Interim Targets approved by the Commission in Order 08 of Docket UE-210795 for the remainder of this compliance period (i.e., 2022 - 43 percent of retail load served by renewable and nonemitting electric generation; 2023 - 53 percent; 2024 - 59 percent; 2025 - 63 percent)\". Condition (1)(b) keeps one interim target per year; (1)(c) says unreasonably costly energy needed for 2025 will be considered at the compliance review.",
       "period": {
        "as_of": "2024-03-25",
        "end_year": 2023,
        "kind": "obligation_period",
        "label": "2023",
        "start_year": 2023
       },
       "precision": 1,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "percent",
       "value": 53.0
      },
      "issuer": "Washington Utilities and Transportation Commission",
      "kind": "target",
      "locator": "condition (1)(a); interim targets first approved in Final Order 08 paragraph 48",
      "method": "curated",
      "metric": "clean_share_of_retail_load",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "\"PSE will maintain the Interim Targets approved by the Commission in Order 08 of Docket UE-210795 for the remainder of this compliance period (i.e., 2022 - 43 percent of retail load served by renewable and nonemitting electric generation; 2023 - 53 percent; 2024 - 59 percent; 2025 - 63 percent)\". Condition (1)(b) keeps one interim target per year; (1)(c) says unreasonably costly energy needed for 2025 will be considered at the compliance review.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2024-03-25",
       "end_year": 2023,
       "kind": "obligation_period",
       "label": "2023",
       "start_year": 2023
      },
      "source_publisher": "Washington Utilities and Transportation Commission",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=1262&year=2021&docketNumber=210795",
      "standing": "ordered",
      "state": "WA",
      "statement": "annual interim target approved by the commission",
      "unit": "percent",
      "value": 53.0
     },
     {
      "as_of": "2024-03-25",
      "assertion_id": "ceta-15500-target-annual-interim-2024",
      "basis": "of retail load served by renewable and nonemitting electric generation",
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-210795",
      "document": "Order 12 Approving CEIP Biennial Update Subject to Conditions",
      "evidence": "reported",
      "fact": {
       "basis": "of retail load served by renewable and nonemitting electric generation",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/ceta-15500-target-annual-interim-2024#policy_target_share",
       "label": "annual interim target approved by the commission",
       "locator": "ceta-15500-target-annual-interim-2024; Order 12 Approving CEIP Biennial Update Subject to Conditions; condition (1)(a); interim targets first approved in Final Order 08 paragraph 48",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_target_share",
       "missing_reason": null,
       "note": "\"PSE will maintain the Interim Targets approved by the Commission in Order 08 of Docket UE-210795 for the remainder of this compliance period (i.e., 2022 - 43 percent of retail load served by renewable and nonemitting electric generation; 2023 - 53 percent; 2024 - 59 percent; 2025 - 63 percent)\". Condition (1)(b) keeps one interim target per year; (1)(c) says unreasonably costly energy needed for 2025 will be considered at the compliance review.",
       "period": {
        "as_of": "2024-03-25",
        "end_year": 2024,
        "kind": "obligation_period",
        "label": "2024",
        "start_year": 2024
       },
       "precision": 1,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "percent",
       "value": 59.0
      },
      "issuer": "Washington Utilities and Transportation Commission",
      "kind": "target",
      "locator": "condition (1)(a); interim targets first approved in Final Order 08 paragraph 48",
      "method": "curated",
      "metric": "clean_share_of_retail_load",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "\"PSE will maintain the Interim Targets approved by the Commission in Order 08 of Docket UE-210795 for the remainder of this compliance period (i.e., 2022 - 43 percent of retail load served by renewable and nonemitting electric generation; 2023 - 53 percent; 2024 - 59 percent; 2025 - 63 percent)\". Condition (1)(b) keeps one interim target per year; (1)(c) says unreasonably costly energy needed for 2025 will be considered at the compliance review.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2024-03-25",
       "end_year": 2024,
       "kind": "obligation_period",
       "label": "2024",
       "start_year": 2024
      },
      "source_publisher": "Washington Utilities and Transportation Commission",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=1262&year=2021&docketNumber=210795",
      "standing": "ordered",
      "state": "WA",
      "statement": "annual interim target approved by the commission",
      "unit": "percent",
      "value": 59.0
     },
     {
      "as_of": "2024-09-27",
      "assertion_id": "ceta-15500-target-proposed-48-2024-2025",
      "basis": "of retail load served by renewable and nonemitting electric generation",
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-210795",
      "document": "Petition to amend Orders 08 and 12 (2024-09-27), as described in Order 14",
      "evidence": "reported",
      "fact": {
       "basis": "of retail load served by renewable and nonemitting electric generation",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/ceta-15500-target-proposed-48-2024-2025#policy_target_share",
       "label": "petition to lower the 2024 and 2025 annual interim targets",
       "locator": "ceta-15500-target-proposed-48-2024-2025; Petition to amend Orders 08 and 12 (2024-09-27), as described in Order 14; Order 14 paragraphs 3 and 18(1)",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_target_share",
       "missing_reason": null,
       "note": "Denied. Order 14 (2024-11-08): \"Puget Sound Energy's Petition filed September 27, 2024, is denied\"; the petition asked to lower the targets \"to 48 percent\" and asserted that without approval PSE would need \"a projected $200 million in short-term clean energy resources\".",
       "period": {
        "as_of": "2024-09-27",
        "end_year": 2025,
        "kind": "obligation_period",
        "label": "2024-2025",
        "start_year": 2024
       },
       "precision": 1,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "percent",
       "value": 48.0
      },
      "issuer": "Puget Sound Energy",
      "kind": "target",
      "locator": "Order 14 paragraphs 3 and 18(1)",
      "method": "curated",
      "metric": "clean_share_of_retail_load",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "Denied. Order 14 (2024-11-08): \"Puget Sound Energy's Petition filed September 27, 2024, is denied\"; the petition asked to lower the targets \"to 48 percent\" and asserted that without approval PSE would need \"a projected $200 million in short-term clean energy resources\".",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2024-09-27",
       "end_year": 2025,
       "kind": "obligation_period",
       "label": "2024-2025",
       "start_year": 2024
      },
      "source_publisher": "Washington Utilities and Transportation Commission",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=1377&year=2021&docketNumber=210795",
      "standing": "proposed",
      "state": "WA",
      "statement": "petition to lower the 2024 and 2025 annual interim targets",
      "unit": "percent",
      "value": 48.0
     },
     {
      "as_of": "2019-05-07",
      "assertion_id": "ceta-wa-target-coal-share-of-allocation-2025",
      "basis": "of the utility's allocation of electricity supplied by coal-fired resources",
      "curation": {
       "checked": "2026-09-18",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-4b4"
      },
      "docket": null,
      "document": "RCW 19.405.030 Coal-fired resources - Depreciation schedule - Penalties",
      "evidence": "reported",
      "fact": {
       "basis": "of the utility's allocation of electricity supplied by coal-fired resources",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/ceta-wa-target-coal-share-of-allocation-2025#policy_target_share",
       "label": "eliminate coal-fired resources from the utility's allocation of electricity",
       "locator": "ceta-wa-target-coal-share-of-allocation-2025; RCW 19.405.030 Coal-fired resources - Depreciation schedule - Penalties",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_target_share",
       "missing_reason": null,
       "note": "On or before December 31, 2025. Excludes decommissioning and remediation costs; long-term BPA purchases are exempt unless the electricity is known to be coal-fired. The commission must set depreciation schedules ending no later than 2025-12-31.",
       "period": {
        "as_of": "2019-05-07",
        "end_year": 2025,
        "kind": "obligation_period",
        "label": "2025",
        "start_year": 2025
       },
       "precision": 1,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "percent",
       "value": 0.0
      },
      "issuer": "Washington State Legislature",
      "kind": "target",
      "locator": null,
      "method": "curated",
      "metric": "coal_share_of_allocation",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "On or before December 31, 2025. Excludes decommissioning and remediation costs; long-term BPA purchases are exempt unless the electricity is known to be coal-fired. The commission must set depreciation schedules ending no later than 2025-12-31.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2019-05-07",
       "end_year": 2025,
       "kind": "obligation_period",
       "label": "2025",
       "start_year": 2025
      },
      "source_publisher": "Washington State Legislature",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://app.leg.wa.gov/RCW/default.aspx?cite=19.405.030",
      "standing": "enacted",
      "state": "WA",
      "statement": "eliminate coal-fired resources from the utility's allocation of electricity",
      "unit": "percent",
      "value": 0.0
     },
     {
      "as_of": "2023-11-20",
      "assertion_id": "ceta-15500-target-clean-share-of-retail-load-2025",
      "basis": "of retail electric load",
      "curation": {
       "checked": "2026-09-18",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-4b4"
      },
      "docket": "UE-210795",
      "document": "PSE 2023 Biennial Clean Energy Implementation Plan Update",
      "evidence": "reported",
      "fact": {
       "basis": "of retail electric load",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/ceta-15500-target-clean-share-of-retail-load-2025#policy_target_share",
       "label": "annual clean energy goal for 2025",
       "locator": "ceta-15500-target-clean-share-of-retail-load-2025; PSE 2023 Biennial Clean Energy Implementation Plan Update; Chapter One, section 2 (Meeting our clean energy obligations)",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_target_share",
       "missing_reason": null,
       "note": "PSE sought to adjust the 2025 annual goal from 63 percent to 60 percent while keeping the 54.5 percent four-year interim target, citing supply constraints and a tightening market for clean energy resources. Not adopted: Order 12 (2024-03-25) condition (1)(a) kept the 2025 interim target at 63 percent.",
       "period": {
        "as_of": "2023-11-20",
        "end_year": 2025,
        "kind": "obligation_period",
        "label": "2025",
        "start_year": 2025
       },
       "precision": 1,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "percent",
       "value": 60.0
      },
      "issuer": "Puget Sound Energy",
      "kind": "target",
      "locator": "Chapter One, section 2 (Meeting our clean energy obligations)",
      "method": "curated",
      "metric": "clean_share_of_retail_load",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "PSE sought to adjust the 2025 annual goal from 63 percent to 60 percent while keeping the 54.5 percent four-year interim target, citing supply constraints and a tightening market for clean energy resources. Not adopted: Order 12 (2024-03-25) condition (1)(a) kept the 2025 interim target at 63 percent.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2023-11-20",
       "end_year": 2025,
       "kind": "obligation_period",
       "label": "2025",
       "start_year": 2025
      },
      "source_publisher": "Puget Sound Energy",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://www.pse.com/-/media/PDFs/CEIP/2023/001_BU23_Chapters_Final.pdf",
      "standing": "proposed",
      "state": "WA",
      "statement": "annual clean energy goal for 2025",
      "unit": "percent",
      "value": 60.0
     },
     {
      "as_of": "2024-03-25",
      "assertion_id": "ceta-15500-target-annual-interim-2025",
      "basis": "of retail load served by renewable and nonemitting electric generation",
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-210795",
      "document": "Order 12 Approving CEIP Biennial Update Subject to Conditions",
      "evidence": "reported",
      "fact": {
       "basis": "of retail load served by renewable and nonemitting electric generation",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/ceta-15500-target-annual-interim-2025#policy_target_share",
       "label": "annual interim target approved by the commission",
       "locator": "ceta-15500-target-annual-interim-2025; Order 12 Approving CEIP Biennial Update Subject to Conditions; condition (1)(a); interim targets first approved in Final Order 08 paragraph 48",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_target_share",
       "missing_reason": null,
       "note": "\"PSE will maintain the Interim Targets approved by the Commission in Order 08 of Docket UE-210795 for the remainder of this compliance period (i.e., 2022 - 43 percent of retail load served by renewable and nonemitting electric generation; 2023 - 53 percent; 2024 - 59 percent; 2025 - 63 percent)\". Condition (1)(b) keeps one interim target per year; (1)(c) says unreasonably costly energy needed for 2025 will be considered at the compliance review.",
       "period": {
        "as_of": "2024-03-25",
        "end_year": 2025,
        "kind": "obligation_period",
        "label": "2025",
        "start_year": 2025
       },
       "precision": 1,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "percent",
       "value": 63.0
      },
      "issuer": "Washington Utilities and Transportation Commission",
      "kind": "target",
      "locator": "condition (1)(a); interim targets first approved in Final Order 08 paragraph 48",
      "method": "curated",
      "metric": "clean_share_of_retail_load",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "\"PSE will maintain the Interim Targets approved by the Commission in Order 08 of Docket UE-210795 for the remainder of this compliance period (i.e., 2022 - 43 percent of retail load served by renewable and nonemitting electric generation; 2023 - 53 percent; 2024 - 59 percent; 2025 - 63 percent)\". Condition (1)(b) keeps one interim target per year; (1)(c) says unreasonably costly energy needed for 2025 will be considered at the compliance review.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2024-03-25",
       "end_year": 2025,
       "kind": "obligation_period",
       "label": "2025",
       "start_year": 2025
      },
      "source_publisher": "Washington Utilities and Transportation Commission",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=1262&year=2021&docketNumber=210795",
      "standing": "ordered",
      "state": "WA",
      "statement": "annual interim target approved by the commission",
      "unit": "percent",
      "value": 63.0
     },
     {
      "as_of": "2024-07-11",
      "assertion_id": "ceta-15500-target-clean-share-of-retail-load-2026-2029",
      "basis": null,
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-210795",
      "document": "Order 13 Granting Petition to Amend Orders 8 and 12",
      "evidence": "reported",
      "fact": {
       "basis": "A target as the statute, order or filing states it, in percent or fraction of the load or sales basis named on the fact; standing on the item says whether it is enacted, ordered, filed, proposed or compiled",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/ceta-15500-target-clean-share-of-retail-load-2026-2029#policy_target_share",
       "label": "interim targets for the 2026-2029 compliance period",
       "locator": "ceta-15500-target-clean-share-of-retail-load-2026-2029; Order 13 Granting Petition to Amend Orders 8 and 12; paragraph 10",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_target_share",
       "missing_reason": "not_yet_filed",
       "note": "No 2026-2029 interim targets exist for PSE. Order 13: \"PSE is no longer required to file a 2025 CEIP, subject to the conditions described in Dockets UG-240434 and UE-240433\"; the clean energy implementation plan, integrated resource plans and public participation plan are consolidated into \"a single Integrated System Plan, to be filed in 2027 pursuant to the outcome of Docket U-240281\" (ESHB 1589). The policy research of 2026-09-18 recorded the 2025 CEIP docket as not found; this order is why.",
       "period": {
        "as_of": "2024-07-11",
        "end_year": 2029,
        "kind": "obligation_period",
        "label": "2026-2029",
        "start_year": 2026
       },
       "precision": 1,
       "quality": "missing",
       "source_ref": "clean-energy-obligations",
       "unit": "percent",
       "value": null
      },
      "issuer": "Washington Utilities and Transportation Commission",
      "kind": "target",
      "locator": "paragraph 10",
      "method": "curated",
      "metric": "clean_share_of_retail_load",
      "missing_reason": "not_yet_filed",
      "next_step": null,
      "next_step_date": null,
      "note": "No 2026-2029 interim targets exist for PSE. Order 13: \"PSE is no longer required to file a 2025 CEIP, subject to the conditions described in Dockets UG-240434 and UE-240433\"; the clean energy implementation plan, integrated resource plans and public participation plan are consolidated into \"a single Integrated System Plan, to be filed in 2027 pursuant to the outcome of Docket U-240281\" (ESHB 1589). The policy research of 2026-09-18 recorded the 2025 CEIP docket as not found; this order is why.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2024-07-11",
       "end_year": 2029,
       "kind": "obligation_period",
       "label": "2026-2029",
       "start_year": 2026
      },
      "source_publisher": "Washington Utilities and Transportation Commission",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=1309&year=2021&docketNumber=210795",
      "standing": null,
      "state": "WA",
      "statement": "interim targets for the 2026-2029 compliance period",
      "unit": "percent",
      "value": null
     },
     {
      "as_of": "2019-05-07",
      "assertion_id": "ceta-wa-target-clean-share-of-retail-sales-2030",
      "basis": "of retail sales of electricity to Washington retail electric customers",
      "curation": {
       "checked": "2026-09-18",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-4b4"
      },
      "docket": null,
      "document": "RCW 19.405.040 Greenhouse gas neutral electricity supply",
      "evidence": "reported",
      "fact": {
       "basis": "of retail sales of electricity to Washington retail electric customers",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/ceta-wa-target-clean-share-of-retail-sales-2030#policy_target_share",
       "label": "greenhouse gas neutral retail sales, at least 80 percent from renewable and nonemitting resources",
       "locator": "ceta-wa-target-clean-share-of-retail-sales-2030; RCW 19.405.040 Greenhouse gas neutral electricity supply",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_target_share",
       "missing_reason": null,
       "note": "By January 1, 2030. Up to 20 percent of the obligation may be met by alternative compliance: alternative compliance payments, unbundled renewable energy credits or energy transformation projects. Four-year compliance periods 2030-2033, 2034-2037, 2038-2041 and 2042-2044.",
       "period": {
        "as_of": "2019-05-07",
        "end_year": 2030,
        "kind": "obligation_period",
        "label": "2030",
        "start_year": 2030
       },
       "precision": 1,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "percent",
       "value": 80.0
      },
      "issuer": "Washington State Legislature",
      "kind": "target",
      "locator": null,
      "method": "curated",
      "metric": "clean_share_of_retail_sales",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "By January 1, 2030. Up to 20 percent of the obligation may be met by alternative compliance: alternative compliance payments, unbundled renewable energy credits or energy transformation projects. Four-year compliance periods 2030-2033, 2034-2037, 2038-2041 and 2042-2044.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2019-05-07",
       "end_year": 2030,
       "kind": "obligation_period",
       "label": "2030",
       "start_year": 2030
      },
      "source_publisher": "Washington State Legislature",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://app.leg.wa.gov/RCW/default.aspx?cite=19.405.040",
      "standing": "enacted",
      "state": "WA",
      "statement": "greenhouse gas neutral retail sales, at least 80 percent from renewable and nonemitting resources",
      "unit": "percent",
      "value": 80.0
     },
     {
      "as_of": "2019-05-07",
      "assertion_id": "ceta-wa-target-clean-share-of-retail-sales-2045",
      "basis": "of retail sales of electricity to Washington retail electric customers",
      "curation": {
       "checked": "2026-09-18",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-4b4"
      },
      "docket": null,
      "document": "RCW 19.405.050 One hundred percent renewable and nonemitting electricity supply",
      "evidence": "reported",
      "fact": {
       "basis": "of retail sales of electricity to Washington retail electric customers",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/ceta-wa-target-clean-share-of-retail-sales-2045#policy_target_share",
       "label": "nonemitting generation and renewable resources supply 100 percent of retail sales",
       "locator": "ceta-wa-target-clean-share-of-retail-sales-2045; RCW 19.405.050 One hundred percent renewable and nonemitting electricity supply",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_target_share",
       "missing_reason": null,
       "note": "By January 1, 2045, with an annual demonstration of compliance after that date.",
       "period": {
        "as_of": "2019-05-07",
        "end_year": 2045,
        "kind": "obligation_period",
        "label": "2045",
        "start_year": 2045
       },
       "precision": 1,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "percent",
       "value": 100.0
      },
      "issuer": "Washington State Legislature",
      "kind": "target",
      "locator": null,
      "method": "curated",
      "metric": "clean_share_of_retail_sales",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "By January 1, 2045, with an annual demonstration of compliance after that date.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2019-05-07",
       "end_year": 2045,
       "kind": "obligation_period",
       "label": "2045",
       "start_year": 2045
      },
      "source_publisher": "Washington State Legislature",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://app.leg.wa.gov/RCW/default.aspx?cite=19.405.050",
      "standing": "enacted",
      "state": "WA",
      "statement": "nonemitting generation and renewable resources supply 100 percent of retail sales",
      "unit": "percent",
      "value": 100.0
     }
    ],
    "uncertainties": [
     {
      "anchor": "docs/research/2026-09-18-policy-sources.md#3-bodies-and-decisions-43",
      "id": "utc-endpoint",
      "resolution": "The document endpoint served every filing read on 2026-09-19 and 2026-09-21; it remains undocumented.",
      "status": "resolved",
      "text": "No documented JSON API; the `apiproxy` host answered HTTP 500.30 all session and detail pages said \"Record not found\"."
     },
     {
      "anchor": "docs/research/2026-09-18-policy-sources.md#3-bodies-and-decisions-43",
      "id": "utc-pre-2024",
      "resolution": null,
      "status": "open",
      "text": "Docket files before 2024 are not available. We are working to resolve the issue."
     },
     {
      "anchor": "docs/research/2026-09-18-policy-sources.md#22-ceip-filings--investor-owned-utc",
      "id": "ceip-pdf",
      "resolution": null,
      "status": "open",
      "text": "All PDF; targets need hand transcription."
     },
     {
      "anchor": "docs/research/2026-09-18-policy-sources.md#21-obligations-statute-text",
      "id": "utc-wac",
      "resolution": null,
      "status": "open",
      "text": "WAC 480-100-600 through -665 (CEIP content, biennial updates -640(11), public participation -655): snapshot; WAC not fetched."
     },
     {
      "anchor": "docs/research/2026-09-18-policy-sources.md#22-ceip-filings--investor-owned-utc",
      "id": "pse-2025-ceip",
      "resolution": "Order 13 in UE-210795 (2024-07-11): PSE is no longer required to file a 2025 CEIP; planning is consolidated into a 2027 Integrated System Plan.",
      "status": "resolved",
      "text": "2025 CEIP docket not found by search (unverified)."
     }
    ]
   },
   {
    "applicability": {
     "as_of": "2006-11-07",
     "assertion_id": "eia-15500-applicability",
     "basis": null,
     "curation": {
      "checked": "2026-09-21",
      "review_after": "2027-07-01",
      "review_due": false,
      "reviewer": "claude-w14"
     },
     "docket": null,
     "document": "RCW 19.285.030 Definitions",
     "evidence": "reported",
     "fact": null,
     "issuer": "Washington State Legislature",
     "kind": "applicability",
     "locator": "(19)",
     "method": "curated",
     "metric": null,
     "missing_reason": null,
     "next_step": null,
     "next_step_date": null,
     "note": "\"'Qualifying utility' means an electric utility, as the term 'electric utility' is defined in RCW 19.29A.010, that serves more than 25,000 customers in the state of Washington. The number of customers served may be based on data reported by a utility in form 861\". Initiative 937 (2007 c 1), approved 2006-11-07; section last amended 2024 c 278. Commerce's 2026 report summary lists Puget Sound Energy among the 18 qualifying utilities; its EIA-861 customer count is on the retail block of this page.",
     "participation_url": null,
     "percent_decimals": null,
     "period": {
      "as_of": "2006-11-07",
      "kind": "instant",
      "label": "2006-11-07"
     },
     "source_publisher": "Washington State Legislature",
     "source_ref": "clean-energy-obligations",
     "source_url": "https://app.leg.wa.gov/RCW/default.aspx?cite=19.285.030",
     "standing": "enacted",
     "state": "WA",
     "statement": "qualifying utility under the Energy Independence Act: an electric utility serving more than 25,000 customers in Washington",
     "unit": null,
     "value": null
    },
    "applicability_all": [
     {
      "as_of": "2006-11-07",
      "assertion_id": "eia-15500-applicability",
      "basis": null,
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": null,
      "document": "RCW 19.285.030 Definitions",
      "evidence": "reported",
      "fact": null,
      "issuer": "Washington State Legislature",
      "kind": "applicability",
      "locator": "(19)",
      "method": "curated",
      "metric": null,
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "\"'Qualifying utility' means an electric utility, as the term 'electric utility' is defined in RCW 19.29A.010, that serves more than 25,000 customers in the state of Washington. The number of customers served may be based on data reported by a utility in form 861\". Initiative 937 (2007 c 1), approved 2006-11-07; section last amended 2024 c 278. Commerce's 2026 report summary lists Puget Sound Energy among the 18 qualifying utilities; its EIA-861 customer count is on the retail block of this page.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2006-11-07",
       "kind": "instant",
       "label": "2006-11-07"
      },
      "source_publisher": "Washington State Legislature",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://app.leg.wa.gov/RCW/default.aspx?cite=19.285.030",
      "standing": "enacted",
      "state": "WA",
      "statement": "qualifying utility under the Energy Independence Act: an electric utility serving more than 25,000 customers in Washington",
      "unit": null,
      "value": null
     }
    ],
    "applicability_rows": 1,
    "comparisons": [
     {
      "aggregate": "state-WA",
      "id": "wa-eia-conservation-2024-2025",
      "title": "Energy Independence Act conservation, 2024–2025"
     }
    ],
    "deciding_events": [
     {
      "as_of": "2026-01-14",
      "assertion_id": "eia-15500-event-250834-open",
      "basis": null,
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-06-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-250834",
      "document": "Docket UE-250834 page (status Pending; filed 2025-10-31; Order 01 of 2026-01-14)",
      "evidence": "reported",
      "fact": null,
      "issuer": "Washington Utilities and Transportation Commission",
      "kind": "deciding_event",
      "locator": "docket page",
      "method": "curated",
      "metric": null,
      "missing_reason": null,
      "next_step": "2026-2027 biennial conservation report and commission review; no date scheduled on the docket page",
      "next_step_date": null,
      "note": "Status Pending on 2026-09-21 with no scheduled event after Order 01. The 2024-2025 cycle in UE-230892 ran: report filed 2026-06-01, notice of written comments 2026-06-22, staff comments 2026-07-31, Order 02 2026-09-10. No renewable-target (RPS) docket for 2026 was found for PSE.",
      "participation_url": "https://www.utc.wa.gov/consumers/submit-comment",
      "percent_decimals": null,
      "period": {
       "as_of": "2026-01-14",
       "end_year": 2027,
       "kind": "obligation_period",
       "label": "2026-2027",
       "start_year": 2026
      },
      "source_publisher": "Washington Utilities and Transportation Commission",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://www.utc.wa.gov/casedocket/2025/250834",
      "standing": "open",
      "state": "WA",
      "statement": "PSE's electric biennial conservation plan for 2026-2027: docket pending; the 2026-2027 biennial conservation report will be reviewed here",
      "unit": null,
      "value": null
     }
    ],
    "determinations": [
     {
      "as_of": "2024-01-17",
      "assertion_id": "eia-15500-determination-order-01-230892",
      "basis": null,
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-230892",
      "document": "Order 01 Accepting 2024-2033 Ten-Year Achievable Conservation Potential and 2024-2025 Biennial Conservation Target, Subject to Conditions",
      "evidence": "reported",
      "fact": null,
      "issuer": "Washington Utilities and Transportation Commission",
      "kind": "determination",
      "locator": "findings (6)-(11)",
      "method": "curated",
      "metric": null,
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "Accepts a ten-year achievable potential of 1,521,999 MWh, an EIA target of 304,400 MWh, an EIA penalty threshold of 268,702 MWh and a decoupling penalty threshold of 15,220 MWh. Effective 2024-01-17.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2024-01-17",
       "end_year": 2025,
       "kind": "obligation_period",
       "label": "2024-2025",
       "start_year": 2024
      },
      "source_publisher": "Washington Utilities and Transportation Commission",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=28&year=2023&docketNumber=230892",
      "standing": "ordered",
      "state": "WA",
      "statement": "order accepting the ten-year conservation potential and the 2024-2025 biennial conservation target, subject to conditions",
      "unit": null,
      "value": null
     },
     {
      "as_of": "2026-01-14",
      "assertion_id": "eia-15500-determination-order-01-250834",
      "basis": null,
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2028-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-250834",
      "document": "Order 01 Accepting 2026-2035 Ten-Year Achievable Conservation Potential and 2026-2027 Biennial Conservation Target, Subject to Conditions",
      "evidence": "reported",
      "fact": null,
      "issuer": "Washington Utilities and Transportation Commission",
      "kind": "determination",
      "locator": "findings (6)-(10)",
      "method": "curated",
      "metric": null,
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "Accepts a ten-year achievable potential of 966,140 MWh, an EIA target of 193,228 MWh, an EIA penalty threshold of 156,781 MWh and a decoupling penalty threshold of 9,661 MWh, \"pursuant to Order 7 in Docket UE-121697, subject to the conditions\" of the order.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2026-01-14",
       "end_year": 2027,
       "kind": "obligation_period",
       "label": "2026-2027",
       "start_year": 2026
      },
      "source_publisher": "Washington Utilities and Transportation Commission",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=37&year=2025&docketNumber=250834",
      "standing": "ordered",
      "state": "WA",
      "statement": "order accepting the 2026-2035 ten-year conservation potential and the 2026-2027 biennial conservation target, subject to conditions",
      "unit": null,
      "value": null
     },
     {
      "as_of": "2026-09-10",
      "assertion_id": "eia-15500-determination-order-02-230892",
      "basis": null,
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-230892",
      "document": "Order 02 Accepting Puget Sound Energy's 2024-2025 Biennial Conservation Report",
      "evidence": "reported",
      "fact": null,
      "issuer": "Washington Utilities and Transportation Commission",
      "kind": "determination",
      "locator": "Table 1; findings (3)-(4); paragraph 21(1)",
      "method": "curated",
      "metric": null,
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "\"PSE overachieved both its EIA target of 304,400 MWh and its EIA Penalty Threshold of 268,702 MWh, achieving 519,873 MWh of EIA Penalty-Liable Achievement\"; \"PSE is in compliance with its biennial conservation targets accepted in Order 01, WAC 480-109-120, and RCW\" 19.285.040; \"PSE achieved 235,951 MWh in excess conservation savings that may be used to mitigate shortfalls in the subsequent two biennial targets\". Effective 2026-09-10.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2026-09-10",
       "end_year": 2025,
       "kind": "obligation_period",
       "label": "2024-2025",
       "start_year": 2024
      },
      "source_publisher": "Washington Utilities and Transportation Commission",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=104&year=2023&docketNumber=230892",
      "standing": "ordered",
      "state": "WA",
      "statement": "order accepting the 2024-2025 biennial conservation report: PSE in compliance with its biennial conservation targets",
      "unit": null,
      "value": null
     },
     {
      "as_of": "2026-09-21",
      "assertion_id": "eia-15500-determination-renewable-2026",
      "basis": null,
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": null,
      "document": "UTC docket search, company Puget Sound Energy, keyword Renewable Portfolio Standard",
      "evidence": "reported",
      "fact": null,
      "issuer": "Washington Utilities and Transportation Commission",
      "kind": "determination",
      "locator": "newest matching docket UE-250401 (2025 Annual Renewable Portfolio Standard Report), closed 2025-08-08, no order listed",
      "method": "curated",
      "metric": null,
      "missing_reason": "no_source",
      "next_step": null,
      "next_step_date": null,
      "note": "No 2026 renewable portfolio standard docket found for PSE on 2026-09-21; Avista (UE-260468) and PacifiCorp (UE-260464) 2025 reports closed 2026-08-13. Commerce's page says that after 2026-06-12 utilities move from annual to biennial EIA reporting (HB 2575). The 15 percent figure in the Commerce summary is a compilation, not a commission finding.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2026-09-21",
       "end_year": 2026,
       "kind": "obligation_period",
       "label": "2026",
       "start_year": 2026
      },
      "source_publisher": "Washington Utilities and Transportation Commission",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://www.utc.wa.gov/documents-and-proceedings/dockets?combine=Renewable+Portfolio+Standard&keys=&company_name=Puget+Sound+Energy&industry=All&field_docket_case_status_target_id=All",
      "standing": null,
      "state": "WA",
      "statement": "commission finding on PSE's 2026 renewable energy target",
      "unit": null,
      "value": null
     }
    ],
    "filed_achievements": [
     {
      "as_of": "2026-06-01",
      "assertion_id": "eia-15500-filed-conservation-mwh-2024-2025",
      "basis": "total verified conservation savings, all programs",
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-230892",
      "document": "2024-2025 Biennial Conservation Report for Electric and Natural Gas Programs",
      "evidence": "reported",
      "fact": {
       "basis": "total verified conservation savings, all programs",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/eia-15500-filed-conservation-mwh-2024-2025#policy_filed_mwh",
       "label": "verified electric conservation savings over the biennium, as reported by the utility",
       "locator": "eia-15500-filed-conservation-mwh-2024-2025; 2024-2025 Biennial Conservation Report for Electric and Natural Gas Programs; Executive Summary, Table 0-1",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_filed_mwh",
       "missing_reason": null,
       "note": "Table 0-1: total conservation savings 574,489 MWh against a 408,065 MWh goal; \"Total Verified Penalty Threshold Savings\" 519,873 MWh against the 283,922 MWh combined threshold (268,702 EIA plus 15,220 decoupling). Report filed 2026-06-01 under WAC 480-109-120(4).",
       "period": {
        "as_of": "2026-06-01",
        "end_year": 2025,
        "kind": "obligation_period",
        "label": "2024-2025",
        "start_year": 2024
       },
       "precision": 0,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "MWh",
       "value": 574489.0
      },
      "issuer": "Puget Sound Energy",
      "kind": "filed_achievement",
      "locator": "Executive Summary, Table 0-1",
      "method": "curated",
      "metric": "conservation_mwh",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "Table 0-1: total conservation savings 574,489 MWh against a 408,065 MWh goal; \"Total Verified Penalty Threshold Savings\" 519,873 MWh against the 283,922 MWh combined threshold (268,702 EIA plus 15,220 decoupling). Report filed 2026-06-01 under WAC 480-109-120(4).",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2026-06-01",
       "end_year": 2025,
       "kind": "obligation_period",
       "label": "2024-2025",
       "start_year": 2024
      },
      "source_publisher": "Puget Sound Energy",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=90&year=2023&docketNumber=230892",
      "standing": "filed",
      "state": "WA",
      "statement": "verified electric conservation savings over the biennium, as reported by the utility",
      "unit": "MWh",
      "value": 574489.0
     },
     {
      "as_of": "2026-06-01",
      "assertion_id": "eia-15500-filed-conservation-penalty-liable-mwh-2024-2025",
      "basis": "savings from programs that count toward the EIA and decoupling penalty thresholds",
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-230892",
      "document": "2024-2025 Biennial Conservation Report for Electric and Natural Gas Programs",
      "evidence": "reported",
      "fact": {
       "basis": "savings from programs that count toward the EIA and decoupling penalty thresholds",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/eia-15500-filed-conservation-penalty-liable-mwh-2024-2025#policy_filed_mwh",
       "label": "verified penalty-liable conservation savings over the biennium, as reported by the utility",
       "locator": "eia-15500-filed-conservation-penalty-liable-mwh-2024-2025; 2024-2025 Biennial Conservation Report for Electric and Natural Gas Programs; Executive Summary, Table 0-1; Section II.G",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_filed_mwh",
       "missing_reason": null,
       "note": "Excess over the combined threshold: 235,951 MWh.",
       "period": {
        "as_of": "2026-06-01",
        "end_year": 2025,
        "kind": "obligation_period",
        "label": "2024-2025",
        "start_year": 2024
       },
       "precision": 0,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "MWh",
       "value": 519873.0
      },
      "issuer": "Puget Sound Energy",
      "kind": "filed_achievement",
      "locator": "Executive Summary, Table 0-1; Section II.G",
      "method": "curated",
      "metric": "conservation_mwh",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "Excess over the combined threshold: 235,951 MWh.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2026-06-01",
       "end_year": 2025,
       "kind": "obligation_period",
       "label": "2024-2025",
       "start_year": 2024
      },
      "source_publisher": "Puget Sound Energy",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=90&year=2023&docketNumber=230892",
      "standing": "filed",
      "state": "WA",
      "statement": "verified penalty-liable conservation savings over the biennium, as reported by the utility",
      "unit": "MWh",
      "value": 519873.0
     },
     {
      "as_of": "2026-06-01",
      "assertion_id": "eia-15500-filed_achievement-conservation-mwh-2024",
      "basis": null,
      "curation": {
       "checked": "2026-09-27",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w55"
      },
      "docket": null,
      "document": "EIA 2026 Report Summary and Detail.xlsx, sheet Conservation by Utility",
      "evidence": "reported",
      "fact": {
       "basis": "What the utility itself reported for the period in MWh; the utility's account, not the issuing body's finding",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/eia-15500-filed_achievement-conservation-mwh-2024#policy_filed_mwh",
       "label": "conservation acquired in 2024",
       "locator": "eia-15500-filed_achievement-conservation-mwh-2024; EIA 2026 Report Summary and Detail.xlsx, sheet Conservation by Utility; cell C17",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_filed_mwh",
       "missing_reason": null,
       "note": "Counts toward the 2024-2025 biennial target.",
       "period": {
        "as_of": "2026-06-01",
        "end_year": 2024,
        "kind": "obligation_period",
        "label": "2024",
        "start_year": 2024
       },
       "precision": 0,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "MWh",
       "value": 280964.0
      },
      "issuer": "Washington State Department of Commerce",
      "kind": "filed_achievement",
      "locator": "cell C17",
      "method": "curated",
      "metric": "conservation_mwh",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "Counts toward the 2024-2025 biennial target.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2026-06-01",
       "end_year": 2024,
       "kind": "obligation_period",
       "label": "2024",
       "start_year": 2024
      },
      "source_publisher": "Washington State Department of Commerce",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://deptofcommerce.app.box.com/index.php?rm=box_download_shared_file&shared_name=y27oz4btzu41qjzorjijhy44xquuoa1u&file_id=f_2394988863865",
      "standing": "compiled",
      "state": "WA",
      "statement": "conservation acquired in 2024",
      "unit": "MWh",
      "value": 280964.0
     },
     {
      "as_of": "2026-06-01",
      "assertion_id": "eia-15500-filed_achievement-conservation-share-of-retail-load-2024-2025",
      "basis": "of retail load over the biennial period's two load years (Commerce's sheet Select Data)",
      "curation": {
       "checked": "2026-09-27",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w55"
      },
      "docket": null,
      "document": "EIA 2026 Report Summary and Detail.xlsx, sheet Conservation by Utility",
      "evidence": "reported",
      "fact": {
       "basis": "of retail load over the biennial period's two load years (Commerce's sheet Select Data)",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/eia-15500-filed_achievement-conservation-share-of-retail-load-2024-2025#policy_filed_share",
       "label": "2024-2025 conservation acquired as a share of retail load, as Commerce computed it",
       "locator": "eia-15500-filed_achievement-conservation-share-of-retail-load-2024-2025; EIA 2026 Report Summary and Detail.xlsx, sheet Conservation by Utility; cell G17",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_filed_share",
       "missing_reason": null,
       "note": "Commerce's column G formula, (2024 acquired + 2025 acquired) / the biennial period's two load years on sheet Select Data (columns C and D); the cell's value, not recomputed. Commerce formats it as a percent to one decimal.",
       "period": {
        "as_of": "2026-06-01",
        "end_year": 2025,
        "kind": "obligation_period",
        "label": "2024-2025",
        "start_year": 2024
       },
       "precision": 6,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "fraction",
       "value": 0.013563
      },
      "issuer": "Washington State Department of Commerce",
      "kind": "filed_achievement",
      "locator": "cell G17",
      "method": "curated",
      "metric": "conservation_share_of_retail_load",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "Commerce's column G formula, (2024 acquired + 2025 acquired) / the biennial period's two load years on sheet Select Data (columns C and D); the cell's value, not recomputed. Commerce formats it as a percent to one decimal.",
      "participation_url": null,
      "percent_decimals": 1,
      "period": {
       "as_of": "2026-06-01",
       "end_year": 2025,
       "kind": "obligation_period",
       "label": "2024-2025",
       "start_year": 2024
      },
      "source_publisher": "Washington State Department of Commerce",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://deptofcommerce.app.box.com/index.php?rm=box_download_shared_file&shared_name=y27oz4btzu41qjzorjijhy44xquuoa1u&file_id=f_2394988863865",
      "standing": "compiled",
      "state": "WA",
      "statement": "2024-2025 conservation acquired as a share of retail load, as Commerce computed it",
      "unit": "fraction",
      "value": 0.013563
     },
     {
      "as_of": "2026-06-01",
      "assertion_id": "eia-15500-filed_achievement-conservation-share-of-target-2024-2025",
      "basis": "of the 2024-2025 conservation target in Commerce's column B",
      "curation": {
       "checked": "2026-09-27",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w55"
      },
      "docket": null,
      "document": "EIA 2026 Report Summary and Detail.xlsx, sheet Conservation by Utility",
      "evidence": "reported",
      "fact": {
       "basis": "of the 2024-2025 conservation target in Commerce's column B",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/eia-15500-filed_achievement-conservation-share-of-target-2024-2025#policy_filed_share",
       "label": "total conservation savings as a share of the 2024-2025 target, as Commerce computed it",
       "locator": "eia-15500-filed_achievement-conservation-share-of-target-2024-2025; EIA 2026 Report Summary and Detail.xlsx, sheet Conservation by Utility; cell F17",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_filed_share",
       "missing_reason": null,
       "note": "Commerce's column F formula, (2024 acquired + 2025 acquired + excess from the prior two bienniums) / 2024-2025 target; the cell's value, not recomputed. Commerce formats it as a whole percent.",
       "period": {
        "as_of": "2026-06-01",
        "end_year": 2025,
        "kind": "obligation_period",
        "label": "2024-2025",
        "start_year": 2024
       },
       "precision": 6,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "fraction",
       "value": 2.138023
      },
      "issuer": "Washington State Department of Commerce",
      "kind": "filed_achievement",
      "locator": "cell F17",
      "method": "curated",
      "metric": "conservation_share_of_target",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "Commerce's column F formula, (2024 acquired + 2025 acquired + excess from the prior two bienniums) / 2024-2025 target; the cell's value, not recomputed. Commerce formats it as a whole percent.",
      "participation_url": null,
      "percent_decimals": 0,
      "period": {
       "as_of": "2026-06-01",
       "end_year": 2025,
       "kind": "obligation_period",
       "label": "2024-2025",
       "start_year": 2024
      },
      "source_publisher": "Washington State Department of Commerce",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://deptofcommerce.app.box.com/index.php?rm=box_download_shared_file&shared_name=y27oz4btzu41qjzorjijhy44xquuoa1u&file_id=f_2394988863865",
      "standing": "compiled",
      "state": "WA",
      "statement": "total conservation savings as a share of the 2024-2025 target, as Commerce computed it",
      "unit": "fraction",
      "value": 2.138023
     },
     {
      "as_of": "2026-06-01",
      "assertion_id": "eia-15500-filed_achievement-excess-conservation-mwh-2024-2025",
      "basis": null,
      "curation": {
       "checked": "2026-09-27",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w55"
      },
      "docket": null,
      "document": "EIA 2026 Report Summary and Detail.xlsx, sheet Conservation by Utility",
      "evidence": "reported",
      "fact": {
       "basis": "What the utility itself reported for the period in MWh; the utility's account, not the issuing body's finding",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/eia-15500-filed_achievement-excess-conservation-mwh-2024-2025#policy_filed_mwh",
       "label": "excess conservation carried from the prior two bienniums toward the 2024-2025 target",
       "locator": "eia-15500-filed_achievement-excess-conservation-mwh-2024-2025; EIA 2026 Report Summary and Detail.xlsx, sheet Conservation by Utility; cell E17",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_filed_mwh",
       "missing_reason": null,
       "note": "Commerce's column E.",
       "period": {
        "as_of": "2026-06-01",
        "end_year": 2025,
        "kind": "obligation_period",
        "label": "2024-2025",
        "start_year": 2024
       },
       "precision": 0,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "MWh",
       "value": 0.0
      },
      "issuer": "Washington State Department of Commerce",
      "kind": "filed_achievement",
      "locator": "cell E17",
      "method": "curated",
      "metric": "excess_conservation_prior_bienniums_mwh",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "Commerce's column E.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2026-06-01",
       "end_year": 2025,
       "kind": "obligation_period",
       "label": "2024-2025",
       "start_year": 2024
      },
      "source_publisher": "Washington State Department of Commerce",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://deptofcommerce.app.box.com/index.php?rm=box_download_shared_file&shared_name=y27oz4btzu41qjzorjijhy44xquuoa1u&file_id=f_2394988863865",
      "standing": "compiled",
      "state": "WA",
      "statement": "excess conservation carried from the prior two bienniums toward the 2024-2025 target",
      "unit": "MWh",
      "value": 0.0
     },
     {
      "as_of": "2026-06-01",
      "assertion_id": "eia-15500-filed_achievement-conservation-mwh-2025",
      "basis": null,
      "curation": {
       "checked": "2026-09-27",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w55"
      },
      "docket": null,
      "document": "EIA 2026 Report Summary and Detail.xlsx, sheet Conservation by Utility",
      "evidence": "reported",
      "fact": {
       "basis": "What the utility itself reported for the period in MWh; the utility's account, not the issuing body's finding",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/eia-15500-filed_achievement-conservation-mwh-2025#policy_filed_mwh",
       "label": "conservation acquired in 2025",
       "locator": "eia-15500-filed_achievement-conservation-mwh-2025; EIA 2026 Report Summary and Detail.xlsx, sheet Conservation by Utility; cell D17",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_filed_mwh",
       "missing_reason": null,
       "note": "Counts toward the 2024-2025 biennial target.",
       "period": {
        "as_of": "2026-06-01",
        "end_year": 2025,
        "kind": "obligation_period",
        "label": "2025",
        "start_year": 2025
       },
       "precision": 0,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "MWh",
       "value": 293527.0
      },
      "issuer": "Washington State Department of Commerce",
      "kind": "filed_achievement",
      "locator": "cell D17",
      "method": "curated",
      "metric": "conservation_mwh",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "Counts toward the 2024-2025 biennial target.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2026-06-01",
       "end_year": 2025,
       "kind": "obligation_period",
       "label": "2025",
       "start_year": 2025
      },
      "source_publisher": "Washington State Department of Commerce",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://deptofcommerce.app.box.com/index.php?rm=box_download_shared_file&shared_name=y27oz4btzu41qjzorjijhy44xquuoa1u&file_id=f_2394988863865",
      "standing": "compiled",
      "state": "WA",
      "statement": "conservation acquired in 2025",
      "unit": "MWh",
      "value": 293527.0
     },
     {
      "as_of": "2026-09-18",
      "assertion_id": "eia-15500-filed_achievement-qualifying-renewables-mwh-2026",
      "basis": null,
      "curation": {
       "checked": "2026-09-18",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-4b4"
      },
      "docket": null,
      "document": "EIA 2026 Report Summary and Detail.xlsx, sheet Renewable by Utility",
      "evidence": "reported",
      "fact": {
       "basis": "What the utility itself reported for the period in MWh; the utility's account, not the issuing body's finding",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/eia-15500-filed_achievement-qualifying-renewables-mwh-2026#policy_filed_mwh",
       "label": "qualifying renewable resources acquired for 2026",
       "locator": "eia-15500-filed_achievement-qualifying-renewables-mwh-2026; EIA 2026 Report Summary and Detail.xlsx, sheet Renewable by Utility",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_filed_mwh",
       "missing_reason": null,
       "note": "Equal to 0.15 of average load 2024-2025; 2025 qualifying renewables were 3174553.2 MWh. Incremental cost of eligible renewables as a share of revenue requirement 0.007212.",
       "period": {
        "as_of": "2026-09-18",
        "end_year": 2026,
        "kind": "obligation_period",
        "label": "2026",
        "start_year": 2026
       },
       "precision": 0,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "MWh",
       "value": 3176718.0
      },
      "issuer": "Washington State Department of Commerce",
      "kind": "filed_achievement",
      "locator": null,
      "method": "curated",
      "metric": "qualifying_renewables_mwh",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "Equal to 0.15 of average load 2024-2025; 2025 qualifying renewables were 3174553.2 MWh. Incremental cost of eligible renewables as a share of revenue requirement 0.007212.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2026-09-18",
       "end_year": 2026,
       "kind": "obligation_period",
       "label": "2026",
       "start_year": 2026
      },
      "source_publisher": "Washington State Department of Commerce",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://deptofcommerce.app.box.com/index.php?rm=box_download_shared_file&shared_name=y27oz4btzu41qjzorjijhy44xquuoa1u&file_id=f_2394988863865",
      "standing": "compiled",
      "state": "WA",
      "statement": "qualifying renewable resources acquired for 2026",
      "unit": "MWh",
      "value": 3176718.0
     }
    ],
    "instrument": "Biennial conservation acquisition target and an annual eligible-renewable target (15 percent of load from 2020) for utilities serving more than 25,000 Washington customers",
    "issuing_body": "Washington Utilities and Transportation Commission",
    "kinds_checked_absent": [
     "determination"
    ],
    "kinds_present": [
     "applicability",
     "deciding_event",
     "determination",
     "filed_achievement",
     "target"
    ],
    "name": "Energy Independence Act (Initiative 937)",
    "program_id": "eia",
    "review_due": 0,
    "statute": "RCW 19.285",
    "statute_url": "https://app.leg.wa.gov/RCW/default.aspx?cite=19.285",
    "targets": [
     {
      "as_of": "2006-11-07",
      "assertion_id": "eia-wa-target-renewable-share-of-load-2020",
      "basis": "of the qualifying utility's load",
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": null,
      "document": "RCW 19.285.040 Energy conservation and renewable energy targets",
      "evidence": "reported",
      "fact": {
       "basis": "of the qualifying utility's load",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/eia-wa-target-renewable-share-of-load-2020#policy_target_share",
       "label": "eligible renewable resources or renewable energy credits, or a combination, equal to at least 15 percent of load each year from 2020",
       "locator": "eia-wa-target-renewable-share-of-load-2020; RCW 19.285.040 Energy conservation and renewable energy targets; (2)(a)(iii)",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_target_share",
       "missing_reason": null,
       "note": "\"At least 15 percent of its load by January 1, 2020, and each year thereafter\" (2)(a)(iii), after 3 percent (2012-2015) and 9 percent (2016-2019). Initiative 937, approved 2006-11-07 (2007 c 1). Subsection (2) also provides alternative compliance paths (accelerated conservation and demand response; the four percent incremental-cost cap), so a utility can comply below 15 percent, as Clark Public Utilities does.",
       "period": {
        "as_of": "2006-11-07",
        "end_year": null,
        "kind": "obligation_period",
        "label": "2020-",
        "start_year": 2020
       },
       "precision": 1,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "percent",
       "value": 15.0
      },
      "issuer": "Washington State Legislature",
      "kind": "target",
      "locator": "(2)(a)(iii)",
      "method": "curated",
      "metric": "renewable_share_of_load",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "\"At least 15 percent of its load by January 1, 2020, and each year thereafter\" (2)(a)(iii), after 3 percent (2012-2015) and 9 percent (2016-2019). Initiative 937, approved 2006-11-07 (2007 c 1). Subsection (2) also provides alternative compliance paths (accelerated conservation and demand response; the four percent incremental-cost cap), so a utility can comply below 15 percent, as Clark Public Utilities does.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2006-11-07",
       "end_year": null,
       "kind": "obligation_period",
       "label": "2020-",
       "start_year": 2020
      },
      "source_publisher": "Washington State Legislature",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://app.leg.wa.gov/RCW/default.aspx?cite=19.285.040",
      "standing": "enacted",
      "state": "WA",
      "statement": "eligible renewable resources or renewable energy credits, or a combination, equal to at least 15 percent of load each year from 2020",
      "unit": "percent",
      "value": 15.0
     },
     {
      "as_of": "2024-01-17",
      "assertion_id": "eia-15500-target-conservation-mwh-2024-2025-ordered",
      "basis": null,
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-230892",
      "document": "Order 01 Accepting 2024-2033 Ten-Year Achievable Conservation Potential and 2024-2025 Biennial Conservation Target, Subject to Conditions",
      "evidence": "reported",
      "fact": {
       "basis": "A target in MWh as the statute, order or filing states it (conservation acquisition, eligible renewables); standing on the item says who set it",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/eia-15500-target-conservation-mwh-2024-2025-ordered#policy_target_mwh",
       "label": "2024-2025 biennial conservation acquisition target accepted by the commission",
       "locator": "eia-15500-target-conservation-mwh-2024-2025-ordered; Order 01 Accepting 2024-2033 Ten-Year Achievable Conservation Potential and 2024-2025 Biennial Conservation Target, Subject to Conditions; findings (7)-(9)",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_target_mwh",
       "missing_reason": null,
       "note": "\"PSE's calculation of its 2024-2025 biennial conservation target (EIA Target) of 304,400 MWh is consistent with RCW 19.285.040(1) and WAC 480-109-120(1)\"; the same order accepts an EIA Penalty Threshold of 268,702 MWh and a ten-year potential of 1,521,999 MWh. Commerce's 2026 report summary carries 268,702 MWh as PSE's target: that is the penalty threshold, not the target.",
       "period": {
        "as_of": "2024-01-17",
        "end_year": 2025,
        "kind": "obligation_period",
        "label": "2024-2025",
        "start_year": 2024
       },
       "precision": 0,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "MWh",
       "value": 304400.0
      },
      "issuer": "Washington Utilities and Transportation Commission",
      "kind": "target",
      "locator": "findings (7)-(9)",
      "method": "curated",
      "metric": "conservation_mwh",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "\"PSE's calculation of its 2024-2025 biennial conservation target (EIA Target) of 304,400 MWh is consistent with RCW 19.285.040(1) and WAC 480-109-120(1)\"; the same order accepts an EIA Penalty Threshold of 268,702 MWh and a ten-year potential of 1,521,999 MWh. Commerce's 2026 report summary carries 268,702 MWh as PSE's target: that is the penalty threshold, not the target.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2024-01-17",
       "end_year": 2025,
       "kind": "obligation_period",
       "label": "2024-2025",
       "start_year": 2024
      },
      "source_publisher": "Washington Utilities and Transportation Commission",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=28&year=2023&docketNumber=230892",
      "standing": "ordered",
      "state": "WA",
      "statement": "2024-2025 biennial conservation acquisition target accepted by the commission",
      "unit": "MWh",
      "value": 304400.0
     },
     {
      "as_of": "2024-01-17",
      "assertion_id": "eia-15500-target-conservation-penalty-threshold-2024-2025",
      "basis": null,
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-230892",
      "document": "Order 01 Accepting 2024-2033 Ten-Year Achievable Conservation Potential and 2024-2025 Biennial Conservation Target, Subject to Conditions",
      "evidence": "reported",
      "fact": {
       "basis": "A target in MWh as the statute, order or filing states it (conservation acquisition, eligible renewables); standing on the item says who set it",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/eia-15500-target-conservation-penalty-threshold-2024-2025#policy_target_mwh",
       "label": "2024-2025 EIA penalty threshold accepted by the commission",
       "locator": "eia-15500-target-conservation-penalty-threshold-2024-2025; Order 01 Accepting 2024-2033 Ten-Year Achievable Conservation Potential and 2024-2025 Biennial Conservation Target, Subject to Conditions; finding (9)",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_target_mwh",
       "missing_reason": null,
       "note": "\"PSE's calculation of its 2024-2025 EIA Penalty Threshold of 268,702 MWh is consistent with\" the rule. The threshold is the level below which RCW 19.285.060 penalties apply; the target is 304,400 MWh.",
       "period": {
        "as_of": "2024-01-17",
        "end_year": 2025,
        "kind": "obligation_period",
        "label": "2024-2025",
        "start_year": 2024
       },
       "precision": 0,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "MWh",
       "value": 268702.0
      },
      "issuer": "Washington Utilities and Transportation Commission",
      "kind": "target",
      "locator": "finding (9)",
      "method": "curated",
      "metric": "conservation_mwh",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "\"PSE's calculation of its 2024-2025 EIA Penalty Threshold of 268,702 MWh is consistent with\" the rule. The threshold is the level below which RCW 19.285.060 penalties apply; the target is 304,400 MWh.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2024-01-17",
       "end_year": 2025,
       "kind": "obligation_period",
       "label": "2024-2025",
       "start_year": 2024
      },
      "source_publisher": "Washington Utilities and Transportation Commission",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=28&year=2023&docketNumber=230892",
      "standing": "ordered",
      "state": "WA",
      "statement": "2024-2025 EIA penalty threshold accepted by the commission",
      "unit": "MWh",
      "value": 268702.0
     },
     {
      "as_of": "2026-06-01",
      "assertion_id": "eia-15500-target-conservation-mwh-2024-2025",
      "basis": "the commission's 2024-2025 EIA penalty threshold (UE-230892 Order 01), not its 304,400 MWh EIA target",
      "curation": {
       "checked": "2026-09-27",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-w55"
      },
      "docket": null,
      "document": "EIA 2026 Report Summary and Detail.xlsx, sheet Conservation by Utility",
      "evidence": "reported",
      "fact": {
       "basis": "the commission's 2024-2025 EIA penalty threshold (UE-230892 Order 01), not its 304,400 MWh EIA target",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/eia-15500-target-conservation-mwh-2024-2025#policy_target_mwh",
       "label": "biennial conservation acquisition target for 2024-2025",
       "locator": "eia-15500-target-conservation-mwh-2024-2025; EIA 2026 Report Summary and Detail.xlsx, sheet Conservation by Utility; cell B17",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_target_mwh",
       "missing_reason": null,
       "note": "Biennium 2024-2025. Prior biennium 2022-2023 target 536717.135 MWh; change from the 2022-2023 target -0.49936.",
       "period": {
        "as_of": "2026-06-01",
        "end_year": 2025,
        "kind": "obligation_period",
        "label": "2024-2025",
        "start_year": 2024
       },
       "precision": 0,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "MWh",
       "value": 268702.0
      },
      "issuer": "Washington State Department of Commerce",
      "kind": "target",
      "locator": "cell B17",
      "method": "curated",
      "metric": "conservation_mwh",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "Biennium 2024-2025. Prior biennium 2022-2023 target 536717.135 MWh; change from the 2022-2023 target -0.49936.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2026-06-01",
       "end_year": 2025,
       "kind": "obligation_period",
       "label": "2024-2025",
       "start_year": 2024
      },
      "source_publisher": "Washington State Department of Commerce",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://deptofcommerce.app.box.com/index.php?rm=box_download_shared_file&shared_name=y27oz4btzu41qjzorjijhy44xquuoa1u&file_id=f_2394988863865",
      "standing": "compiled",
      "state": "WA",
      "statement": "biennial conservation acquisition target for 2024-2025",
      "unit": "MWh",
      "value": 268702.0
     },
     {
      "as_of": "2026-01-14",
      "assertion_id": "eia-15500-target-conservation-mwh-2026-2027-ordered",
      "basis": null,
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2028-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-250834",
      "document": "Order 01 Accepting 2026-2035 Ten-Year Achievable Conservation Potential and 2026-2027 Biennial Conservation Target, Subject to Conditions",
      "evidence": "reported",
      "fact": {
       "basis": "A target in MWh as the statute, order or filing states it (conservation acquisition, eligible renewables); standing on the item says who set it",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/eia-15500-target-conservation-mwh-2026-2027-ordered#policy_target_mwh",
       "label": "2026-2027 biennial conservation acquisition target accepted by the commission",
       "locator": "eia-15500-target-conservation-mwh-2026-2027-ordered; Order 01 Accepting 2026-2035 Ten-Year Achievable Conservation Potential and 2026-2027 Biennial Conservation Target, Subject to Conditions; finding (7)",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_target_mwh",
       "missing_reason": null,
       "note": "\"PSE's calculation of its 2026-2027 EIA target of 193,228 MWh is consistent with RCW 19.285.040(1) and WAC 480-109-120(1)\"; the order also accepts a ten-year achievable potential of 966,140 MWh (2026-2035). Effective 2026-01-14.",
       "period": {
        "as_of": "2026-01-14",
        "end_year": 2027,
        "kind": "obligation_period",
        "label": "2026-2027",
        "start_year": 2026
       },
       "precision": 0,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "MWh",
       "value": 193228.0
      },
      "issuer": "Washington Utilities and Transportation Commission",
      "kind": "target",
      "locator": "finding (7)",
      "method": "curated",
      "metric": "conservation_mwh",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "\"PSE's calculation of its 2026-2027 EIA target of 193,228 MWh is consistent with RCW 19.285.040(1) and WAC 480-109-120(1)\"; the order also accepts a ten-year achievable potential of 966,140 MWh (2026-2035). Effective 2026-01-14.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2026-01-14",
       "end_year": 2027,
       "kind": "obligation_period",
       "label": "2026-2027",
       "start_year": 2026
      },
      "source_publisher": "Washington Utilities and Transportation Commission",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=37&year=2025&docketNumber=250834",
      "standing": "ordered",
      "state": "WA",
      "statement": "2026-2027 biennial conservation acquisition target accepted by the commission",
      "unit": "MWh",
      "value": 193228.0
     },
     {
      "as_of": "2026-01-14",
      "assertion_id": "eia-15500-target-conservation-penalty-threshold-2026-2027",
      "basis": null,
      "curation": {
       "checked": "2026-09-21",
       "review_after": "2028-07-01",
       "review_due": false,
       "reviewer": "claude-w14"
      },
      "docket": "UE-250834",
      "document": "Order 01 Accepting 2026-2035 Ten-Year Achievable Conservation Potential and 2026-2027 Biennial Conservation Target, Subject to Conditions",
      "evidence": "reported",
      "fact": {
       "basis": "A target in MWh as the statute, order or filing states it (conservation acquisition, eligible renewables); standing on the item says who set it",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/eia-15500-target-conservation-penalty-threshold-2026-2027#policy_target_mwh",
       "label": "2026-2027 EIA penalty threshold accepted by the commission",
       "locator": "eia-15500-target-conservation-penalty-threshold-2026-2027; Order 01 Accepting 2026-2035 Ten-Year Achievable Conservation Potential and 2026-2027 Biennial Conservation Target, Subject to Conditions; finding (9)",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_target_mwh",
       "missing_reason": null,
       "note": "\"PSE's calculation of its 2026-2027 EIA penalty threshold of 156,781 MWh is consistent with\" the rule; decoupling penalty threshold 9,661 MWh.",
       "period": {
        "as_of": "2026-01-14",
        "end_year": 2027,
        "kind": "obligation_period",
        "label": "2026-2027",
        "start_year": 2026
       },
       "precision": 0,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "MWh",
       "value": 156781.0
      },
      "issuer": "Washington Utilities and Transportation Commission",
      "kind": "target",
      "locator": "finding (9)",
      "method": "curated",
      "metric": "conservation_mwh",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "\"PSE's calculation of its 2026-2027 EIA penalty threshold of 156,781 MWh is consistent with\" the rule; decoupling penalty threshold 9,661 MWh.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2026-01-14",
       "end_year": 2027,
       "kind": "obligation_period",
       "label": "2026-2027",
       "start_year": 2026
      },
      "source_publisher": "Washington Utilities and Transportation Commission",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://apiproxy.utc.wa.gov/cases/GetDocument?docID=37&year=2025&docketNumber=250834",
      "standing": "ordered",
      "state": "WA",
      "statement": "2026-2027 EIA penalty threshold accepted by the commission",
      "unit": "MWh",
      "value": 156781.0
     },
     {
      "as_of": "2026-09-18",
      "assertion_id": "eia-15500-target-renewable-share-of-load-2026",
      "basis": "of average load 2024-2025",
      "curation": {
       "checked": "2026-09-18",
       "review_after": "2027-07-01",
       "review_due": false,
       "reviewer": "claude-4b4"
      },
      "docket": null,
      "document": "EIA 2026 Report Summary and Detail.xlsx, sheet Renewable by Utility",
      "evidence": "reported",
      "fact": {
       "basis": "of average load 2024-2025",
       "coverage": null,
       "denominator": null,
       "evidence": "reported",
       "fact_id": "org:eia:15500/obligation/eia-15500-target-renewable-share-of-load-2026#policy_target_share",
       "label": "renewable energy target for 2026",
       "locator": "eia-15500-target-renewable-share-of-load-2026; EIA 2026 Report Summary and Detail.xlsx, sheet Renewable by Utility",
       "maturity": "final",
       "method": "curated",
       "metric": "policy_target_share",
       "missing_reason": null,
       "note": "Average load 2024-2025 21178119 MWh.",
       "period": {
        "as_of": "2026-09-18",
        "end_year": 2026,
        "kind": "obligation_period",
        "label": "2026",
        "start_year": 2026
       },
       "precision": 6,
       "quality": "valid",
       "source_ref": "clean-energy-obligations",
       "unit": "fraction",
       "value": 0.15
      },
      "issuer": "Washington State Department of Commerce",
      "kind": "target",
      "locator": null,
      "method": "curated",
      "metric": "renewable_share_of_load",
      "missing_reason": null,
      "next_step": null,
      "next_step_date": null,
      "note": "Average load 2024-2025 21178119 MWh.",
      "participation_url": null,
      "percent_decimals": null,
      "period": {
       "as_of": "2026-09-18",
       "end_year": 2026,
       "kind": "obligation_period",
       "label": "2026",
       "start_year": 2026
      },
      "source_publisher": "Washington State Department of Commerce",
      "source_ref": "clean-energy-obligations",
      "source_url": "https://deptofcommerce.app.box.com/index.php?rm=box_download_shared_file&shared_name=y27oz4btzu41qjzorjijhy44xquuoa1u&file_id=f_2394988863865",
      "standing": "compiled",
      "state": "WA",
      "statement": "renewable energy target for 2026",
      "unit": "fraction",
      "value": 0.15
     }
    ],
    "uncertainties": [
     {
      "anchor": "docs/research/2026-09-18-policy-sources.md#21-obligations-statute-text",
      "id": "sao-count",
      "resolution": null,
      "status": "open",
      "text": "SAO says it examines \"13 qualifying utilities\" for EIA and \"39 qualifying utilities\" for CETA — the count difference (18 vs 13) is unexplained; cooperatives are audited independently."
     },
     {
      "anchor": "docs/research/2026-09-18-policy-sources.md#21-obligations-statute-text",
      "id": "biennial-2026",
      "resolution": null,
      "status": "open",
      "text": "After June 12, 2026, utilities will shift from annual reporting on EIA compliance progress to biennial reporting."
     },
     {
      "anchor": "docs/research/2026-09-18-policy-sources.md#24-eia-compliance-summaries",
      "id": "utc-2022-snapshot",
      "resolution": null,
      "status": "open",
      "text": "\"PSE exceeded its commission-approved target of 3,084,363 megawatt hours … acquiring 3,794,770\" (news 2022, snapshot)."
     },
     {
      "anchor": "docs/source-contracts.md#clean-energy-obligations--clean-energy-obligations-curated",
      "id": "commerce-target-threshold",
      "resolution": null,
      "status": "open",
      "text": "Commerce's 2026 report summary carries the 2024-2025 conservation target for Puget Sound Energy as 268,702 MWh; the commission's Order 01 in UE-230892 accepted a target of 304,400 MWh and a penalty threshold of 268,702 MWh."
     }
    ]
   }
  ],
  "rules": [
   "A fuel-mix value is not a compliance verdict: the disclosed-supply block reports what a utility sold by category as Commerce computed it; compliance is what the issuing body decides on the utility's filing, and that decision is a determination row here.",
   "A filing that restates a target does not enact it: only rows with standing enacted or ordered are the obligation; standing filed, proposed or compiled is the utility's or an agency's expression of it."
  ],
  "source_ref": "clean-energy-obligations"
 },
 "operates": [
  {
   "id": "plant:eia:57195",
   "name": "Lower Snake River Wind Energy Project",
   "nameplate_mw_op": 342.7,
   "state": "WA"
  },
  {
   "id": "plant:eia:55700",
   "name": "Mint Farm Generating Station",
   "nameplate_mw_op": 319.0,
   "state": "WA"
  },
  {
   "id": "plant:eia:55482",
   "name": "Goldendale Generating Station",
   "nameplate_mw_op": 302.8,
   "state": "WA"
  },
  {
   "id": "plant:eia:54537",
   "name": "Ferndale Generating Station",
   "nameplate_mw_op": 285.5,
   "state": "WA"
  },
  {
   "id": "plant:eia:56322",
   "name": "Wild Horse",
   "nameplate_mw_op": 273.1,
   "state": "WA"
  },
  {
   "id": "plant:eia:99",
   "name": "Frederickson",
   "nameplate_mw_op": 177.8,
   "state": "WA"
  },
  {
   "id": "plant:eia:7870",
   "name": "Encogen",
   "nameplate_mw_op": 176.39999999999998,
   "state": "WA"
  },
  {
   "id": "plant:eia:6120",
   "name": "Whitehorn",
   "nameplate_mw_op": 169.2,
   "state": "WA"
  },
  {
   "id": "plant:eia:56255",
   "name": "Hopkins Ridge Wind",
   "nameplate_mw_op": 156.6,
   "state": "WA"
  },
  {
   "id": "plant:eia:54476",
   "name": "Sumas Power Plant",
   "nameplate_mw_op": 125.5,
   "state": "WA"
  },
  {
   "id": "plant:eia:3861",
   "name": "Upper Baker",
   "nameplate_mw_op": 104.8,
   "state": "WA"
  },
  {
   "id": "plant:eia:3855",
   "name": "Lower Baker",
   "nameplate_mw_op": 103.9,
   "state": "WA"
  },
  {
   "id": "plant:eia:7867",
   "name": "Snoqualmie 2",
   "nameplate_mw_op": 38.7,
   "state": "WA"
  },
  {
   "id": "plant:eia:3860",
   "name": "Snoqualmie",
   "nameplate_mw_op": 12.8,
   "state": "WA"
  },
  {
   "id": "plant:eia:60444",
   "name": "Glacier Battery Storage",
   "nameplate_mw_op": 2.0,
   "state": "WA"
  },
  {
   "id": "plant:eia:607",
   "name": "Fredonia",
   "nameplate_mw_op": 0.0,
   "state": "WA"
  },
  {
   "id": "plant:eia:3853",
   "name": "Crystal Mountain",
   "nameplate_mw_op": 0.0,
   "state": "WA"
  },
  {
   "id": "plant:eia:3862",
   "name": "White River (WA)",
   "nameplate_mw_op": 0.0,
   "state": "WA"
  },
  {
   "id": "plant:eia:65019",
   "name": "Beaver Creek Wind Facility",
   "nameplate_mw_op": 0.0,
   "state": "MT"
  }
 ],
 "oregon_supply": {
  "available": false,
  "note": "Not an electricity supplier in DEQ's Oregon workbook (2010–2024 loaded), or not linked by the reviewed supplier crosswalk",
  "reason": "not_a_supplier"
 },
 "owns": [
  {
   "bases": [
    "reported_schedule"
   ],
   "generators": 2,
   "id": "plant:eia:6076",
   "name": "Colstrip Steam Electric Station",
   "owned_mw": 411.85,
   "state": "MT"
  },
  {
   "bases": [
    "eia860_schedule4_default"
   ],
   "generators": 1,
   "id": "plant:eia:57195",
   "name": "Lower Snake River Wind Energy Project",
   "owned_mw": 342.7,
   "state": "WA"
  },
  {
   "bases": [
    "eia860_schedule4_default"
   ],
   "generators": 2,
   "id": "plant:eia:55700",
   "name": "Mint Farm Generating Station",
   "owned_mw": 319.0,
   "state": "WA"
  },
  {
   "bases": [
    "eia860_schedule4_default"
   ],
   "generators": 2,
   "id": "plant:eia:55482",
   "name": "Goldendale Generating Station",
   "owned_mw": 302.8,
   "state": "WA"
  },
  {
   "bases": [
    "eia860_schedule4_default"
   ],
   "generators": 3,
   "id": "plant:eia:54537",
   "name": "Ferndale Generating Station",
   "owned_mw": 285.5,
   "state": "WA"
  },
  {
   "bases": [
    "eia860_schedule4_default"
   ],
   "generators": 3,
   "id": "plant:eia:56322",
   "name": "Wild Horse",
   "owned_mw": 273.1,
   "state": "WA"
  },
  {
   "bases": [
    "eia860_schedule4_default"
   ],
   "generators": 2,
   "id": "plant:eia:99",
   "name": "Frederickson",
   "owned_mw": 177.8,
   "state": "WA"
  },
  {
   "bases": [
    "eia860_schedule4_default"
   ],
   "generators": 4,
   "id": "plant:eia:7870",
   "name": "Encogen",
   "owned_mw": 176.4,
   "state": "WA"
  },
  {
   "bases": [
    "eia860_schedule4_default"
   ],
   "generators": 2,
   "id": "plant:eia:6120",
   "name": "Whitehorn",
   "owned_mw": 169.2,
   "state": "WA"
  },
  {
   "bases": [
    "reported_schedule"
   ],
   "generators": 2,
   "id": "plant:eia:55818",
   "name": "Frederickson 1 Generating Station",
   "owned_mw": 158.673,
   "state": "WA"
  },
  {
   "bases": [
    "eia860_schedule4_default"
   ],
   "generators": 2,
   "id": "plant:eia:56255",
   "name": "Hopkins Ridge Wind",
   "owned_mw": 156.6,
   "state": "WA"
  },
  {
   "bases": [
    "eia860_schedule4_default"
   ],
   "generators": 2,
   "id": "plant:eia:54476",
   "name": "Sumas Power Plant",
   "owned_mw": 125.5,
   "state": "WA"
  },
  {
   "bases": [
    "eia860_schedule4_default"
   ],
   "generators": 2,
   "id": "plant:eia:3861",
   "name": "Upper Baker",
   "owned_mw": 104.8,
   "state": "WA"
  },
  {
   "bases": [
    "eia860_schedule4_default"
   ],
   "generators": 2,
   "id": "plant:eia:3855",
   "name": "Lower Baker",
   "owned_mw": 103.9,
   "state": "WA"
  },
  {
   "bases": [
    "eia860_schedule4_default"
   ],
   "generators": 2,
   "id": "plant:eia:7867",
   "name": "Snoqualmie 2",
   "owned_mw": 38.7,
   "state": "WA"
  },
  {
   "bases": [
    "eia860_schedule4_default"
   ],
   "generators": 5,
   "id": "plant:eia:3860",
   "name": "Snoqualmie",
   "owned_mw": 12.8,
   "state": "WA"
  },
  {
   "bases": [
    "eia860_schedule4_default"
   ],
   "generators": 1,
   "id": "plant:eia:60444",
   "name": "Glacier Battery Storage",
   "owned_mw": 2.0,
   "state": "WA"
  }
 ],
 "programmes": {
  "coverage": {
   "bucket": false,
   "demand_response": {
    "classes_filed": [
     "commercial",
     "industrial",
     "residential"
    ],
    "comparison_year_reason": null,
    "short_form_years": [],
    "states": [
     "WA"
    ],
    "years_filed": [
     2023,
     2024
    ],
    "years_listed_without_values": [],
    "years_without_row": [
     2013,
     2014,
     2015,
     2016,
     2017,
     2018,
     2019,
     2020,
     2021,
     2022
    ]
   },
   "energy_efficiency": {
    "classes_filed": [
     "commercial",
     "industrial",
     "residential",
     "total",
     "transportation"
    ],
    "comparison_year_reason": null,
    "short_form_years": [],
    "states": [
     "WA"
    ],
    "years_filed": [
     2013,
     2014,
     2015,
     2016,
     2017,
     2018,
     2019,
     2020,
     2021,
     2022,
     2023,
     2024
    ],
    "years_listed_without_values": [],
    "years_without_row": []
   },
   "long_form_respondent": true,
   "note": "Population: organizations of this release with EIA-861 rows in the core states. A short-form respondent has no figures to file; a long-form respondent without a row may have no programmes or may have a nonutility administrator reporting for it. Years without a row are listed against the table's span, not against the years this utility filed the form.",
   "short_form_respondent": false,
   "table_years": [
    2013,
    2024
   ],
   "year": 2024
  },
  "demand_response": {
   "available": true,
   "form_part": "EIA-861 Schedule 6 Part B",
   "metric_definitions": {
    "actual_peak_demand_savings_mw": {
     "basis": "achieved",
     "form_line": "4",
     "horizon": "reporting_year",
     "label": "Actual peak demand savings at the annual system peak hour",
     "unit": "MW"
    },
    "customer_incentives_cost": {
     "basis": "reported",
     "form_line": "5",
     "horizon": "reporting_year",
     "label": "Customer incentives (nominal)",
     "unit": "USD"
    },
    "customers": {
     "basis": "reported",
     "form_line": "1",
     "horizon": "reporting_year",
     "label": "Customers enrolled in demand response programmes",
     "unit": "count"
    },
    "customers_share_of_retail": {
     "basis": "derived",
     "form_line": null,
     "horizon": "reporting_year",
     "label": "Enrolled customers as a share of the utility's EIA-861 customers (retail_observation), same state, class and year",
     "unit": "share"
    },
    "energy_savings_mwh": {
     "basis": "reported",
     "form_line": "2",
     "horizon": "reporting_year",
     "label": "Energy savings from demand response",
     "unit": "MWh"
    },
    "other_costs": {
     "basis": "reported",
     "form_line": "6",
     "horizon": "reporting_year",
     "label": "Other programme costs (nominal)",
     "unit": "USD"
    },
    "potential_peak_demand_savings_mw": {
     "basis": "potential",
     "form_line": "3",
     "horizon": "reporting_year",
     "label": "Potential peak demand savings, all demand response called",
     "unit": "MW"
    }
   },
   "note": "Reported by the utility on EIA-861 Schedule 6 Part B. Potential peak savings assume every programme is called; actual peak savings are what was achieved at the company's own annual peak hour, and the two are never merged. Customers are enrolled customers, a count. Costs are nominal dollars of the report year. The form has no total row and none is computed here. A blank stays blank.",
   "programme": "demand_response",
   "rows": [
    {
     "ba_code": "PSEI",
     "customer_class": "commercial",
     "customers_share_of_retail": {
      "basis": "customers enrolled in demand response ÷ customers on every EIA-861 sales row of the same utility, state, customer class and report year (retail_observation: all business models and service types), both from Form EIA-861 for 2023",
      "denominator": {
       "column": "customers",
       "rows": 0,
       "table": "retail_observation",
       "unit": "count",
       "value": null
      },
      "method": "derived",
      "missing_reason": "denominator_not_loaded",
      "note": "retail_observation holds the comparison year only (2024)",
      "numerator": {
       "metric": "customers",
       "unit": "count",
       "value": null
      },
      "unit": "share",
      "value": null
     },
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "actual_peak_demand_savings_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "customer_incentives_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "customers": {
       "missing_reason": "not_reported",
       "unit": "count",
       "value": null
      },
      "energy_savings_mwh": {
       "missing_reason": "not_reported",
       "unit": "MWh",
       "value": null
      },
      "other_costs": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "potential_peak_demand_savings_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2023
    },
    {
     "ba_code": "PSEI",
     "customer_class": "industrial",
     "customers_share_of_retail": {
      "basis": "customers enrolled in demand response ÷ customers on every EIA-861 sales row of the same utility, state, customer class and report year (retail_observation: all business models and service types), both from Form EIA-861 for 2023",
      "denominator": {
       "column": "customers",
       "rows": 0,
       "table": "retail_observation",
       "unit": "count",
       "value": null
      },
      "method": "derived",
      "missing_reason": "denominator_not_loaded",
      "note": "retail_observation holds the comparison year only (2024)",
      "numerator": {
       "metric": "customers",
       "unit": "count",
       "value": null
      },
      "unit": "share",
      "value": null
     },
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "actual_peak_demand_savings_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "customer_incentives_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "customers": {
       "missing_reason": "not_reported",
       "unit": "count",
       "value": null
      },
      "energy_savings_mwh": {
       "missing_reason": "not_reported",
       "unit": "MWh",
       "value": null
      },
      "other_costs": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "potential_peak_demand_savings_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2023
    },
    {
     "ba_code": "PSEI",
     "customer_class": "residential",
     "customers_share_of_retail": {
      "basis": "customers enrolled in demand response ÷ customers on every EIA-861 sales row of the same utility, state, customer class and report year (retail_observation: all business models and service types), both from Form EIA-861 for 2023",
      "denominator": {
       "column": "customers",
       "rows": 0,
       "table": "retail_observation",
       "unit": "count",
       "value": null
      },
      "method": "derived",
      "missing_reason": "denominator_not_loaded",
      "note": "retail_observation holds the comparison year only (2024)",
      "numerator": {
       "metric": "customers",
       "unit": "count",
       "value": 524866.0
      },
      "unit": "share",
      "value": null
     },
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "actual_peak_demand_savings_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 18.02
      },
      "customer_incentives_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 1044464.9999999999
      },
      "customers": {
       "missing_reason": null,
       "unit": "count",
       "value": 524866.0
      },
      "energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 60.48
      },
      "other_costs": {
       "missing_reason": null,
       "unit": "USD",
       "value": 1865556.0
      },
      "potential_peak_demand_savings_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 24.74
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2023
    },
    {
     "ba_code": "PSEI",
     "customer_class": "transportation",
     "customers_share_of_retail": {
      "basis": "customers enrolled in demand response ÷ customers on every EIA-861 sales row of the same utility, state, customer class and report year (retail_observation: all business models and service types), both from Form EIA-861 for 2023",
      "denominator": {
       "column": "customers",
       "rows": 0,
       "table": "retail_observation",
       "unit": "count",
       "value": null
      },
      "method": "derived",
      "missing_reason": "denominator_not_loaded",
      "note": "retail_observation holds the comparison year only (2024)",
      "numerator": {
       "metric": "customers",
       "unit": "count",
       "value": null
      },
      "unit": "share",
      "value": null
     },
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "actual_peak_demand_savings_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "customer_incentives_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "customers": {
       "missing_reason": "not_reported",
       "unit": "count",
       "value": null
      },
      "energy_savings_mwh": {
       "missing_reason": "not_reported",
       "unit": "MWh",
       "value": null
      },
      "other_costs": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "potential_peak_demand_savings_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2023
    },
    {
     "ba_code": "PSEI",
     "customer_class": "commercial",
     "customers_share_of_retail": {
      "basis": "customers enrolled in demand response ÷ customers on every EIA-861 sales row of the same utility, state, customer class and report year (retail_observation: all business models and service types), both from Form EIA-861 for 2024",
      "denominator": {
       "column": "customers",
       "rows": 2,
       "table": "retail_observation",
       "unit": "count",
       "value": 143363.0
      },
      "method": "derived",
      "missing_reason": null,
      "note": null,
      "numerator": {
       "metric": "customers",
       "unit": "count",
       "value": 301.0
      },
      "unit": "share",
      "value": 0.0020995654387812755
     },
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "actual_peak_demand_savings_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 3.4
      },
      "customer_incentives_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 171000.0
      },
      "customers": {
       "missing_reason": null,
       "unit": "count",
       "value": 301.0
      },
      "energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 27.9
      },
      "other_costs": {
       "missing_reason": null,
       "unit": "USD",
       "value": 401000.0
      },
      "potential_peak_demand_savings_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 4.1
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2024
    },
    {
     "ba_code": "PSEI",
     "customer_class": "industrial",
     "customers_share_of_retail": {
      "basis": "customers enrolled in demand response ÷ customers on every EIA-861 sales row of the same utility, state, customer class and report year (retail_observation: all business models and service types), both from Form EIA-861 for 2024",
      "denominator": {
       "column": "customers",
       "rows": 2,
       "table": "retail_observation",
       "unit": "count",
       "value": 3188.0
      },
      "method": "derived",
      "missing_reason": null,
      "note": null,
      "numerator": {
       "metric": "customers",
       "unit": "count",
       "value": 19.0
      },
      "unit": "share",
      "value": 0.005959849435382685
     },
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "actual_peak_demand_savings_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 9.1
      },
      "customer_incentives_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 385000.0
      },
      "customers": {
       "missing_reason": null,
       "unit": "count",
       "value": 19.0
      },
      "energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 40.2
      },
      "other_costs": {
       "missing_reason": null,
       "unit": "USD",
       "value": 899000.0
      },
      "potential_peak_demand_savings_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 9.2
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2024
    },
    {
     "ba_code": "PSEI",
     "customer_class": "residential",
     "customers_share_of_retail": {
      "basis": "customers enrolled in demand response ÷ customers on every EIA-861 sales row of the same utility, state, customer class and report year (retail_observation: all business models and service types), both from Form EIA-861 for 2024",
      "denominator": {
       "column": "customers",
       "rows": 2,
       "table": "retail_observation",
       "unit": "count",
       "value": 1091599.0
      },
      "method": "derived",
      "missing_reason": null,
      "note": null,
      "numerator": {
       "metric": "customers",
       "unit": "count",
       "value": 601946.0
      },
      "unit": "share",
      "value": 0.5514350965876663
     },
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "actual_peak_demand_savings_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 52.9
      },
      "customer_incentives_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 3606000.0
      },
      "customers": {
       "missing_reason": null,
       "unit": "count",
       "value": 601946.0
      },
      "energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 1758.5
      },
      "other_costs": {
       "missing_reason": null,
       "unit": "USD",
       "value": 5178000.0
      },
      "potential_peak_demand_savings_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 53.0
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2024
    },
    {
     "ba_code": "PSEI",
     "customer_class": "transportation",
     "customers_share_of_retail": {
      "basis": "customers enrolled in demand response ÷ customers on every EIA-861 sales row of the same utility, state, customer class and report year (retail_observation: all business models and service types), both from Form EIA-861 for 2024",
      "denominator": {
       "column": "customers",
       "rows": 2,
       "table": "retail_observation",
       "unit": "count",
       "value": 1.0
      },
      "method": "derived",
      "missing_reason": "not_reported",
      "note": null,
      "numerator": {
       "metric": "customers",
       "unit": "count",
       "value": null
      },
      "unit": "share",
      "value": null
     },
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "actual_peak_demand_savings_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "customer_incentives_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "customers": {
       "missing_reason": "not_reported",
       "unit": "count",
       "value": null
      },
      "energy_savings_mwh": {
       "missing_reason": "not_reported",
       "unit": "MWh",
       "value": null
      },
      "other_costs": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "potential_peak_demand_savings_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2024
    }
   ],
   "source_ref": "pudl-eia861-demand-response",
   "years": [
    2023,
    2024
   ]
  },
  "energy_efficiency": {
   "available": true,
   "form_part": "EIA-861 Schedule 6 Part A",
   "metric_definitions": {
    "customer_incentives_incremental_cost": {
     "basis": "reported",
     "form_line": "5-8",
     "horizon": "reporting_year",
     "label": "Customer incentives, reporting-year incremental cost (nominal)",
     "unit": "USD"
    },
    "customer_incentives_incremental_life_cycle_cost": {
     "basis": "reported",
     "form_line": "5-8",
     "horizon": "life_cycle",
     "label": "Customer incentives, incremental life-cycle cost (nominal)",
     "unit": "USD"
    },
    "customer_other_costs_incremental_life_cycle_cost": {
     "basis": "reported",
     "form_line": "5-8",
     "horizon": "life_cycle",
     "label": "Other costs, incremental life-cycle (nominal)",
     "unit": "USD"
    },
    "incremental_energy_savings_mwh": {
     "basis": "reported",
     "form_line": "1",
     "horizon": "reporting_year",
     "label": "Incremental annual energy savings, reporting year (annualized)",
     "unit": "MWh"
    },
    "incremental_life_cycle_energy_savings_mwh": {
     "basis": "reported",
     "form_line": "3",
     "horizon": "life_cycle",
     "label": "Incremental life-cycle energy savings (lump sum over the programmes' life)",
     "unit": "MWh"
    },
    "incremental_life_cycle_peak_reduction_mw": {
     "basis": "reported",
     "form_line": "4",
     "horizon": "life_cycle",
     "label": "Incremental life-cycle peak demand savings (average annual over the programmes' life)",
     "unit": "MW"
    },
    "incremental_peak_reduction_mw": {
     "basis": "reported",
     "form_line": "2",
     "horizon": "reporting_year",
     "label": "Incremental annual peak demand savings, reporting year",
     "unit": "MW"
    },
    "other_costs_incremental_cost": {
     "basis": "reported",
     "form_line": "5-8",
     "horizon": "reporting_year",
     "label": "Other costs, reporting-year incremental (nominal)",
     "unit": "USD"
    },
    "weighted_average_life_years": {
     "basis": "reported",
     "form_line": "10",
     "horizon": "portfolio",
     "label": "Weighted average life of the energy-efficiency portfolio",
     "unit": "years"
    }
   },
   "note": "Reported by the utility on EIA-861 Schedule 6 Part A as adjusted gross savings at the customer meter under its own evaluation; figures are not comparable across utilities. Reporting-year incremental savings are annualized for participants new that year; life-cycle savings run over the programmes' planned life (energy as a lump sum, peak as the average annual reduction). Each class is shown as filed and the total row is the filer's own; nothing is summed here. Costs are nominal dollars of the report year (the form collects thousands; PUDL publishes dollars). A blank stays blank.",
   "programme": "energy_efficiency",
   "rows": [
    {
     "ba_code": "PSEI",
     "customer_class": "commercial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 25517000.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 263193000.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 81280000.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 150963.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 1385832.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 17.4
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 8312000.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 4.0
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2013
    },
    {
     "ba_code": "PSEI",
     "customer_class": "industrial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 2835000.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 29244000.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 9031000.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 16773.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 153981.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 1.9
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 924000.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 4.0
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2013
    },
    {
     "ba_code": "PSEI",
     "customer_class": "residential",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 40925000.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 674174000.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 145966000.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 172927.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 2707069.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 28.5
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 9181000.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 7.0
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2013
    },
    {
     "ba_code": "PSEI",
     "customer_class": "transportation",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 0.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 0.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 0.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 0.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 0.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 0.0
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 0.0
      },
      "weighted_average_life_years": {
       "missing_reason": "not_reported",
       "unit": "years",
       "value": null
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2013
    },
    {
     "ba_code": "PSEI",
     "customer_class": "total",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 69277000.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 966611000.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 236277000.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 340663.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 4246882.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 47.8
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 18417000.0
      }
     },
     "reported_total": true,
     "short_form": null,
     "state": "WA",
     "year": 2013
    },
    {
     "ba_code": "PSEI",
     "customer_class": "commercial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 25112000.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 25112000.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 11711000.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 133946.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 1386027.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 35.1
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 28.7
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 11711000.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 9.31
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2014
    },
    {
     "ba_code": "PSEI",
     "customer_class": "industrial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 2790000.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 2790000.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 1301000.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 14822.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 154003.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 3.9
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 3.2
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 1301000.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 1.03
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2014
    },
    {
     "ba_code": "PSEI",
     "customer_class": "residential",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 43369000.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 43369000.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 8565000.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 151259.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 1922191.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 105.5
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 32.0
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 8565000.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 12.71
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2014
    },
    {
     "ba_code": "PSEI",
     "customer_class": "transportation",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": "not_reported",
       "unit": "MWh",
       "value": null
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": "not_reported",
       "unit": "MWh",
       "value": null
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "other_costs_incremental_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "weighted_average_life_years": {
       "missing_reason": "not_reported",
       "unit": "years",
       "value": null
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2014
    },
    {
     "ba_code": "PSEI",
     "customer_class": "total",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 71271000.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 71271000.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 21577000.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 300027.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 3462221.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 144.5
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 63.9
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 21577000.0
      }
     },
     "reported_total": true,
     "short_form": null,
     "state": "WA",
     "year": 2014
    },
    {
     "ba_code": "PSEI",
     "customer_class": "commercial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 20664000.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 20664000.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 7994000.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 113136.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 1180582.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 13.3
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 23.9
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 7994000.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 11.39
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2015
    },
    {
     "ba_code": "PSEI",
     "customer_class": "industrial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 2296000.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 2296000.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 888000.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 12570.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 131176.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 1.5
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 2.7
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 888000.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 1.26
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2015
    },
    {
     "ba_code": "PSEI",
     "customer_class": "residential",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 42756000.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 42756000.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 8037000.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 156854.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 1963866.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 104.2
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 28.1
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 8037000.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 18.54
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2015
    },
    {
     "ba_code": "PSEI",
     "customer_class": "transportation",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": "not_reported",
       "unit": "MWh",
       "value": null
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": "not_reported",
       "unit": "MWh",
       "value": null
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "other_costs_incremental_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "weighted_average_life_years": {
       "missing_reason": "not_reported",
       "unit": "years",
       "value": null
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2015
    },
    {
     "ba_code": "PSEI",
     "customer_class": "total",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 65716000.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 65716000.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 16919000.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 282560.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 3275624.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 119.0
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 54.7
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 16919000.0
      }
     },
     "reported_total": true,
     "short_form": null,
     "state": "WA",
     "year": 2015
    },
    {
     "ba_code": "PSEI",
     "customer_class": "commercial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 28484000.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 28484000.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 7359000.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 130455.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 1455659.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 24.1
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 26.6
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 7359000.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 10.05
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2016
    },
    {
     "ba_code": "PSEI",
     "customer_class": "industrial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 3165000.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 3165000.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 817000.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 15160.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 171710.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 2.6
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 3.0
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 817000.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 1.13
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2016
    },
    {
     "ba_code": "PSEI",
     "customer_class": "residential",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 37869000.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 37869000.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 13256000.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 168911.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 1921607.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 29.3
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 28.6
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 13256000.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 11.29
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2016
    },
    {
     "ba_code": "PSEI",
     "customer_class": "transportation",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": "not_reported",
       "unit": "MWh",
       "value": null
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": "not_reported",
       "unit": "MWh",
       "value": null
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "other_costs_incremental_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "weighted_average_life_years": {
       "missing_reason": "not_reported",
       "unit": "years",
       "value": null
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2016
    },
    {
     "ba_code": "PSEI",
     "customer_class": "total",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 69518000.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 69518000.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 21432000.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 314526.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 3548976.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 56.0
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 58.2
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 21432000.0
      }
     },
     "reported_total": true,
     "short_form": null,
     "state": "WA",
     "year": 2016
    },
    {
     "ba_code": "PSEI",
     "customer_class": "commercial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 29818637.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 29818637.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 9321541.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 157500.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 1997634.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 25.1
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 29.1
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 9321541.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 12.7
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2017
    },
    {
     "ba_code": "PSEI",
     "customer_class": "industrial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 3313182.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 3313182.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 1035727.0000000001
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 17508.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 222002.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 4.1
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 3.2
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 1035727.0000000001
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 12.7
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2017
    },
    {
     "ba_code": "PSEI",
     "customer_class": "residential",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 37867755.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 37867755.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 19204557.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 143308.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 1707229.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 28.5
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 25.1
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 19204557.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 11.9
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2017
    },
    {
     "ba_code": "PSEI",
     "customer_class": "transportation",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": "not_reported",
       "unit": "MWh",
       "value": null
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": "not_reported",
       "unit": "MWh",
       "value": null
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "other_costs_incremental_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "weighted_average_life_years": {
       "missing_reason": "not_reported",
       "unit": "years",
       "value": null
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2017
    },
    {
     "ba_code": "PSEI",
     "customer_class": "total",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 70999574.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 70999574.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 29561825.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 318316.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 3926865.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 57.7
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 57.4
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 29561825.0
      }
     },
     "reported_total": true,
     "short_form": null,
     "state": "WA",
     "year": 2017
    },
    {
     "ba_code": "PSEI",
     "customer_class": "commercial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 30035334.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 30035334.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 6749124.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 137578.029
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 2188193.837
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 42.107
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 42.107
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 6749124.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 13.869
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2018
    },
    {
     "ba_code": "PSEI",
     "customer_class": "industrial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 3337259.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 3337259.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 749902.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 15286.447
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 243132.649
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 4.679
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 4.679
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 749902.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 1.541
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2018
    },
    {
     "ba_code": "PSEI",
     "customer_class": "residential",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 30128001.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 30128001.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 8415583.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 147053.446
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 1392005.54
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 78.186
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 78.186
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 8415583.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 10.89
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2018
    },
    {
     "ba_code": "PSEI",
     "customer_class": "transportation",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": "not_reported",
       "unit": "MWh",
       "value": null
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": "not_reported",
       "unit": "MWh",
       "value": null
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "other_costs_incremental_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "weighted_average_life_years": {
       "missing_reason": "not_reported",
       "unit": "years",
       "value": null
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2018
    },
    {
     "ba_code": "PSEI",
     "customer_class": "total",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 63500594.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 63500594.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 15914609.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 299917.922
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 3823332.026
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 124.972
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 124.972
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 15914609.0
      }
     },
     "reported_total": true,
     "short_form": null,
     "state": "WA",
     "year": 2018
    },
    {
     "ba_code": "PSEI",
     "customer_class": "commercial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 16223113.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 16223113.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 5659420.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 102432.068
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 1497249.174
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 14.753
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 14.753
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 5659420.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 15.27
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2019
    },
    {
     "ba_code": "PSEI",
     "customer_class": "industrial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 1802568.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 1802568.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 628824.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 11381.341
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 166361.019
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 1.639
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 1.639
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 628824.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 15.27
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2019
    },
    {
     "ba_code": "PSEI",
     "customer_class": "residential",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 31468951.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 31468951.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 6989987.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 139221.015
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 1612056.702
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 25.164
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 25.164
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 6989987.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 11.64
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2019
    },
    {
     "ba_code": "PSEI",
     "customer_class": "transportation",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 0.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 0.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 0.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 0.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 0.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 0.0
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 0.0
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 0.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 0.0
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2019
    },
    {
     "ba_code": "PSEI",
     "customer_class": "total",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 49494632.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 49494632.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 13278231.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 253034.424
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 3275666.895
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 41.556
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 41.556
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 13278231.0
      }
     },
     "reported_total": true,
     "short_form": null,
     "state": "WA",
     "year": 2019
    },
    {
     "ba_code": "PSEI",
     "customer_class": "commercial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 18338710.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 18338710.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 6307963.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 99535.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 1487914.181
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 13.313
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 13.313
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 6307963.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 14.95
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2020
    },
    {
     "ba_code": "PSEI",
     "customer_class": "industrial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 2037635.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 2037635.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 698614.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 11059.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 165323.798
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 1.479
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 1.479
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 698614.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 14.95
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2020
    },
    {
     "ba_code": "PSEI",
     "customer_class": "residential",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 21906262.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 21906262.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 6626155.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 109978.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 895590.328
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 22.284
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 22.284
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 6626155.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 8.5
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2020
    },
    {
     "ba_code": "PSEI",
     "customer_class": "transportation",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 0.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 0.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 0.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 0.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 0.0
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 0.0
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 0.0
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 0.0
      },
      "weighted_average_life_years": {
       "missing_reason": "not_reported",
       "unit": "years",
       "value": null
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2020
    },
    {
     "ba_code": "PSEI",
     "customer_class": "total",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 42282607.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 42282607.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 13632732.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 220572.0
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 2548828.307
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 37.076
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 37.076
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 13632732.0
      }
     },
     "reported_total": true,
     "short_form": null,
     "state": "WA",
     "year": 2020
    },
    {
     "ba_code": "PSEI",
     "customer_class": "commercial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 28967124.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 28967124.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 6946566.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 109246.512
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 1407863.624
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 15.991
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 15.991
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 6946566.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 13.32
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2021
    },
    {
     "ba_code": "PSEI",
     "customer_class": "industrial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 3253221.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 3253221.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 768543.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 12138.501
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 156429.292
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 1.777
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 1.777
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 768543.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 9.8
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2021
    },
    {
     "ba_code": "PSEI",
     "customer_class": "residential",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 21489076.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 21489076.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 6637469.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 48425.045
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 680201.093
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 12.845
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 12.845
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 6637469.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 15.726
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2021
    },
    {
     "ba_code": "PSEI",
     "customer_class": "transportation",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": "not_reported",
       "unit": "MWh",
       "value": null
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": "not_reported",
       "unit": "MWh",
       "value": null
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "other_costs_incremental_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "weighted_average_life_years": {
       "missing_reason": "not_reported",
       "unit": "years",
       "value": null
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2021
    },
    {
     "ba_code": "PSEI",
     "customer_class": "total",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 53709421.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 53709421.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 14352578.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 169810.058
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 2244494.009
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 30.613
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 30.613
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 14352578.0
      }
     },
     "reported_total": true,
     "short_form": null,
     "state": "WA",
     "year": 2021
    },
    {
     "ba_code": "PSEI",
     "customer_class": "commercial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 43536194.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 43536194.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 12469983.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 124037.741
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 1353508.788
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 12.776
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 12.776
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 12469983.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 10.46
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2022
    },
    {
     "ba_code": "PSEI",
     "customer_class": "industrial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 4837355.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 4837355.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 1385554.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 13781.971
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 150389.865
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 1.42
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 1.42
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 1385554.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 4.3
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2022
    },
    {
     "ba_code": "PSEI",
     "customer_class": "residential",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 27807908.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 27807908.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 14611301.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 105177.396
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 975638.726
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 23.383
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 23.383
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 14611301.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 2.52
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2022
    },
    {
     "ba_code": "PSEI",
     "customer_class": "transportation",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": "not_reported",
       "unit": "MWh",
       "value": null
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": "not_reported",
       "unit": "MWh",
       "value": null
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "other_costs_incremental_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "weighted_average_life_years": {
       "missing_reason": "not_reported",
       "unit": "years",
       "value": null
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2022
    },
    {
     "ba_code": "PSEI",
     "customer_class": "total",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 76181457.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 76181457.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 28466838.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 242997.108
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 2479537.379
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 37.579
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 37.579
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 28466838.0
      }
     },
     "reported_total": true,
     "short_form": null,
     "state": "WA",
     "year": 2022
    },
    {
     "ba_code": "PSEI",
     "customer_class": "commercial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 36261919.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 36261919.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 13195264.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 142634.532
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 1768897.501
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 16.41
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 16.41
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 13195264.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 12.4
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2023
    },
    {
     "ba_code": "PSEI",
     "customer_class": "industrial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 4029102.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 4029102.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 1466140.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 20143.691
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 231413.451
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 2.49
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 2.49
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 1466140.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 11.49
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2023
    },
    {
     "ba_code": "PSEI",
     "customer_class": "residential",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 31106526.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 31106526.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 14326549.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 95329.895
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 1103461.571
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 19.25
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 19.25
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 14326549.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 11.58
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2023
    },
    {
     "ba_code": "PSEI",
     "customer_class": "transportation",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": "not_reported",
       "unit": "MWh",
       "value": null
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": "not_reported",
       "unit": "MWh",
       "value": null
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "other_costs_incremental_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "weighted_average_life_years": {
       "missing_reason": "not_reported",
       "unit": "years",
       "value": null
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2023
    },
    {
     "ba_code": "PSEI",
     "customer_class": "total",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 71397547.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 71397547.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 28987953.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 258108.118
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 3103772.523
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 38.15
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 38.15
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 28987953.0
      }
     },
     "reported_total": true,
     "short_form": null,
     "state": "WA",
     "year": 2023
    },
    {
     "ba_code": "PSEI",
     "customer_class": "commercial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 48224026.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 48224026.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 12603563.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 138785.312
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 1696738.875
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 21.586
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 21.586
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 12603563.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 12.226
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2024
    },
    {
     "ba_code": "PSEI",
     "customer_class": "industrial",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 5358225.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 5358225.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 1400396.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 13169.706
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 146267.912
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 1.768
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 1.768
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 1400396.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 11.106
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2024
    },
    {
     "ba_code": "PSEI",
     "customer_class": "residential",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 42436081.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 42436081.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 10111132.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 106189.706
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 1041018.308
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 19.925
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 19.925
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 10111132.0
      },
      "weighted_average_life_years": {
       "missing_reason": null,
       "unit": "years",
       "value": 9.803
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2024
    },
    {
     "ba_code": "PSEI",
     "customer_class": "transportation",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": "not_reported",
       "unit": "MWh",
       "value": null
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": "not_reported",
       "unit": "MWh",
       "value": null
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": "not_reported",
       "unit": "MW",
       "value": null
      },
      "other_costs_incremental_cost": {
       "missing_reason": "not_reported",
       "unit": "USD",
       "value": null
      },
      "weighted_average_life_years": {
       "missing_reason": "not_reported",
       "unit": "years",
       "value": null
      }
     },
     "reported_total": false,
     "short_form": null,
     "state": "WA",
     "year": 2024
    },
    {
     "ba_code": "PSEI",
     "customer_class": "total",
     "evidence": "reported",
     "filed": true,
     "maturity": "final",
     "metrics": {
      "customer_incentives_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 96018332.0
      },
      "customer_incentives_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 96018332.0
      },
      "customer_other_costs_incremental_life_cycle_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 24115091.0
      },
      "incremental_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 258144.724
      },
      "incremental_life_cycle_energy_savings_mwh": {
       "missing_reason": null,
       "unit": "MWh",
       "value": 2884025.095
      },
      "incremental_life_cycle_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 43.279
      },
      "incremental_peak_reduction_mw": {
       "missing_reason": null,
       "unit": "MW",
       "value": 43.279
      },
      "other_costs_incremental_cost": {
       "missing_reason": null,
       "unit": "USD",
       "value": 24115091.0
      }
     },
     "reported_total": true,
     "short_form": null,
     "state": "WA",
     "year": 2024
    }
   ],
   "source_ref": "pudl-eia861-energy-efficiency",
   "years": [
    2013,
    2014,
    2015,
    2016,
    2017,
    2018,
    2019,
    2020,
    2021,
    2022,
    2023,
    2024
   ]
  },
  "note": "Programme results as each utility filed them, by customer class and report year, each in its own unit. Classes are never added into a total, years are never added into a period, and savings are never divided by sales. The one ratio shown, enrolled demand-response customers against the utility's own EIA-861 customer count for the same state, class and year, carries both counts.",
  "source_refs": [
   "pudl-eia861-energy-efficiency",
   "pudl-eia861-demand-response"
  ],
  "year": 2024
 },
 "published_lines": null,
 "release_id": "20260929T050546Z-51ae0f7d3c78",
 "reliability": {
  "available": true,
  "by_state": [
   {
    "facts": [
     {
      "basis": "EIA-861 Schedule 3 Part B line 3 or Part C line 10, Including Major Event Days: customer-minutes of sustained interruption over the report year divided by customers served, as the utility calculates and reports it for the stated state under the stated method",
      "coverage": null,
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/reliability/ieee_standard#saidi_with_med@2024",
      "label": "SAIDI, major event days included",
      "locator": "core_eia861__yearly_reliability.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; standard=ieee_standard",
      "maturity": "final",
      "method": "direct",
      "metric": "saidi_with_med",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 1,
      "quality": "valid",
      "source_ref": "pudl-reliability",
      "unit": "minutes/customer/year",
      "value": 1196.0
     },
     {
      "basis": "EIA-861 Schedule 3 Part B line 3 or Part C line 10, Excluding Major Event Days: as above with the days the utility classed as major events left out; Part B respondents determine those days under IEEE 1366, Part C respondents under their own method",
      "coverage": null,
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/reliability/ieee_standard#saidi_without_med@2024",
      "label": "SAIDI, major event days excluded",
      "locator": "core_eia861__yearly_reliability.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; standard=ieee_standard",
      "maturity": "final",
      "method": "direct",
      "metric": "saidi_without_med",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 1,
      "quality": "valid",
      "source_ref": "pudl-reliability",
      "unit": "minutes/customer/year",
      "value": 203.0
     },
     {
      "basis": "EIA-861 Schedule 3 Part B line 4: SAIDI including major event days but excluding events initiated by a loss of supply from the high-voltage system. Part B (IEEE 1366) only; Part C has no such line",
      "coverage": null,
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/reliability/ieee_standard#saidi_with_med_less_supply@2024",
      "label": "SAIDI, major event days included, loss of supply removed",
      "locator": "core_eia861__yearly_reliability.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; standard=ieee_standard",
      "maturity": "final",
      "method": "direct",
      "metric": "saidi_with_med_less_supply",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 1,
      "quality": "valid",
      "source_ref": "pudl-reliability",
      "unit": "minutes/customer/year",
      "value": 1122.0
     },
     {
      "basis": "EIA-861 Schedule 3 Part B line 5 or Part C line 11, Including Major Event Days: customers interrupted over the report year divided by customers served, as the utility calculates and reports it for the stated state under the stated method",
      "coverage": null,
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/reliability/ieee_standard#saifi_with_med@2024",
      "label": "SAIFI, major event days included",
      "locator": "core_eia861__yearly_reliability.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; standard=ieee_standard",
      "maturity": "final",
      "method": "direct",
      "metric": "saifi_with_med",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 2,
      "quality": "valid",
      "source_ref": "pudl-reliability",
      "unit": "interruptions/customer/year",
      "value": 2.2
     },
     {
      "basis": "EIA-861 Schedule 3 Part B line 5 or Part C line 11, Excluding Major Event Days",
      "coverage": null,
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/reliability/ieee_standard#saifi_without_med@2024",
      "label": "SAIFI, major event days excluded",
      "locator": "core_eia861__yearly_reliability.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; standard=ieee_standard",
      "maturity": "final",
      "method": "direct",
      "metric": "saifi_without_med",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 2,
      "quality": "valid",
      "source_ref": "pudl-reliability",
      "unit": "interruptions/customer/year",
      "value": 1.2
     },
     {
      "basis": "EIA-861 Schedule 3 Part B line 6: SAIFI including major event days but excluding events initiated by a loss of supply from the high-voltage system. Part B (IEEE 1366) only",
      "coverage": null,
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/reliability/ieee_standard#saifi_with_med_less_supply@2024",
      "label": "SAIFI, major event days included, loss of supply removed",
      "locator": "core_eia861__yearly_reliability.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; standard=ieee_standard",
      "maturity": "final",
      "method": "direct",
      "metric": "saifi_with_med_less_supply",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 2,
      "quality": "valid",
      "source_ref": "pudl-reliability",
      "unit": "interruptions/customer/year",
      "value": 2.0
     },
     {
      "basis": "Published by EIA with the Schedule 3 data as SAIDI divided by SAIFI on the same basis; the form asks the utility for SAIDI and SAIFI only. Shown as published, never recomputed here",
      "coverage": null,
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/reliability/ieee_standard#caidi_with_med@2024",
      "label": "CAIDI, major event days included",
      "locator": "core_eia861__yearly_reliability.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; standard=ieee_standard",
      "maturity": "final",
      "method": "direct",
      "metric": "caidi_with_med",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 1,
      "quality": "valid",
      "source_ref": "pudl-reliability",
      "unit": "minutes/interruption",
      "value": 543.63636
     },
     {
      "basis": "Published by EIA with the Schedule 3 data as SAIDI divided by SAIFI, both excluding major event days; not a line on the form. Shown as published, never recomputed here",
      "coverage": null,
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/reliability/ieee_standard#caidi_without_med@2024",
      "label": "CAIDI, major event days excluded",
      "locator": "core_eia861__yearly_reliability.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; standard=ieee_standard",
      "maturity": "final",
      "method": "direct",
      "metric": "caidi_without_med",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 1,
      "quality": "valid",
      "source_ref": "pudl-reliability",
      "unit": "minutes/interruption",
      "value": 169.16667
     },
     {
      "basis": "Published by EIA with the Schedule 3 Part B data as SAIDI divided by SAIFI, both with loss-of-supply events removed; not a line on the form. Shown as published, never recomputed here",
      "coverage": null,
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/reliability/ieee_standard#caidi_with_med_less_supply@2024",
      "label": "CAIDI, major event days included, loss of supply removed",
      "locator": "core_eia861__yearly_reliability.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; standard=ieee_standard",
      "maturity": "final",
      "method": "direct",
      "metric": "caidi_with_med_less_supply",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 1,
      "quality": "valid",
      "source_ref": "pudl-reliability",
      "unit": "minutes/interruption",
      "value": 561.0
     },
     {
      "basis": "EIA-861 Schedule 3 Part B line 7 or Part C line 12: total number of customers used to calculate SAIDI and SAIFI on this schedule. Under IEEE 1366 a customer is a metered service point with an active account; under another method the utility says whether inactive accounts are included. Not the retail customer count of Schedule 4",
      "coverage": null,
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/reliability/ieee_standard#reliability_customers@2024",
      "label": "Customers the indices are based on",
      "locator": "core_eia861__yearly_reliability.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; standard=ieee_standard",
      "maturity": "final",
      "method": "direct",
      "metric": "reliability_customers",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "pudl-reliability",
      "unit": "count",
      "value": 1240043.0
     },
     {
      "basis": "EIA-861 Schedule 3 Part B line 8 or Part C line 15: the highest voltage the utility considers part of its distribution system rather than the supply system; it sets which outages count as loss of supply",
      "coverage": null,
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/reliability/ieee_standard#reliability_distribution_voltage_kv@2024",
      "label": "Highest voltage counted as distribution",
      "locator": "core_eia861__yearly_reliability.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; standard=ieee_standard",
      "maturity": "final",
      "method": "direct",
      "metric": "reliability_distribution_voltage_kv",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 1,
      "quality": "valid",
      "source_ref": "pudl-reliability",
      "unit": "kV",
      "value": 34.5
     }
    ],
    "form_part": "EIA-861 Schedule 3 Part B",
    "major_event_day_basis": "Determined under IEEE 1366-2003 or IEEE 1366-2012; the form does not record which edition",
    "method": {
     "inactive_accounts_included": null,
     "momentary_interruption_definition": null,
     "momentary_interruption_label": null,
     "outages_recorded_automatically": true
    },
    "peer_groups": {
     "with_med": "aggregate:state-WA/reliability/ieee_standard/with_med",
     "without_med": "aggregate:state-WA/reliability/ieee_standard/without_med"
    },
    "standard": "ieee_standard",
    "standard_label": "IEEE 1366",
    "state": "WA"
   }
  ],
  "history": [
   {
    "caidi_with_med_less_supply_minutes": null,
    "caidi_with_med_minutes": 184.95575,
    "caidi_without_med_minutes": 144.18605,
    "customers": 1100259.0,
    "evidence": "reported",
    "form_part": "EIA-861 Schedule 3 Part B",
    "highest_distribution_voltage_kv": 35.0,
    "inactive_accounts_included": null,
    "maturity": "final",
    "momentary_interruption_definition": null,
    "momentary_interruption_label": null,
    "outages_recorded_automatically": true,
    "saidi_with_med_less_supply_minutes": null,
    "saidi_with_med_minutes": 209.0,
    "saidi_without_med_minutes": 124.0,
    "saifi_with_med_interruptions": 1.13,
    "saifi_with_med_less_supply_interruptions": null,
    "saifi_without_med_interruptions": 0.86,
    "source_ref": "pudl-reliability",
    "standard": "ieee_standard",
    "standard_label": "IEEE 1366",
    "state": "WA",
    "year": 2013
   },
   {
    "caidi_with_med_less_supply_minutes": 309.81595,
    "caidi_with_med_minutes": 293.47826,
    "caidi_without_med_minutes": 159.375,
    "customers": 1105450.0,
    "evidence": "reported",
    "form_part": "EIA-861 Schedule 3 Part B",
    "highest_distribution_voltage_kv": 35.0,
    "inactive_accounts_included": null,
    "maturity": "final",
    "momentary_interruption_definition": null,
    "momentary_interruption_label": null,
    "outages_recorded_automatically": true,
    "saidi_with_med_less_supply_minutes": 505.0,
    "saidi_with_med_minutes": 540.0,
    "saidi_without_med_minutes": 153.0,
    "saifi_with_med_interruptions": 1.84,
    "saifi_with_med_less_supply_interruptions": 1.63,
    "saifi_without_med_interruptions": 0.96,
    "source_ref": "pudl-reliability",
    "standard": "ieee_standard",
    "standard_label": "IEEE 1366",
    "state": "WA",
    "year": 2014
   },
   {
    "caidi_with_med_less_supply_minutes": 353.21637,
    "caidi_with_med_minutes": 348.62385,
    "caidi_without_med_minutes": 154.80769,
    "customers": 1114074.0,
    "evidence": "reported",
    "form_part": "EIA-861 Schedule 3 Part B",
    "highest_distribution_voltage_kv": 34.5,
    "inactive_accounts_included": null,
    "maturity": "final",
    "momentary_interruption_definition": null,
    "momentary_interruption_label": null,
    "outages_recorded_automatically": true,
    "saidi_with_med_less_supply_minutes": 604.0,
    "saidi_with_med_minutes": 760.0,
    "saidi_without_med_minutes": 161.0,
    "saifi_with_med_interruptions": 2.18,
    "saifi_with_med_less_supply_interruptions": 1.71,
    "saifi_without_med_interruptions": 1.04,
    "source_ref": "pudl-reliability",
    "standard": "ieee_standard",
    "standard_label": "IEEE 1366",
    "state": "WA",
    "year": 2015
   },
   {
    "caidi_with_med_less_supply_minutes": 250.35971,
    "caidi_with_med_minutes": 239.8773,
    "caidi_without_med_minutes": 150.98039,
    "customers": 1126181.0,
    "evidence": "reported",
    "form_part": "EIA-861 Schedule 3 Part B",
    "highest_distribution_voltage_kv": 34.5,
    "inactive_accounts_included": null,
    "maturity": "final",
    "momentary_interruption_definition": null,
    "momentary_interruption_label": null,
    "outages_recorded_automatically": true,
    "saidi_with_med_less_supply_minutes": 348.0,
    "saidi_with_med_minutes": 391.0,
    "saidi_without_med_minutes": 154.0,
    "saifi_with_med_interruptions": 1.63,
    "saifi_with_med_less_supply_interruptions": 1.39,
    "saifi_without_med_interruptions": 1.02,
    "source_ref": "pudl-reliability",
    "standard": "ieee_standard",
    "standard_label": "IEEE 1366",
    "state": "WA",
    "year": 2016
   },
   {
    "caidi_with_med_less_supply_minutes": 286.84211,
    "caidi_with_med_minutes": 265.0,
    "caidi_without_med_minutes": 156.25,
    "customers": 1137364.0,
    "evidence": "reported",
    "form_part": "EIA-861 Schedule 3 Part B",
    "highest_distribution_voltage_kv": 34.5,
    "inactive_accounts_included": null,
    "maturity": "final",
    "momentary_interruption_definition": null,
    "momentary_interruption_label": null,
    "outages_recorded_automatically": true,
    "saidi_with_med_less_supply_minutes": 436.0,
    "saidi_with_med_minutes": 477.0,
    "saidi_without_med_minutes": 175.0,
    "saifi_with_med_interruptions": 1.8,
    "saifi_with_med_less_supply_interruptions": 1.52,
    "saifi_without_med_interruptions": 1.12,
    "source_ref": "pudl-reliability",
    "standard": "ieee_standard",
    "standard_label": "IEEE 1366",
    "state": "WA",
    "year": 2017
   },
   {
    "caidi_with_med_less_supply_minutes": 306.20155,
    "caidi_with_med_minutes": 285.52632,
    "caidi_without_med_minutes": 146.46465,
    "customers": 1148866.0,
    "evidence": "reported",
    "form_part": "EIA-861 Schedule 3 Part B",
    "highest_distribution_voltage_kv": 34.5,
    "inactive_accounts_included": null,
    "maturity": "final",
    "momentary_interruption_definition": null,
    "momentary_interruption_label": null,
    "outages_recorded_automatically": true,
    "saidi_with_med_less_supply_minutes": 395.0,
    "saidi_with_med_minutes": 434.0,
    "saidi_without_med_minutes": 145.0,
    "saifi_with_med_interruptions": 1.52,
    "saifi_with_med_less_supply_interruptions": 1.29,
    "saifi_without_med_interruptions": 0.99,
    "source_ref": "pudl-reliability",
    "standard": "ieee_standard",
    "standard_label": "IEEE 1366",
    "state": "WA",
    "year": 2018
   },
   {
    "caidi_with_med_less_supply_minutes": 367.6259,
    "caidi_with_med_minutes": 350.31847,
    "caidi_without_med_minutes": 141.66667,
    "customers": 1165638.0,
    "evidence": "reported",
    "form_part": "EIA-861 Schedule 3 Part B",
    "highest_distribution_voltage_kv": 34.5,
    "inactive_accounts_included": null,
    "maturity": "final",
    "momentary_interruption_definition": null,
    "momentary_interruption_label": null,
    "outages_recorded_automatically": true,
    "saidi_with_med_less_supply_minutes": 511.0,
    "saidi_with_med_minutes": 550.0,
    "saidi_without_med_minutes": 136.0,
    "saifi_with_med_interruptions": 1.57,
    "saifi_with_med_less_supply_interruptions": 1.39,
    "saifi_without_med_interruptions": 0.96,
    "source_ref": "pudl-reliability",
    "standard": "ieee_standard",
    "standard_label": "IEEE 1366",
    "state": "WA",
    "year": 2019
   },
   {
    "caidi_with_med_less_supply_minutes": 251.00671,
    "caidi_with_med_minutes": 243.52941,
    "caidi_without_med_minutes": 161.32075,
    "customers": 1180611.0,
    "evidence": "reported",
    "form_part": "EIA-861 Schedule 3 Part B",
    "highest_distribution_voltage_kv": 34.5,
    "inactive_accounts_included": null,
    "maturity": "final",
    "momentary_interruption_definition": null,
    "momentary_interruption_label": null,
    "outages_recorded_automatically": true,
    "saidi_with_med_less_supply_minutes": 374.0,
    "saidi_with_med_minutes": 414.0,
    "saidi_without_med_minutes": 171.0,
    "saifi_with_med_interruptions": 1.7,
    "saifi_with_med_less_supply_interruptions": 1.49,
    "saifi_without_med_interruptions": 1.06,
    "source_ref": "pudl-reliability",
    "standard": "ieee_standard",
    "standard_label": "IEEE 1366",
    "state": "WA",
    "year": 2020
   },
   {
    "caidi_with_med_less_supply_minutes": 405.10204,
    "caidi_with_med_minutes": 374.00881,
    "caidi_without_med_minutes": 164.28571,
    "customers": 1192766.0,
    "evidence": "reported",
    "form_part": "EIA-861 Schedule 3 Part B",
    "highest_distribution_voltage_kv": 34.5,
    "inactive_accounts_included": null,
    "maturity": "final",
    "momentary_interruption_definition": null,
    "momentary_interruption_label": null,
    "outages_recorded_automatically": true,
    "saidi_with_med_less_supply_minutes": 794.0,
    "saidi_with_med_minutes": 849.0,
    "saidi_without_med_minutes": 207.0,
    "saifi_with_med_interruptions": 2.27,
    "saifi_with_med_less_supply_interruptions": 1.96,
    "saifi_without_med_interruptions": 1.26,
    "source_ref": "pudl-reliability",
    "standard": "ieee_standard",
    "standard_label": "IEEE 1366",
    "state": "WA",
    "year": 2021
   },
   {
    "caidi_with_med_less_supply_minutes": 282.43243,
    "caidi_with_med_minutes": 269.27711,
    "caidi_without_med_minutes": 179.81651,
    "customers": 1208346.0,
    "evidence": "reported",
    "form_part": "EIA-861 Schedule 3 Part B",
    "highest_distribution_voltage_kv": 34.5,
    "inactive_accounts_included": null,
    "maturity": "final",
    "momentary_interruption_definition": null,
    "momentary_interruption_label": null,
    "outages_recorded_automatically": true,
    "saidi_with_med_less_supply_minutes": 418.0,
    "saidi_with_med_minutes": 447.0,
    "saidi_without_med_minutes": 196.0,
    "saifi_with_med_interruptions": 1.66,
    "saifi_with_med_less_supply_interruptions": 1.48,
    "saifi_without_med_interruptions": 1.09,
    "source_ref": "pudl-reliability",
    "standard": "ieee_standard",
    "standard_label": "IEEE 1366",
    "state": "WA",
    "year": 2022
   },
   {
    "caidi_with_med_less_supply_minutes": 167.82609,
    "caidi_with_med_minutes": 156.15385,
    "caidi_without_med_minutes": 151.81818,
    "customers": 1222236.0,
    "evidence": "reported",
    "form_part": "EIA-861 Schedule 3 Part B",
    "highest_distribution_voltage_kv": 34.5,
    "inactive_accounts_included": null,
    "maturity": "final",
    "momentary_interruption_definition": null,
    "momentary_interruption_label": null,
    "outages_recorded_automatically": true,
    "saidi_with_med_less_supply_minutes": 193.0,
    "saidi_with_med_minutes": 203.0,
    "saidi_without_med_minutes": 167.0,
    "saifi_with_med_interruptions": 1.3,
    "saifi_with_med_less_supply_interruptions": 1.15,
    "saifi_without_med_interruptions": 1.1,
    "source_ref": "pudl-reliability",
    "standard": "ieee_standard",
    "standard_label": "IEEE 1366",
    "state": "WA",
    "year": 2023
   }
  ],
  "note": "Reported by the utility on EIA-861 Schedule 3 under the method it declares. IEEE 1366 and other-method figures are not comparable, and values with and without major event days answer different questions. A system average says nothing about one address. CAIDI is published by EIA as SAIDI divided by SAIFI; it is not a line on the form. A value the utility left blank stays blank.",
  "rows": [
   {
    "caidi_with_med_less_supply_minutes": 561.0,
    "caidi_with_med_minutes": 543.63636,
    "caidi_without_med_minutes": 169.16667,
    "customers": 1240043.0,
    "evidence": "reported",
    "form_part": "EIA-861 Schedule 3 Part B",
    "highest_distribution_voltage_kv": 34.5,
    "inactive_accounts_included": null,
    "maturity": "final",
    "momentary_interruption_definition": null,
    "momentary_interruption_label": null,
    "outages_recorded_automatically": true,
    "saidi_with_med_less_supply_minutes": 1122.0,
    "saidi_with_med_minutes": 1196.0,
    "saidi_without_med_minutes": 203.0,
    "saifi_with_med_interruptions": 2.2,
    "saifi_with_med_less_supply_interruptions": 2.0,
    "saifi_without_med_interruptions": 1.2,
    "source_ref": "pudl-reliability",
    "standard": "ieee_standard",
    "standard_label": "IEEE 1366",
    "state": "WA",
    "year": 2024
   }
  ],
  "source_ref": "pudl-reliability",
  "year": 2024
 },
 "retail": {
  "available": true,
  "bundled_by_class": [
   {
    "bas": [
     "PSEI"
    ],
    "customer_class": "commercial",
    "facts": [
     {
      "basis": "EIA-861 electricity sold to ultimate customers for the stated utility, state, customer class and service type; calendar year",
      "coverage": {
       "eligible": 1,
       "included": 1,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/commercial#retail_sales_mwh@2024",
      "label": "Retail sales",
      "locator": "core_eia861__yearly_sales.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; customer_class=commercial; business_model=retail; service_type=bundled",
      "maturity": "final",
      "method": "direct",
      "metric": "retail_sales_mwh",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "pudl-retail-sales",
      "unit": "MWh",
      "value": 8625073.0
     },
     {
      "basis": "EIA-861 customer count for the stated utility, state, class and service type; year-end",
      "coverage": {
       "eligible": 1,
       "included": 1,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/commercial#retail_customers@2024",
      "label": "Retail customers",
      "locator": "core_eia861__yearly_sales.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; customer_class=commercial; business_model=retail; service_type=bundled",
      "maturity": "final",
      "method": "direct",
      "metric": "retail_customers",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "pudl-retail-sales",
      "unit": "count",
      "value": 143261.0
     },
     {
      "basis": "EIA-861 revenue from electricity sold; nominal dollars of the report year",
      "coverage": {
       "eligible": 1,
       "included": 1,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/commercial#retail_revenue_usd@2024",
      "label": "Retail revenue",
      "locator": "core_eia861__yearly_sales.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; customer_class=commercial; business_model=retail; service_type=bundled",
      "maturity": "final",
      "method": "direct",
      "metric": "retail_revenue_usd",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "pudl-retail-sales",
      "unit": "USD",
      "value": 1180702100.0
     },
     {
      "basis": "revenue_usd / (sales_mwh x 10) over bundled (full-service) rows only; a realized average, not a tariff or marginal rate",
      "coverage": {
       "eligible": 1,
       "included": 1,
       "unit": "native rows with both revenue and sales"
      },
      "denominator": {
       "metric": "retail_sales_mwh",
       "rows": 1,
       "unit": "MWh",
       "value": 8625073.0
      },
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/commercial#retail_price_cents_per_kwh@2024",
      "label": "Average revenue per kWh sold",
      "locator": "core_eia861__yearly_sales.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; customer_class=commercial; business_model=retail; service_type=bundled",
      "maturity": "final",
      "method": "derived",
      "metric": "retail_price_cents_per_kwh",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 2,
      "quality": "valid",
      "source_ref": "pudl-retail-sales",
      "unit": "cents/kWh",
      "value": 13.689183848067142
     }
    ],
    "state": "WA"
   },
   {
    "bas": [
     "PSEI"
    ],
    "customer_class": "industrial",
    "facts": [
     {
      "basis": "EIA-861 electricity sold to ultimate customers for the stated utility, state, customer class and service type; calendar year",
      "coverage": {
       "eligible": 1,
       "included": 1,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/industrial#retail_sales_mwh@2024",
      "label": "Retail sales",
      "locator": "core_eia861__yearly_sales.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; customer_class=industrial; business_model=retail; service_type=bundled",
      "maturity": "final",
      "method": "direct",
      "metric": "retail_sales_mwh",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "pudl-retail-sales",
      "unit": "MWh",
      "value": 1057368.0
     },
     {
      "basis": "EIA-861 customer count for the stated utility, state, class and service type; year-end",
      "coverage": {
       "eligible": 1,
       "included": 1,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/industrial#retail_customers@2024",
      "label": "Retail customers",
      "locator": "core_eia861__yearly_sales.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; customer_class=industrial; business_model=retail; service_type=bundled",
      "maturity": "final",
      "method": "direct",
      "metric": "retail_customers",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "pudl-retail-sales",
      "unit": "count",
      "value": 3175.0
     },
     {
      "basis": "EIA-861 revenue from electricity sold; nominal dollars of the report year",
      "coverage": {
       "eligible": 1,
       "included": 1,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/industrial#retail_revenue_usd@2024",
      "label": "Retail revenue",
      "locator": "core_eia861__yearly_sales.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; customer_class=industrial; business_model=retail; service_type=bundled",
      "maturity": "final",
      "method": "direct",
      "metric": "retail_revenue_usd",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "pudl-retail-sales",
      "unit": "USD",
      "value": 131869100.0
     },
     {
      "basis": "revenue_usd / (sales_mwh x 10) over bundled (full-service) rows only; a realized average, not a tariff or marginal rate",
      "coverage": {
       "eligible": 1,
       "included": 1,
       "unit": "native rows with both revenue and sales"
      },
      "denominator": {
       "metric": "retail_sales_mwh",
       "rows": 1,
       "unit": "MWh",
       "value": 1057368.0
      },
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/industrial#retail_price_cents_per_kwh@2024",
      "label": "Average revenue per kWh sold",
      "locator": "core_eia861__yearly_sales.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; customer_class=industrial; business_model=retail; service_type=bundled",
      "maturity": "final",
      "method": "derived",
      "metric": "retail_price_cents_per_kwh",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 2,
      "quality": "valid",
      "source_ref": "pudl-retail-sales",
      "unit": "cents/kWh",
      "value": 12.47144797270203
     }
    ],
    "state": "WA"
   },
   {
    "bas": [
     "PSEI"
    ],
    "customer_class": "residential",
    "facts": [
     {
      "basis": "EIA-861 electricity sold to ultimate customers for the stated utility, state, customer class and service type; calendar year",
      "coverage": {
       "eligible": 1,
       "included": 1,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/residential#retail_sales_mwh@2024",
      "label": "Retail sales",
      "locator": "core_eia861__yearly_sales.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; customer_class=residential; business_model=retail; service_type=bundled",
      "maturity": "final",
      "method": "direct",
      "metric": "retail_sales_mwh",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "pudl-retail-sales",
      "unit": "MWh",
      "value": 11462976.0
     },
     {
      "basis": "EIA-861 customer count for the stated utility, state, class and service type; year-end",
      "coverage": {
       "eligible": 1,
       "included": 1,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/residential#retail_customers@2024",
      "label": "Retail customers",
      "locator": "core_eia861__yearly_sales.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; customer_class=residential; business_model=retail; service_type=bundled",
      "maturity": "final",
      "method": "direct",
      "metric": "retail_customers",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "pudl-retail-sales",
      "unit": "count",
      "value": 1091599.0
     },
     {
      "basis": "EIA-861 revenue from electricity sold; nominal dollars of the report year",
      "coverage": {
       "eligible": 1,
       "included": 1,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/residential#retail_revenue_usd@2024",
      "label": "Retail revenue",
      "locator": "core_eia861__yearly_sales.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; customer_class=residential; business_model=retail; service_type=bundled",
      "maturity": "final",
      "method": "direct",
      "metric": "retail_revenue_usd",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "pudl-retail-sales",
      "unit": "USD",
      "value": 1677597300.0
     },
     {
      "basis": "revenue_usd / (sales_mwh x 10) over bundled (full-service) rows only; a realized average, not a tariff or marginal rate",
      "coverage": {
       "eligible": 1,
       "included": 1,
       "unit": "native rows with both revenue and sales"
      },
      "denominator": {
       "metric": "retail_sales_mwh",
       "rows": 1,
       "unit": "MWh",
       "value": 11462976.0
      },
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/residential#retail_price_cents_per_kwh@2024",
      "label": "Average revenue per kWh sold",
      "locator": "core_eia861__yearly_sales.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; customer_class=residential; business_model=retail; service_type=bundled",
      "maturity": "final",
      "method": "derived",
      "metric": "retail_price_cents_per_kwh",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 2,
      "quality": "valid",
      "source_ref": "pudl-retail-sales",
      "unit": "cents/kWh",
      "value": 14.634919413597308
     }
    ],
    "state": "WA"
   },
   {
    "bas": [
     "PSEI"
    ],
    "customer_class": "transportation",
    "facts": [
     {
      "basis": "EIA-861 electricity sold to ultimate customers for the stated utility, state, customer class and service type; calendar year",
      "coverage": {
       "eligible": 1,
       "included": 1,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/transportation#retail_sales_mwh@2024",
      "label": "Retail sales",
      "locator": "core_eia861__yearly_sales.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; customer_class=transportation; business_model=retail; service_type=bundled",
      "maturity": "final",
      "method": "direct",
      "metric": "retail_sales_mwh",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "pudl-retail-sales",
      "unit": "MWh",
      "value": 16188.0
     },
     {
      "basis": "EIA-861 customer count for the stated utility, state, class and service type; year-end",
      "coverage": {
       "eligible": 1,
       "included": 1,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/transportation#retail_customers@2024",
      "label": "Retail customers",
      "locator": "core_eia861__yearly_sales.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; customer_class=transportation; business_model=retail; service_type=bundled",
      "maturity": "final",
      "method": "direct",
      "metric": "retail_customers",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "pudl-retail-sales",
      "unit": "count",
      "value": 1.0
     },
     {
      "basis": "EIA-861 revenue from electricity sold; nominal dollars of the report year",
      "coverage": {
       "eligible": 1,
       "included": 1,
       "unit": "native rows"
      },
      "denominator": null,
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/transportation#retail_revenue_usd@2024",
      "label": "Retail revenue",
      "locator": "core_eia861__yearly_sales.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; customer_class=transportation; business_model=retail; service_type=bundled",
      "maturity": "final",
      "method": "direct",
      "metric": "retail_revenue_usd",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 0,
      "quality": "valid",
      "source_ref": "pudl-retail-sales",
      "unit": "USD",
      "value": 2142000.0
     },
     {
      "basis": "revenue_usd / (sales_mwh x 10) over bundled (full-service) rows only; a realized average, not a tariff or marginal rate",
      "coverage": {
       "eligible": 1,
       "included": 1,
       "unit": "native rows with both revenue and sales"
      },
      "denominator": {
       "metric": "retail_sales_mwh",
       "rows": 1,
       "unit": "MWh",
       "value": 16188.0
      },
      "evidence": "reported",
      "fact_id": "org:eia:15500/WA/transportation#retail_price_cents_per_kwh@2024",
      "label": "Average revenue per kWh sold",
      "locator": "core_eia861__yearly_sales.parquet; report_date=2024-01-01; utility_id_eia=15500; state=WA; customer_class=transportation; business_model=retail; service_type=bundled",
      "maturity": "final",
      "method": "derived",
      "metric": "retail_price_cents_per_kwh",
      "missing_reason": null,
      "note": null,
      "period": {
       "hours": 8784,
       "kind": "calendar_year",
       "period_end": "2025-01-01T00:00:00Z",
       "period_start": "2024-01-01T00:00:00Z",
       "year": 2024
      },
      "precision": 2,
      "quality": "valid",
      "source_ref": "pudl-retail-sales",
      "unit": "cents/kWh",
      "value": 13.232023721275018
     }
    ],
    "state": "WA"
   }
  ],
  "filed_as": [],
  "note": "Sold to retail customers in the stated state (utility x state grain); bundled full-service rows only in the summaries; energy-only and delivery-only rows are listed but never added to bundled sales. Realized average revenue per kWh is not a tariff.",
  "rows": [
   {
    "ba": "PSEI",
    "business_model": "retail",
    "customer_class": "commercial",
    "customers": 143261,
    "evidence": "reported",
    "maturity": "final",
    "revenue_usd": 1180702100.0,
    "sales_mwh": 8625073.0,
    "service_type": "bundled",
    "short_form": null,
    "source_ref": "pudl-retail-sales",
    "state": "WA"
   },
   {
    "ba": "PSEI",
    "business_model": "retail",
    "customer_class": "commercial",
    "customers": 102,
    "evidence": "reported",
    "maturity": "final",
    "revenue_usd": 7168100.0,
    "sales_mwh": 310949.0,
    "service_type": "delivery",
    "short_form": null,
    "source_ref": "pudl-retail-sales",
    "state": "WA"
   },
   {
    "ba": "PSEI",
    "business_model": "retail",
    "customer_class": "industrial",
    "customers": 3175,
    "evidence": "reported",
    "maturity": "final",
    "revenue_usd": 131869100.0,
    "sales_mwh": 1057368.0,
    "service_type": "bundled",
    "short_form": null,
    "source_ref": "pudl-retail-sales",
    "state": "WA"
   },
   {
    "ba": "PSEI",
    "business_model": "retail",
    "customer_class": "industrial",
    "customers": 13,
    "evidence": "reported",
    "maturity": "final",
    "revenue_usd": 11461500.0,
    "sales_mwh": 1996863.0,
    "service_type": "delivery",
    "short_form": null,
    "source_ref": "pudl-retail-sales",
    "state": "WA"
   },
   {
    "ba": "PSEI",
    "business_model": "retail",
    "customer_class": "other",
    "customers": null,
    "evidence": "reported",
    "maturity": "final",
    "revenue_usd": null,
    "sales_mwh": null,
    "service_type": "bundled",
    "short_form": null,
    "source_ref": "pudl-retail-sales",
    "state": "WA"
   },
   {
    "ba": "PSEI",
    "business_model": "retail",
    "customer_class": "other",
    "customers": null,
    "evidence": "reported",
    "maturity": "final",
    "revenue_usd": null,
    "sales_mwh": null,
    "service_type": "delivery",
    "short_form": null,
    "source_ref": "pudl-retail-sales",
    "state": "WA"
   },
   {
    "ba": "PSEI",
    "business_model": "retail",
    "customer_class": "residential",
    "customers": 1091599,
    "evidence": "reported",
    "maturity": "final",
    "revenue_usd": 1677597300.0,
    "sales_mwh": 11462976.0,
    "service_type": "bundled",
    "short_form": null,
    "source_ref": "pudl-retail-sales",
    "state": "WA"
   },
   {
    "ba": "PSEI",
    "business_model": "retail",
    "customer_class": "residential",
    "customers": 0,
    "evidence": "reported",
    "maturity": "final",
    "revenue_usd": 0.0,
    "sales_mwh": 0.0,
    "service_type": "delivery",
    "short_form": null,
    "source_ref": "pudl-retail-sales",
    "state": "WA"
   },
   {
    "ba": "PSEI",
    "business_model": "retail",
    "customer_class": "transportation",
    "customers": 1,
    "evidence": "reported",
    "maturity": "final",
    "revenue_usd": 2142000.0,
    "sales_mwh": 16188.0,
    "service_type": "bundled",
    "short_form": null,
    "source_ref": "pudl-retail-sales",
    "state": "WA"
   },
   {
    "ba": "PSEI",
    "business_model": "retail",
    "customer_class": "transportation",
    "customers": 0,
    "evidence": "reported",
    "maturity": "final",
    "revenue_usd": 0.0,
    "sales_mwh": 0.0,
    "service_type": "delivery",
    "short_form": null,
    "source_ref": "pudl-retail-sales",
    "state": "WA"
   }
  ],
  "short_form_respondent": false,
  "short_form_totals": [],
  "year": 2024
 },
 "roles": {
  "operator": true,
  "owner": true,
  "retail_seller": true
 },
 "row_note": null,
 "schema_version": "1.41.0",
 "source_name": "Puget Sound Energy Inc",
 "sources": [
  "clean-energy-obligations",
  "curated-aliases",
  "pudl-eia861-demand-response",
  "pudl-eia861-energy-efficiency",
  "pudl-generators",
  "pudl-ownership",
  "pudl-reliability",
  "pudl-utilities"
 ],
 "state": "WA",
 "supply_account": {
  "available": false,
  "note": "No curated BPA supply account for this organization; absence here is the atlas's coverage, not a statement about any contract with BPA.",
  "reason": "not_curated"
 },
 "tariffs": {
  "available": true,
  "net_metering": [
   {
    "basic_charge_basis": null,
    "basic_charge_usd": null,
    "credit_rule": "Available to customers on schedules 7, 24, 25 and 29 operating a fuel cell or a hydroelectric, solar or wind generator of no more than 25 kW total capacity; the cost of the programme is collected through the schedule 83 and 150 surcharges",
    "effective_date": "2026-01-20",
    "energy_charge": null,
    "issued_date": null,
    "note": "Read from the Summary of Total Current Prices, Sheet S-27; the 25 kW cap is lower than the 100 kW the state statute allows",
    "regulator": "WA UTC (tariff WN U-60)",
    "retrieved_on": "2026-09-18",
    "riders": null,
    "schedule": "Schedule 150",
    "schedule_name": "Net Metering Services for Customer-Generator Systems",
    "source_format": "pdf",
    "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
    "state": "WA",
    "tariff_id": "pse-netmeter",
    "urdb_start_date": null,
    "urdb_uri": null
   }
  ],
  "note": "The price on the utility's own sheet on the date it was read, with the adjustment schedules it names listed beside it and never added in. It is not a bill, and it is not the realized average revenue per kWh that EIA-861 reports above: the two answer different questions.",
  "residential": [
   {
    "basic_charge_basis": "per month",
    "basic_charge_usd": 7.49,
    "bill_cases": [
     {
      "adjustment_lines": [
       {
        "amount_usd": 5.65,
        "component": "excluded",
        "name": "Electric Cons. Program Charge",
        "quantity": 600.0,
        "rate_unit": "USD/kWh",
        "rate_usd": 0.009409,
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "unit": "kWh"
       },
       {
        "amount_usd": 23.23,
        "component": "excluded",
        "name": "Power Cost Adjustment",
        "quantity": 600.0,
        "rate_unit": "USD/kWh",
        "rate_usd": 0.038719,
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "unit": "kWh"
       },
       {
        "amount_usd": -3.99,
        "component": "excluded",
        "name": "Energy Exchange Credit",
        "quantity": 600.0,
        "rate_unit": "USD/kWh",
        "rate_usd": -0.006648,
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "unit": "kWh"
       },
       {
        "amount_usd": -1.43,
        "component": "excluded",
        "name": "Other Electric Charges & Credits",
        "quantity": 600.0,
        "rate_unit": "USD/kWh",
        "rate_usd": -0.002378,
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "unit": "kWh"
       }
      ],
      "case_id": "kwh-600",
      "days": 30,
      "effective_average": {
       "basis": "Schedule charges only. The case total divided by its kWh: a computed sheet price that includes the fixed charge, not the realized average revenue per kWh that EIA-861 reports. An illustrative customer: 600 kWh over 30 days on Schedule 7 effective 2026-05-01. Not added: Electric Cons. Program Charge; Power Cost Adjustment; Energy Exchange Credit; Other Electric Charges & Credits; Effect of city tax, and any tax or adjustment the sheet does not print.",
       "coverage": null,
       "denominator": null,
       "evidence": "modeled",
       "fact_id": "org:eia:15500/tariff/pse-res-2026/kwh-600/all#bill_effective_average_cents_per_kwh",
       "label": "Computed sheet price per kWh, fixed charge included",
       "locator": "retail_tariff_components.csv; tariff_id=pse-res-2026; case=kwh-600; season=all",
       "maturity": "final",
       "method": "derived",
       "metric": "bill_effective_average_cents_per_kwh",
       "missing_reason": null,
       "note": null,
       "period": {
        "as_of": "2026-05-01",
        "kind": "instant",
        "note": "Effective date of the tariff sheet the case is priced on"
       },
       "precision": 2,
       "quality": "valid",
       "source_ref": "retail-tariffs",
       "unit": "cents/kWh",
       "value": 16.085
      },
      "exclusions": [
       {
        "basis": "per_kwh",
        "component": "excluded",
        "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, Additional Electricity Charges; PDF p. 1",
        "name": "Electric Cons. Program Charge",
        "note": "Electric Conservation Service Rider (Sch 120); the sheet's printed price, shown and not added",
        "priced_on_sheet": true,
        "rate_unit": "USD/kWh",
        "rate_usd": 0.009409,
        "reviewer": "claude-w64",
        "season": "all",
        "season_definition": null,
        "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "variant": null,
        "verified_on": "2026-09-21"
       },
       {
        "basis": "per_kwh",
        "component": "excluded",
        "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, Additional Electricity Charges; PDF p. 1",
        "name": "Power Cost Adjustment",
        "note": "Power Cost Adjustment Clause (Sch 95) and its supplemental rate; the sheet's printed price, shown and not added",
        "priced_on_sheet": true,
        "rate_unit": "USD/kWh",
        "rate_usd": 0.038719,
        "reviewer": "claude-w64",
        "season": "all",
        "season_definition": null,
        "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "variant": null,
        "verified_on": "2026-09-21"
       },
       {
        "basis": "per_kwh",
        "component": "excluded",
        "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, Additional Electricity Charges; PDF p. 1",
        "name": "Energy Exchange Credit",
        "note": "Residential and Farm Energy Exchange Benefit (Sch 194); a credit, the sheet's printed price, shown and not added",
        "priced_on_sheet": true,
        "rate_unit": "USD/kWh",
        "rate_usd": -0.006648,
        "reviewer": "claude-w64",
        "season": "all",
        "season_definition": null,
        "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "variant": null,
        "verified_on": "2026-09-21"
       },
       {
        "basis": "per_kwh",
        "component": "excluded",
        "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, Additional Electricity Charges; PDF p. 1",
        "name": "Other Electric Charges & Credits",
        "note": "Federal Wind Power Credit (Sch 95A) and Renewable Energy Credit (Sch 137); a credit, the sheet's printed price, shown and not added",
        "priced_on_sheet": true,
        "rate_unit": "USD/kWh",
        "rate_usd": -0.002378,
        "reviewer": "claude-w64",
        "season": "all",
        "season_definition": null,
        "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "variant": null,
        "verified_on": "2026-09-21"
       },
       {
        "basis": null,
        "component": "excluded",
        "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, row Effect of city tax; PDF p. 1",
        "name": "Effect of city tax",
        "note": "Varies by municipality; the sheet prints no amount. State utility tax is included in the printed charges",
        "priced_on_sheet": false,
        "rate_unit": null,
        "rate_usd": null,
        "reviewer": "claude-w64",
        "season": "all",
        "season_definition": null,
        "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "variant": null,
        "verified_on": "2026-09-21"
       }
      ],
      "kwh": 600.0,
      "lines": [
       {
        "amount_usd": 7.49,
        "component": "basic",
        "name": "Basic Charge",
        "quantity": 1.0,
        "rate_unit": "USD/month",
        "rate_usd": 7.49,
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "unit": "month"
       },
       {
        "amount_usd": 89.02,
        "component": "energy",
        "name": "Electricity Charge",
        "quantity": 600.0,
        "rate_unit": "USD/kWh",
        "rate_usd": 0.148363,
        "tier_from_kwh": 0.0,
        "tier_to_kwh": 600.0,
        "unit": "kWh"
       }
      ],
      "marginal_rate": {
       "basis": "Schedule charges only. The sheet's price for the last kWh used: the rate of the highest tier reached, summed over the sheet's per-kWh charges. An illustrative customer: 600 kWh over 30 days on Schedule 7 effective 2026-05-01. Not added: Electric Cons. Program Charge; Power Cost Adjustment; Energy Exchange Credit; Other Electric Charges & Credits; Effect of city tax, and any tax or adjustment the sheet does not print.",
       "coverage": null,
       "denominator": null,
       "evidence": "modeled",
       "fact_id": "org:eia:15500/tariff/pse-res-2026/kwh-600/all#bill_marginal_rate_usd_per_kwh",
       "label": "Sheet price of the last kWh used",
       "locator": "retail_tariff_components.csv; tariff_id=pse-res-2026; case=kwh-600; season=all",
       "maturity": "final",
       "method": "derived",
       "metric": "bill_marginal_rate_usd_per_kwh",
       "missing_reason": null,
       "note": null,
       "period": {
        "as_of": "2026-05-01",
        "kind": "instant",
        "note": "Effective date of the tariff sheet the case is priced on"
       },
       "precision": 6,
       "quality": "valid",
       "source_ref": "retail-tariffs",
       "unit": "USD/kWh",
       "value": 0.148363
      },
      "marginal_rate_with_priced_adjustments": {
       "basis": "The schedule's price for the last kWh used plus the per-kWh prices, at that kWh, among the adjustments the sheet itself prices (Electric Cons. Program Charge; Power Cost Adjustment; Energy Exchange Credit; Other Electric Charges & Credits). These are the prices printed on the sheet read on 2026-09-21; each changes on its own schedule, not with the tariff. An illustrative customer: 600 kWh over 30 days on Schedule 7 effective 2026-05-01. Still not added, because the sheet prints no price for them: Effect of city tax, and any tax or adjustment the sheet does not print.",
       "coverage": null,
       "denominator": null,
       "evidence": "modeled",
       "fact_id": "org:eia:15500/tariff/pse-res-2026/kwh-600/all#bill_marginal_rate_with_priced_adjustments_usd_per_kwh",
       "label": "Sheet price of the last kWh used, with the per-kWh adjustments the sheet prices",
       "locator": "retail_tariff_components.csv; tariff_id=pse-res-2026; case=kwh-600; season=all",
       "maturity": "final",
       "method": "derived",
       "metric": "bill_marginal_rate_with_priced_adjustments_usd_per_kwh",
       "missing_reason": null,
       "note": null,
       "period": {
        "as_of": "2026-05-01",
        "kind": "instant",
        "note": "Effective date of the tariff sheet the case is priced on"
       },
       "precision": 6,
       "quality": "valid",
       "source_ref": "retail-tariffs",
       "unit": "USD/kWh",
       "value": 0.187465
      },
      "season": "all",
      "season_definition": null,
      "total": {
       "basis": "Schedule charges only. Sum of the lines: the sheet's fixed charge plus its energy charge by tier, each line rounded to the cent. An illustrative customer: 600 kWh over 30 days on Schedule 7 effective 2026-05-01. Not added: Electric Cons. Program Charge; Power Cost Adjustment; Energy Exchange Credit; Other Electric Charges & Credits; Effect of city tax, and any tax or adjustment the sheet does not print.",
       "coverage": null,
       "denominator": null,
       "evidence": "modeled",
       "fact_id": "org:eia:15500/tariff/pse-res-2026/kwh-600/all#bill_total_usd",
       "label": "Computed bill on the published sheet",
       "locator": "retail_tariff_components.csv; tariff_id=pse-res-2026; case=kwh-600; season=all",
       "maturity": "final",
       "method": "derived",
       "metric": "bill_total_usd",
       "missing_reason": null,
       "note": null,
       "period": {
        "as_of": "2026-05-01",
        "kind": "instant",
        "note": "Effective date of the tariff sheet the case is priced on"
       },
       "precision": 2,
       "quality": "valid",
       "source_ref": "retail-tariffs",
       "unit": "USD",
       "value": 96.51
      },
      "total_with_priced_adjustments": {
       "basis": "The schedule total plus, each line rounded to the cent, the adjustments the sheet itself prices (Electric Cons. Program Charge; Power Cost Adjustment; Energy Exchange Credit; Other Electric Charges & Credits). These are the prices printed on the sheet read on 2026-09-21; each changes on its own schedule, not with the tariff. An illustrative customer: 600 kWh over 30 days on Schedule 7 effective 2026-05-01. Still not added, because the sheet prints no price for them: Effect of city tax, and any tax or adjustment the sheet does not print.",
       "coverage": null,
       "denominator": null,
       "evidence": "modeled",
       "fact_id": "org:eia:15500/tariff/pse-res-2026/kwh-600/all#bill_total_with_priced_adjustments_usd",
       "label": "Computed bill with the adjustments the sheet prices",
       "locator": "retail_tariff_components.csv; tariff_id=pse-res-2026; case=kwh-600; season=all",
       "maturity": "final",
       "method": "derived",
       "metric": "bill_total_with_priced_adjustments_usd",
       "missing_reason": null,
       "note": null,
       "period": {
        "as_of": "2026-05-01",
        "kind": "instant",
        "note": "Effective date of the tariff sheet the case is priced on"
       },
       "precision": 2,
       "quality": "valid",
       "source_ref": "retail-tariffs",
       "unit": "USD",
       "value": 119.97
      },
      "variant": null
     },
     {
      "adjustment_lines": [
       {
        "amount_usd": 8.47,
        "component": "excluded",
        "name": "Electric Cons. Program Charge",
        "quantity": 900.0,
        "rate_unit": "USD/kWh",
        "rate_usd": 0.009409,
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "unit": "kWh"
       },
       {
        "amount_usd": 34.85,
        "component": "excluded",
        "name": "Power Cost Adjustment",
        "quantity": 900.0,
        "rate_unit": "USD/kWh",
        "rate_usd": 0.038719,
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "unit": "kWh"
       },
       {
        "amount_usd": -5.98,
        "component": "excluded",
        "name": "Energy Exchange Credit",
        "quantity": 900.0,
        "rate_unit": "USD/kWh",
        "rate_usd": -0.006648,
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "unit": "kWh"
       },
       {
        "amount_usd": -2.14,
        "component": "excluded",
        "name": "Other Electric Charges & Credits",
        "quantity": 900.0,
        "rate_unit": "USD/kWh",
        "rate_usd": -0.002378,
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "unit": "kWh"
       }
      ],
      "case_id": "kwh-900",
      "days": 30,
      "effective_average": {
       "basis": "Schedule charges only. The case total divided by its kWh: a computed sheet price that includes the fixed charge, not the realized average revenue per kWh that EIA-861 reports. An illustrative customer: 900 kWh over 30 days on Schedule 7 effective 2026-05-01. Not added: Electric Cons. Program Charge; Power Cost Adjustment; Energy Exchange Credit; Other Electric Charges & Credits; Effect of city tax, and any tax or adjustment the sheet does not print.",
       "coverage": null,
       "denominator": null,
       "evidence": "modeled",
       "fact_id": "org:eia:15500/tariff/pse-res-2026/kwh-900/all#bill_effective_average_cents_per_kwh",
       "label": "Computed sheet price per kWh, fixed charge included",
       "locator": "retail_tariff_components.csv; tariff_id=pse-res-2026; case=kwh-900; season=all",
       "maturity": "final",
       "method": "derived",
       "metric": "bill_effective_average_cents_per_kwh",
       "missing_reason": null,
       "note": null,
       "period": {
        "as_of": "2026-05-01",
        "kind": "instant",
        "note": "Effective date of the tariff sheet the case is priced on"
       },
       "precision": 2,
       "quality": "valid",
       "source_ref": "retail-tariffs",
       "unit": "cents/kWh",
       "value": 16.3156
      },
      "exclusions": [
       {
        "basis": "per_kwh",
        "component": "excluded",
        "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, Additional Electricity Charges; PDF p. 1",
        "name": "Electric Cons. Program Charge",
        "note": "Electric Conservation Service Rider (Sch 120); the sheet's printed price, shown and not added",
        "priced_on_sheet": true,
        "rate_unit": "USD/kWh",
        "rate_usd": 0.009409,
        "reviewer": "claude-w64",
        "season": "all",
        "season_definition": null,
        "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "variant": null,
        "verified_on": "2026-09-21"
       },
       {
        "basis": "per_kwh",
        "component": "excluded",
        "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, Additional Electricity Charges; PDF p. 1",
        "name": "Power Cost Adjustment",
        "note": "Power Cost Adjustment Clause (Sch 95) and its supplemental rate; the sheet's printed price, shown and not added",
        "priced_on_sheet": true,
        "rate_unit": "USD/kWh",
        "rate_usd": 0.038719,
        "reviewer": "claude-w64",
        "season": "all",
        "season_definition": null,
        "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "variant": null,
        "verified_on": "2026-09-21"
       },
       {
        "basis": "per_kwh",
        "component": "excluded",
        "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, Additional Electricity Charges; PDF p. 1",
        "name": "Energy Exchange Credit",
        "note": "Residential and Farm Energy Exchange Benefit (Sch 194); a credit, the sheet's printed price, shown and not added",
        "priced_on_sheet": true,
        "rate_unit": "USD/kWh",
        "rate_usd": -0.006648,
        "reviewer": "claude-w64",
        "season": "all",
        "season_definition": null,
        "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "variant": null,
        "verified_on": "2026-09-21"
       },
       {
        "basis": "per_kwh",
        "component": "excluded",
        "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, Additional Electricity Charges; PDF p. 1",
        "name": "Other Electric Charges & Credits",
        "note": "Federal Wind Power Credit (Sch 95A) and Renewable Energy Credit (Sch 137); a credit, the sheet's printed price, shown and not added",
        "priced_on_sheet": true,
        "rate_unit": "USD/kWh",
        "rate_usd": -0.002378,
        "reviewer": "claude-w64",
        "season": "all",
        "season_definition": null,
        "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "variant": null,
        "verified_on": "2026-09-21"
       },
       {
        "basis": null,
        "component": "excluded",
        "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, row Effect of city tax; PDF p. 1",
        "name": "Effect of city tax",
        "note": "Varies by municipality; the sheet prints no amount. State utility tax is included in the printed charges",
        "priced_on_sheet": false,
        "rate_unit": null,
        "rate_usd": null,
        "reviewer": "claude-w64",
        "season": "all",
        "season_definition": null,
        "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "variant": null,
        "verified_on": "2026-09-21"
       }
      ],
      "kwh": 900.0,
      "lines": [
       {
        "amount_usd": 7.49,
        "component": "basic",
        "name": "Basic Charge",
        "quantity": 1.0,
        "rate_unit": "USD/month",
        "rate_usd": 7.49,
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "unit": "month"
       },
       {
        "amount_usd": 89.02,
        "component": "energy",
        "name": "Electricity Charge",
        "quantity": 600.0,
        "rate_unit": "USD/kWh",
        "rate_usd": 0.148363,
        "tier_from_kwh": 0.0,
        "tier_to_kwh": 600.0,
        "unit": "kWh"
       },
       {
        "amount_usd": 50.33,
        "component": "energy",
        "name": "Electricity Charge",
        "quantity": 300.0,
        "rate_unit": "USD/kWh",
        "rate_usd": 0.16778,
        "tier_from_kwh": 600.0,
        "tier_to_kwh": null,
        "unit": "kWh"
       }
      ],
      "marginal_rate": {
       "basis": "Schedule charges only. The sheet's price for the last kWh used: the rate of the highest tier reached, summed over the sheet's per-kWh charges. An illustrative customer: 900 kWh over 30 days on Schedule 7 effective 2026-05-01. Not added: Electric Cons. Program Charge; Power Cost Adjustment; Energy Exchange Credit; Other Electric Charges & Credits; Effect of city tax, and any tax or adjustment the sheet does not print.",
       "coverage": null,
       "denominator": null,
       "evidence": "modeled",
       "fact_id": "org:eia:15500/tariff/pse-res-2026/kwh-900/all#bill_marginal_rate_usd_per_kwh",
       "label": "Sheet price of the last kWh used",
       "locator": "retail_tariff_components.csv; tariff_id=pse-res-2026; case=kwh-900; season=all",
       "maturity": "final",
       "method": "derived",
       "metric": "bill_marginal_rate_usd_per_kwh",
       "missing_reason": null,
       "note": null,
       "period": {
        "as_of": "2026-05-01",
        "kind": "instant",
        "note": "Effective date of the tariff sheet the case is priced on"
       },
       "precision": 6,
       "quality": "valid",
       "source_ref": "retail-tariffs",
       "unit": "USD/kWh",
       "value": 0.16778
      },
      "marginal_rate_with_priced_adjustments": {
       "basis": "The schedule's price for the last kWh used plus the per-kWh prices, at that kWh, among the adjustments the sheet itself prices (Electric Cons. Program Charge; Power Cost Adjustment; Energy Exchange Credit; Other Electric Charges & Credits). These are the prices printed on the sheet read on 2026-09-21; each changes on its own schedule, not with the tariff. An illustrative customer: 900 kWh over 30 days on Schedule 7 effective 2026-05-01. Still not added, because the sheet prints no price for them: Effect of city tax, and any tax or adjustment the sheet does not print.",
       "coverage": null,
       "denominator": null,
       "evidence": "modeled",
       "fact_id": "org:eia:15500/tariff/pse-res-2026/kwh-900/all#bill_marginal_rate_with_priced_adjustments_usd_per_kwh",
       "label": "Sheet price of the last kWh used, with the per-kWh adjustments the sheet prices",
       "locator": "retail_tariff_components.csv; tariff_id=pse-res-2026; case=kwh-900; season=all",
       "maturity": "final",
       "method": "derived",
       "metric": "bill_marginal_rate_with_priced_adjustments_usd_per_kwh",
       "missing_reason": null,
       "note": null,
       "period": {
        "as_of": "2026-05-01",
        "kind": "instant",
        "note": "Effective date of the tariff sheet the case is priced on"
       },
       "precision": 6,
       "quality": "valid",
       "source_ref": "retail-tariffs",
       "unit": "USD/kWh",
       "value": 0.206882
      },
      "season": "all",
      "season_definition": null,
      "total": {
       "basis": "Schedule charges only. Sum of the lines: the sheet's fixed charge plus its energy charge by tier, each line rounded to the cent. An illustrative customer: 900 kWh over 30 days on Schedule 7 effective 2026-05-01. Not added: Electric Cons. Program Charge; Power Cost Adjustment; Energy Exchange Credit; Other Electric Charges & Credits; Effect of city tax, and any tax or adjustment the sheet does not print.",
       "coverage": null,
       "denominator": null,
       "evidence": "modeled",
       "fact_id": "org:eia:15500/tariff/pse-res-2026/kwh-900/all#bill_total_usd",
       "label": "Computed bill on the published sheet",
       "locator": "retail_tariff_components.csv; tariff_id=pse-res-2026; case=kwh-900; season=all",
       "maturity": "final",
       "method": "derived",
       "metric": "bill_total_usd",
       "missing_reason": null,
       "note": null,
       "period": {
        "as_of": "2026-05-01",
        "kind": "instant",
        "note": "Effective date of the tariff sheet the case is priced on"
       },
       "precision": 2,
       "quality": "valid",
       "source_ref": "retail-tariffs",
       "unit": "USD",
       "value": 146.84
      },
      "total_with_priced_adjustments": {
       "basis": "The schedule total plus, each line rounded to the cent, the adjustments the sheet itself prices (Electric Cons. Program Charge; Power Cost Adjustment; Energy Exchange Credit; Other Electric Charges & Credits). These are the prices printed on the sheet read on 2026-09-21; each changes on its own schedule, not with the tariff. An illustrative customer: 900 kWh over 30 days on Schedule 7 effective 2026-05-01. Still not added, because the sheet prints no price for them: Effect of city tax, and any tax or adjustment the sheet does not print.",
       "coverage": null,
       "denominator": null,
       "evidence": "modeled",
       "fact_id": "org:eia:15500/tariff/pse-res-2026/kwh-900/all#bill_total_with_priced_adjustments_usd",
       "label": "Computed bill with the adjustments the sheet prices",
       "locator": "retail_tariff_components.csv; tariff_id=pse-res-2026; case=kwh-900; season=all",
       "maturity": "final",
       "method": "derived",
       "metric": "bill_total_with_priced_adjustments_usd",
       "missing_reason": null,
       "note": null,
       "period": {
        "as_of": "2026-05-01",
        "kind": "instant",
        "note": "Effective date of the tariff sheet the case is priced on"
       },
       "precision": 2,
       "quality": "valid",
       "source_ref": "retail-tariffs",
       "unit": "USD",
       "value": 182.04
      },
      "variant": null
     },
     {
      "adjustment_lines": [
       {
        "amount_usd": 11.29,
        "component": "excluded",
        "name": "Electric Cons. Program Charge",
        "quantity": 1200.0,
        "rate_unit": "USD/kWh",
        "rate_usd": 0.009409,
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "unit": "kWh"
       },
       {
        "amount_usd": 46.46,
        "component": "excluded",
        "name": "Power Cost Adjustment",
        "quantity": 1200.0,
        "rate_unit": "USD/kWh",
        "rate_usd": 0.038719,
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "unit": "kWh"
       },
       {
        "amount_usd": -7.98,
        "component": "excluded",
        "name": "Energy Exchange Credit",
        "quantity": 1200.0,
        "rate_unit": "USD/kWh",
        "rate_usd": -0.006648,
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "unit": "kWh"
       },
       {
        "amount_usd": -2.85,
        "component": "excluded",
        "name": "Other Electric Charges & Credits",
        "quantity": 1200.0,
        "rate_unit": "USD/kWh",
        "rate_usd": -0.002378,
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "unit": "kWh"
       }
      ],
      "case_id": "kwh-1200",
      "days": 30,
      "effective_average": {
       "basis": "Schedule charges only. The case total divided by its kWh: a computed sheet price that includes the fixed charge, not the realized average revenue per kWh that EIA-861 reports. An illustrative customer: 1200 kWh over 30 days on Schedule 7 effective 2026-05-01. Not added: Electric Cons. Program Charge; Power Cost Adjustment; Energy Exchange Credit; Other Electric Charges & Credits; Effect of city tax, and any tax or adjustment the sheet does not print.",
       "coverage": null,
       "denominator": null,
       "evidence": "modeled",
       "fact_id": "org:eia:15500/tariff/pse-res-2026/kwh-1200/all#bill_effective_average_cents_per_kwh",
       "label": "Computed sheet price per kWh, fixed charge included",
       "locator": "retail_tariff_components.csv; tariff_id=pse-res-2026; case=kwh-1200; season=all",
       "maturity": "final",
       "method": "derived",
       "metric": "bill_effective_average_cents_per_kwh",
       "missing_reason": null,
       "note": null,
       "period": {
        "as_of": "2026-05-01",
        "kind": "instant",
        "note": "Effective date of the tariff sheet the case is priced on"
       },
       "precision": 2,
       "quality": "valid",
       "source_ref": "retail-tariffs",
       "unit": "cents/kWh",
       "value": 16.4317
      },
      "exclusions": [
       {
        "basis": "per_kwh",
        "component": "excluded",
        "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, Additional Electricity Charges; PDF p. 1",
        "name": "Electric Cons. Program Charge",
        "note": "Electric Conservation Service Rider (Sch 120); the sheet's printed price, shown and not added",
        "priced_on_sheet": true,
        "rate_unit": "USD/kWh",
        "rate_usd": 0.009409,
        "reviewer": "claude-w64",
        "season": "all",
        "season_definition": null,
        "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "variant": null,
        "verified_on": "2026-09-21"
       },
       {
        "basis": "per_kwh",
        "component": "excluded",
        "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, Additional Electricity Charges; PDF p. 1",
        "name": "Power Cost Adjustment",
        "note": "Power Cost Adjustment Clause (Sch 95) and its supplemental rate; the sheet's printed price, shown and not added",
        "priced_on_sheet": true,
        "rate_unit": "USD/kWh",
        "rate_usd": 0.038719,
        "reviewer": "claude-w64",
        "season": "all",
        "season_definition": null,
        "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "variant": null,
        "verified_on": "2026-09-21"
       },
       {
        "basis": "per_kwh",
        "component": "excluded",
        "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, Additional Electricity Charges; PDF p. 1",
        "name": "Energy Exchange Credit",
        "note": "Residential and Farm Energy Exchange Benefit (Sch 194); a credit, the sheet's printed price, shown and not added",
        "priced_on_sheet": true,
        "rate_unit": "USD/kWh",
        "rate_usd": -0.006648,
        "reviewer": "claude-w64",
        "season": "all",
        "season_definition": null,
        "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "variant": null,
        "verified_on": "2026-09-21"
       },
       {
        "basis": "per_kwh",
        "component": "excluded",
        "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, Additional Electricity Charges; PDF p. 1",
        "name": "Other Electric Charges & Credits",
        "note": "Federal Wind Power Credit (Sch 95A) and Renewable Energy Credit (Sch 137); a credit, the sheet's printed price, shown and not added",
        "priced_on_sheet": true,
        "rate_unit": "USD/kWh",
        "rate_usd": -0.002378,
        "reviewer": "claude-w64",
        "season": "all",
        "season_definition": null,
        "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "variant": null,
        "verified_on": "2026-09-21"
       },
       {
        "basis": null,
        "component": "excluded",
        "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, row Effect of city tax; PDF p. 1",
        "name": "Effect of city tax",
        "note": "Varies by municipality; the sheet prints no amount. State utility tax is included in the printed charges",
        "priced_on_sheet": false,
        "rate_unit": null,
        "rate_usd": null,
        "reviewer": "claude-w64",
        "season": "all",
        "season_definition": null,
        "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "variant": null,
        "verified_on": "2026-09-21"
       }
      ],
      "kwh": 1200.0,
      "lines": [
       {
        "amount_usd": 7.49,
        "component": "basic",
        "name": "Basic Charge",
        "quantity": 1.0,
        "rate_unit": "USD/month",
        "rate_usd": 7.49,
        "tier_from_kwh": null,
        "tier_to_kwh": null,
        "unit": "month"
       },
       {
        "amount_usd": 89.02,
        "component": "energy",
        "name": "Electricity Charge",
        "quantity": 600.0,
        "rate_unit": "USD/kWh",
        "rate_usd": 0.148363,
        "tier_from_kwh": 0.0,
        "tier_to_kwh": 600.0,
        "unit": "kWh"
       },
       {
        "amount_usd": 100.67,
        "component": "energy",
        "name": "Electricity Charge",
        "quantity": 600.0,
        "rate_unit": "USD/kWh",
        "rate_usd": 0.16778,
        "tier_from_kwh": 600.0,
        "tier_to_kwh": null,
        "unit": "kWh"
       }
      ],
      "marginal_rate": {
       "basis": "Schedule charges only. The sheet's price for the last kWh used: the rate of the highest tier reached, summed over the sheet's per-kWh charges. An illustrative customer: 1200 kWh over 30 days on Schedule 7 effective 2026-05-01. Not added: Electric Cons. Program Charge; Power Cost Adjustment; Energy Exchange Credit; Other Electric Charges & Credits; Effect of city tax, and any tax or adjustment the sheet does not print.",
       "coverage": null,
       "denominator": null,
       "evidence": "modeled",
       "fact_id": "org:eia:15500/tariff/pse-res-2026/kwh-1200/all#bill_marginal_rate_usd_per_kwh",
       "label": "Sheet price of the last kWh used",
       "locator": "retail_tariff_components.csv; tariff_id=pse-res-2026; case=kwh-1200; season=all",
       "maturity": "final",
       "method": "derived",
       "metric": "bill_marginal_rate_usd_per_kwh",
       "missing_reason": null,
       "note": null,
       "period": {
        "as_of": "2026-05-01",
        "kind": "instant",
        "note": "Effective date of the tariff sheet the case is priced on"
       },
       "precision": 6,
       "quality": "valid",
       "source_ref": "retail-tariffs",
       "unit": "USD/kWh",
       "value": 0.16778
      },
      "marginal_rate_with_priced_adjustments": {
       "basis": "The schedule's price for the last kWh used plus the per-kWh prices, at that kWh, among the adjustments the sheet itself prices (Electric Cons. Program Charge; Power Cost Adjustment; Energy Exchange Credit; Other Electric Charges & Credits). These are the prices printed on the sheet read on 2026-09-21; each changes on its own schedule, not with the tariff. An illustrative customer: 1200 kWh over 30 days on Schedule 7 effective 2026-05-01. Still not added, because the sheet prints no price for them: Effect of city tax, and any tax or adjustment the sheet does not print.",
       "coverage": null,
       "denominator": null,
       "evidence": "modeled",
       "fact_id": "org:eia:15500/tariff/pse-res-2026/kwh-1200/all#bill_marginal_rate_with_priced_adjustments_usd_per_kwh",
       "label": "Sheet price of the last kWh used, with the per-kWh adjustments the sheet prices",
       "locator": "retail_tariff_components.csv; tariff_id=pse-res-2026; case=kwh-1200; season=all",
       "maturity": "final",
       "method": "derived",
       "metric": "bill_marginal_rate_with_priced_adjustments_usd_per_kwh",
       "missing_reason": null,
       "note": null,
       "period": {
        "as_of": "2026-05-01",
        "kind": "instant",
        "note": "Effective date of the tariff sheet the case is priced on"
       },
       "precision": 6,
       "quality": "valid",
       "source_ref": "retail-tariffs",
       "unit": "USD/kWh",
       "value": 0.206882
      },
      "season": "all",
      "season_definition": null,
      "total": {
       "basis": "Schedule charges only. Sum of the lines: the sheet's fixed charge plus its energy charge by tier, each line rounded to the cent. An illustrative customer: 1200 kWh over 30 days on Schedule 7 effective 2026-05-01. Not added: Electric Cons. Program Charge; Power Cost Adjustment; Energy Exchange Credit; Other Electric Charges & Credits; Effect of city tax, and any tax or adjustment the sheet does not print.",
       "coverage": null,
       "denominator": null,
       "evidence": "modeled",
       "fact_id": "org:eia:15500/tariff/pse-res-2026/kwh-1200/all#bill_total_usd",
       "label": "Computed bill on the published sheet",
       "locator": "retail_tariff_components.csv; tariff_id=pse-res-2026; case=kwh-1200; season=all",
       "maturity": "final",
       "method": "derived",
       "metric": "bill_total_usd",
       "missing_reason": null,
       "note": null,
       "period": {
        "as_of": "2026-05-01",
        "kind": "instant",
        "note": "Effective date of the tariff sheet the case is priced on"
       },
       "precision": 2,
       "quality": "valid",
       "source_ref": "retail-tariffs",
       "unit": "USD",
       "value": 197.18
      },
      "total_with_priced_adjustments": {
       "basis": "The schedule total plus, each line rounded to the cent, the adjustments the sheet itself prices (Electric Cons. Program Charge; Power Cost Adjustment; Energy Exchange Credit; Other Electric Charges & Credits). These are the prices printed on the sheet read on 2026-09-21; each changes on its own schedule, not with the tariff. An illustrative customer: 1200 kWh over 30 days on Schedule 7 effective 2026-05-01. Still not added, because the sheet prints no price for them: Effect of city tax, and any tax or adjustment the sheet does not print.",
       "coverage": null,
       "denominator": null,
       "evidence": "modeled",
       "fact_id": "org:eia:15500/tariff/pse-res-2026/kwh-1200/all#bill_total_with_priced_adjustments_usd",
       "label": "Computed bill with the adjustments the sheet prices",
       "locator": "retail_tariff_components.csv; tariff_id=pse-res-2026; case=kwh-1200; season=all",
       "maturity": "final",
       "method": "derived",
       "metric": "bill_total_with_priced_adjustments_usd",
       "missing_reason": null,
       "note": null,
       "period": {
        "as_of": "2026-05-01",
        "kind": "instant",
        "note": "Effective date of the tariff sheet the case is priced on"
       },
       "precision": 2,
       "quality": "valid",
       "source_ref": "retail-tariffs",
       "unit": "USD",
       "value": 244.1
      },
      "variant": null
     }
    ],
    "components": [
     {
      "basis": "per_month",
      "component": "basic",
      "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, row Basic Charge; PDF p. 1",
      "name": "Basic Charge",
      "note": "Printed as 7.49 (per month) in an example that assumes 30 days of service; the sheet states no proration",
      "rate_unit": "USD/month",
      "rate_usd": 7.49,
      "reviewer": "claude-w64",
      "season": "all",
      "season_definition": null,
      "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
      "tier_from_kwh": null,
      "tier_to_kwh": null,
      "variant": null,
      "verified_on": "2026-09-21"
     },
     {
      "basis": "per_kwh",
      "component": "energy",
      "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, row Tier 1 (per kWh for the first 600 kWh); PDF p. 1",
      "name": "Electricity Charge",
      "note": "The sheet's Electricity Charge is one price that bundles the Schedule 7 energy charge with schedules 111, 129, 129D, 140, 141A, 141CEI, 141COL, 141N, 141PFG, 141R, 141TEP, 141TEX, 141WFP, 141Z and 142; it prints no separate Schedule 7 price",
      "rate_unit": "USD/kWh",
      "rate_usd": 0.148363,
      "reviewer": "claude-w64",
      "season": "all",
      "season_definition": null,
      "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
      "tier_from_kwh": 0.0,
      "tier_to_kwh": 600.0,
      "variant": null,
      "verified_on": "2026-09-21"
     },
     {
      "basis": "per_kwh",
      "component": "energy",
      "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, row Tier 2 (per kWh for all over 600 kWh); PDF p. 1",
      "name": "Electricity Charge",
      "note": "The sheet's Electricity Charge is one price that bundles the Schedule 7 energy charge with schedules 111, 129, 129D, 140, 141A, 141CEI, 141COL, 141N, 141PFG, 141R, 141TEP, 141TEX, 141WFP, 141Z and 142; it prints no separate Schedule 7 price",
      "rate_unit": "USD/kWh",
      "rate_usd": 0.16778,
      "reviewer": "claude-w64",
      "season": "all",
      "season_definition": null,
      "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
      "tier_from_kwh": 600.0,
      "tier_to_kwh": null,
      "variant": null,
      "verified_on": "2026-09-21"
     }
    ],
    "components_missing_note": null,
    "components_missing_reason": null,
    "credit_rule": null,
    "effective_date": "2026-05-01",
    "energy_charge": "0.148363 USD/kWh first 600 kWh; 0.167780 above; plus electric conservation 0.009409, power cost adjustment 0.038719, energy exchange credit -0.006648, other -0.002378",
    "exclusions": [
     {
      "basis": "per_kwh",
      "component": "excluded",
      "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, Additional Electricity Charges; PDF p. 1",
      "name": "Electric Cons. Program Charge",
      "note": "Electric Conservation Service Rider (Sch 120); the sheet's printed price, shown and not added",
      "priced_on_sheet": true,
      "rate_unit": "USD/kWh",
      "rate_usd": 0.009409,
      "reviewer": "claude-w64",
      "season": "all",
      "season_definition": null,
      "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
      "tier_from_kwh": null,
      "tier_to_kwh": null,
      "variant": null,
      "verified_on": "2026-09-21"
     },
     {
      "basis": "per_kwh",
      "component": "excluded",
      "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, Additional Electricity Charges; PDF p. 1",
      "name": "Power Cost Adjustment",
      "note": "Power Cost Adjustment Clause (Sch 95) and its supplemental rate; the sheet's printed price, shown and not added",
      "priced_on_sheet": true,
      "rate_unit": "USD/kWh",
      "rate_usd": 0.038719,
      "reviewer": "claude-w64",
      "season": "all",
      "season_definition": null,
      "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
      "tier_from_kwh": null,
      "tier_to_kwh": null,
      "variant": null,
      "verified_on": "2026-09-21"
     },
     {
      "basis": "per_kwh",
      "component": "excluded",
      "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, Additional Electricity Charges; PDF p. 1",
      "name": "Energy Exchange Credit",
      "note": "Residential and Farm Energy Exchange Benefit (Sch 194); a credit, the sheet's printed price, shown and not added",
      "priced_on_sheet": true,
      "rate_unit": "USD/kWh",
      "rate_usd": -0.006648,
      "reviewer": "claude-w64",
      "season": "all",
      "season_definition": null,
      "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
      "tier_from_kwh": null,
      "tier_to_kwh": null,
      "variant": null,
      "verified_on": "2026-09-21"
     },
     {
      "basis": "per_kwh",
      "component": "excluded",
      "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, Additional Electricity Charges; PDF p. 1",
      "name": "Other Electric Charges & Credits",
      "note": "Federal Wind Power Credit (Sch 95A) and Renewable Energy Credit (Sch 137); a credit, the sheet's printed price, shown and not added",
      "priced_on_sheet": true,
      "rate_unit": "USD/kWh",
      "rate_usd": -0.002378,
      "reviewer": "claude-w64",
      "season": "all",
      "season_definition": null,
      "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
      "tier_from_kwh": null,
      "tier_to_kwh": null,
      "variant": null,
      "verified_on": "2026-09-21"
     },
     {
      "basis": null,
      "component": "excluded",
      "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, row Effect of city tax; PDF p. 1",
      "name": "Effect of city tax",
      "note": "Varies by municipality; the sheet prints no amount. State utility tax is included in the printed charges",
      "priced_on_sheet": false,
      "rate_unit": null,
      "rate_usd": null,
      "reviewer": "claude-w64",
      "season": "all",
      "season_definition": null,
      "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
      "tier_from_kwh": null,
      "tier_to_kwh": null,
      "variant": null,
      "verified_on": "2026-09-21"
     }
    ],
    "issued_date": null,
    "note": "Summary of Total Current Prices, Sheet S-1; an 800 kWh example bill on the same sheet is 161.36 USD",
    "regulator": "WA UTC (tariff WN U-60)",
    "retrieved_on": "2026-09-18",
    "riders": "tier prices bundle schedules 7, 111 (cap-and-invest), 129, 140, the 141 series and 142",
    "schedule": "Schedule 7",
    "schedule_name": "Residential Service",
    "sheet_examples": [
     {
      "computed_basis": "with_priced_adjustments",
      "computed_total_usd": 161.36,
      "days": 30,
      "difference_usd": 0.0,
      "kwh": 800.0,
      "locator": "Electric Summary Sheet No. S-1, SCH 7 Residential Service, For a customer who used 800 kWh during one month (assuming 30 days of service), row TOTAL BILL; PDF p. 1",
      "printed_total_usd": 161.36,
      "season": "all",
      "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
      "tolerance_usd": 0.05,
      "variant": null,
      "verified_on": "2026-09-21",
      "within_tolerance": true
     }
    ],
    "source_format": "pdf",
    "source_url": "https://www.pse.com/-/media/Project/PSE/Portal/Rate-documents/summ_elec_prices_2026_05_01.pdf",
    "state": "WA",
    "tariff_id": "pse-res-2026",
    "urdb_start_date": "2026-03-21",
    "urdb_uri": "https://apps.openei.org/IURDB/rate/view/69efcb2f99dfb306b5"
   }
  ],
  "source_ref": "retail-tariffs",
  "utility_name": "Puget Sound Energy"
 },
 "territories": [
  {
   "id": "territory:waecy:53",
   "name": "Puget Sound Energy",
   "relation": "reviewed",
   "source_ref": "wa-ecology-territories"
  }
 ],
 "type": "org",