Wheatridge Hybrid

Entity plant:eia:62745 · release 20260929T050546Z-51ae0f7d3c78 · schema 1.41.0. Immutable citation page; values as published in this release. Current pages may be newer.

FactValueUnitPeriodEvidence / methodQualitySource and locator
Nameplate capacity, operating generators280.0MW2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=62745
Generators listed3count2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=62745
Operating generators3count2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=62745
Storage discharge capacity, operating storage units30.0MW2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=62745
Net generation738,218MWh2024reported / derivedvalidpudl-output
out_eia923__yearly_generation_fuel_combined.parquet; report_date=2024-01-01; plant_id_eia=62745
Capacity factor0.300fraction2024reported / derivedvalidpudl-output
derived: net_generation_mwh@2024 / (nameplate_mw_op x 8784 h)
Nameplate capacity30.0MW2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=62745; generator_id=BTRY
Net summer capacity30.0MW2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=62745; generator_id=BTRY
Net winter capacity30.0MW2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=62745; generator_id=BTRY
Energy storage capacity120.0MWh2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=62745; generator_id=BTRY
Maximum charge rate30.0MW2024reported / derivedvalidpudl-storage-generators
core_eia860__scd_generators_energy_storage.parquet; report_date=2024-01-01; plant_id_eia=62745; generator_id=BTRY
Storage duration at full discharge4.0h2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=62745; generator_id=BTRY
Nameplate capacity50.0MW2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=62745; generator_id=SOLAR
Net summer capacity50.0MW2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=62745; generator_id=SOLAR
Net winter capacity50.0MW2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=62745; generator_id=SOLAR
Nameplate capacity200.0MW2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=62745; generator_id=WIND
Net summer capacity200.0MW2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=62745; generator_id=WIND
Net winter capacity200.0MW2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=62745; generator_id=WIND
Storage charge capacity, operating storage units30.0MW2024reported / derivedvalidpudl-storage-generators
core_eia860__scd_generators_energy_storage.parquet; report_date=2024-01-01; plant_id_eia=62745
Storage energy capacity, operating storage units120.0MWh2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=62745
Storage duration at full discharge4.0h2024reported / derivedvalidpudl-generators
derived: validated per-unit ratings; plant_id_eia=62745
Energy taken to charge40,259MWh2024reported / derivedvalidpudl-storage-operation-monthly
core_eia923__monthly_energy_storage.parquet; report_date=2024; plant_id_eia=62745; prime_mover_code=storage prime movers
Energy discharged28,254MWh2024reported / derivedvalidpudl-storage-operation-monthly
core_eia923__monthly_energy_storage.parquet; report_date=2024; plant_id_eia=62745; prime_mover_code=storage prime movers
Net storage output-12,002MWh2024reported / derivedvalidpudl-storage-operation-monthly
core_eia923__monthly_energy_storage.parquet; report_date=2024; plant_id_eia=62745; prime_mover_code=storage prime movers
Implied round-trip ratio0.702fraction2024reported / derivedvalidpudl-storage-operation-monthly
core_eia923__monthly_energy_storage.parquet; report_date=2024; plant_id_eia=62745; prime_mover_code=storage prime movers
Energy taken to charge18,621MWh2022reported / derivedsuspectpudl-storage-operation-monthly
core_eia923__monthly_energy_storage.parquet; report_date=2022; plant_id_eia=62745; prime_mover_code=storage prime movers
Energy discharged17,820MWh2022reported / derivedsuspectpudl-storage-operation-monthly
core_eia923__monthly_energy_storage.parquet; report_date=2022; plant_id_eia=62745; prime_mover_code=storage prime movers
Net storage output-801MWh2022reported / derivedsuspectpudl-storage-operation-monthly
core_eia923__monthly_energy_storage.parquet; report_date=2022; plant_id_eia=62745; prime_mover_code=storage prime movers
Implied round-trip ratio—fraction2022reported / derivedunsupported (unsupported)pudl-storage-operation-monthly
core_eia923__monthly_energy_storage.parquet; report_date=2022; plant_id_eia=62745; prime_mover_code=storage prime movers
Energy taken to charge28,532MWh2023reported / derivedvalidpudl-storage-operation-monthly
core_eia923__monthly_energy_storage.parquet; report_date=2023; plant_id_eia=62745; prime_mover_code=storage prime movers
Energy discharged24,018MWh2023reported / derivedvalidpudl-storage-operation-monthly
core_eia923__monthly_energy_storage.parquet; report_date=2023; plant_id_eia=62745; prime_mover_code=storage prime movers
Net storage output-3,224MWh2023reported / derivedvalidpudl-storage-operation-monthly
core_eia923__monthly_energy_storage.parquet; report_date=2023; plant_id_eia=62745; prime_mover_code=storage prime movers
Implied round-trip ratio0.842fraction2023reported / derivedvalidpudl-storage-operation-monthly
core_eia923__monthly_energy_storage.parquet; report_date=2023; plant_id_eia=62745; prime_mover_code=storage prime movers
Operating nameplate capacity, latest inventory280.0MW2026-08-01reported / derivedvalideia860m-inventory
Preliminary Monthly Electric Generator Inventory, August 2026; plant_id_eia=62745; report_date=2026-08-01
Planned nameplate capacity, latest inventory—MW2026-08-01reported / derivednot_applicable (not_applicable)eia860m-inventory
Preliminary Monthly Electric Generator Inventory, August 2026; plant_id_eia=62745; report_date=2026-08-01
Retired or cancelled nameplate capacity, latest inventory—MW2026-08-01reported / derivednot_applicable (not_applicable)eia860m-inventory
Preliminary Monthly Electric Generator Inventory, August 2026; plant_id_eia=62745; report_date=2026-08-01
Net generation93,026MWh2020reported / derivedvalidpudl-output
out_eia923__yearly_generation_fuel_combined.parquet; report_date=2020-01-01; plant_id_eia=62745
Net generation713,534MWh2021reported / derivedvalidpudl-output
out_eia923__yearly_generation_fuel_combined.parquet; report_date=2021-01-01; plant_id_eia=62745
Net generation605,258MWh2022reported / derivedvalidpudl-output
out_eia923__yearly_generation_fuel_combined.parquet; report_date=2022-01-01; plant_id_eia=62745
Net generation682,120MWh2023reported / derivedvalidpudl-output
out_eia923__yearly_generation_fuel_combined.parquet; report_date=2023-01-01; plant_id_eia=62745

Sources

Each source's notice and terms: rights.json in this release.