| Fact | Value | Unit | Period | Evidence / method | Quality | Source and locator |
|---|---|---|---|---|---|---|
| Nameplate capacity, operating generators | 98.1 | MW | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195 |
| Generators listed | 7 | count | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195 |
| Operating generators | 7 | count | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195 |
| Net generation | 436,437 | MWh | 2024 | reported / derived | valid | pudl-output out_eia923__yearly_generation_fuel_combined.parquet; report_date=2024-01-01; plant_id_eia=2195 |
| Capacity factor | 0.506 | fraction | 2024 | reported / derived | valid | pudl-output derived: net_generation_mwh@2024 / (nameplate_mw_op x 8784 h) |
| Nameplate capacity | 7.0 | MW | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195; generator_id=TF1 |
| Net summer capacity | 7.5 | MW | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195; generator_id=TF1 |
| Net winter capacity | 7.5 | MW | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195; generator_id=TF1 |
| Nameplate capacity | 7.0 | MW | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195; generator_id=TF2 |
| Net summer capacity | 6.5 | MW | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195; generator_id=TF2 |
| Net winter capacity | 6.5 | MW | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195; generator_id=TF2 |
| Nameplate capacity | 7.0 | MW | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195; generator_id=TF3 |
| Net summer capacity | 7.5 | MW | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195; generator_id=TF3 |
| Net winter capacity | 7.5 | MW | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195; generator_id=TF3 |
| Nameplate capacity | 6.0 | MW | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195; generator_id=TF4 |
| Net summer capacity | 6.5 | MW | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195; generator_id=TF4 |
| Net winter capacity | 6.5 | MW | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195; generator_id=TF4 |
| Nameplate capacity | 7.0 | MW | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195; generator_id=TF5 |
| Net summer capacity | 6.0 | MW | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195; generator_id=TF5 |
| Net winter capacity | 6.5 | MW | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195; generator_id=TF5 |
| Nameplate capacity | 7.0 | MW | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195; generator_id=TF6 |
| Net summer capacity | 6.5 | MW | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195; generator_id=TF6 |
| Net winter capacity | 6.5 | MW | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195; generator_id=TF6 |
| Nameplate capacity | 57.1 | MW | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195; generator_id=TF7 |
| Net summer capacity | 53.0 | MW | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195; generator_id=TF7 |
| Net winter capacity | 53.0 | MW | 2024 | reported / derived | valid | pudl-generators out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=2195; generator_id=TF7 |
| Operating nameplate capacity, latest inventory | 91.1 | MW | 2026-08-01 | reported / derived | valid | eia860m-inventory Preliminary Monthly Electric Generator Inventory, August 2026; plant_id_eia=2195; report_date=2026-08-01 |
| Planned nameplate capacity, latest inventory | — | MW | 2026-08-01 | reported / derived | not_applicable (not_applicable) | eia860m-inventory Preliminary Monthly Electric Generator Inventory, August 2026; plant_id_eia=2195; report_date=2026-08-01 |
| Retired or cancelled nameplate capacity, latest inventory | — | MW | 2026-08-01 | reported / derived | not_applicable (not_applicable) | eia860m-inventory Preliminary Monthly Electric Generator Inventory, August 2026; plant_id_eia=2195; report_date=2026-08-01 |
| Net generation | 522,509 | MWh | 2015 | reported / derived | valid | pudl-output out_eia923__yearly_generation_fuel_combined.parquet; report_date=2015-01-01; plant_id_eia=2195 |
| Net generation | 510,256 | MWh | 2016 | reported / derived | valid | pudl-output out_eia923__yearly_generation_fuel_combined.parquet; report_date=2016-01-01; plant_id_eia=2195 |
| Net generation | 498,356 | MWh | 2017 | reported / derived | valid | pudl-output out_eia923__yearly_generation_fuel_combined.parquet; report_date=2017-01-01; plant_id_eia=2195 |
| Net generation | 460,628 | MWh | 2018 | reported / derived | valid | pudl-output out_eia923__yearly_generation_fuel_combined.parquet; report_date=2018-01-01; plant_id_eia=2195 |
| Net generation | 449,078 | MWh | 2019 | reported / derived | valid | pudl-output out_eia923__yearly_generation_fuel_combined.parquet; report_date=2019-01-01; plant_id_eia=2195 |
| Net generation | 480,176 | MWh | 2020 | reported / derived | valid | pudl-output out_eia923__yearly_generation_fuel_combined.parquet; report_date=2020-01-01; plant_id_eia=2195 |
| Net generation | 469,371 | MWh | 2021 | reported / derived | valid | pudl-output out_eia923__yearly_generation_fuel_combined.parquet; report_date=2021-01-01; plant_id_eia=2195 |
| Net generation | 496,704 | MWh | 2022 | reported / derived | valid | pudl-output out_eia923__yearly_generation_fuel_combined.parquet; report_date=2022-01-01; plant_id_eia=2195 |
| Net generation | 396,281 | MWh | 2023 | reported / derived | valid | pudl-output out_eia923__yearly_generation_fuel_combined.parquet; report_date=2023-01-01; plant_id_eia=2195 |