Koyle Ranch Hydroelectric Project

Entity plant:eia:10781 · release 20260929T050546Z-51ae0f7d3c78 · schema 1.41.0. Immutable citation page; values as published in this release. Current pages may be newer.

FactValueUnitPeriodEvidence / methodQualitySource and locator
Nameplate capacity, operating generators1.3MW2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=10781
Generators listed3count2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=10781
Operating generators3count2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=10781
Net generation3,775MWh2024reported / derivedvalidpudl-output
out_eia923__yearly_generation_fuel_combined.parquet; report_date=2024-01-01; plant_id_eia=10781
Capacity factor0.331fraction2024reported / derivedvalidpudl-output
derived: net_generation_mwh@2024 / (nameplate_mw_op x 8784 h)
Nameplate capacity0.2MW2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=10781; generator_id=GEN1
Net summer capacity0.2MW2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=10781; generator_id=GEN1
Net winter capacity0.2MW2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=10781; generator_id=GEN1
Nameplate capacity0.3MW2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=10781; generator_id=GEN2
Net summer capacity0.3MW2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=10781; generator_id=GEN2
Net winter capacity0.3MW2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=10781; generator_id=GEN2
Nameplate capacity0.8MW2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=10781; generator_id=GEN3
Net summer capacity0.8MW2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=10781; generator_id=GEN3
Net winter capacity0.7MW2024reported / derivedvalidpudl-generators
out_eia__yearly_generators.parquet; report_date=2024-01-01; plant_id_eia=10781; generator_id=GEN3
Operating nameplate capacity, latest inventory1.3MW2026-08-01reported / derivedvalideia860m-inventory
Preliminary Monthly Electric Generator Inventory, August 2026; plant_id_eia=10781; report_date=2026-08-01
Planned nameplate capacity, latest inventory—MW2026-08-01reported / derivednot_applicable (not_applicable)eia860m-inventory
Preliminary Monthly Electric Generator Inventory, August 2026; plant_id_eia=10781; report_date=2026-08-01
Retired or cancelled nameplate capacity, latest inventory—MW2026-08-01reported / derivednot_applicable (not_applicable)eia860m-inventory
Preliminary Monthly Electric Generator Inventory, August 2026; plant_id_eia=10781; report_date=2026-08-01
Net generation2,493MWh2015reported / derivedvalidpudl-output
out_eia923__yearly_generation_fuel_combined.parquet; report_date=2015-01-01; plant_id_eia=10781
Net generation3,331MWh2016reported / derivedvalidpudl-output
out_eia923__yearly_generation_fuel_combined.parquet; report_date=2016-01-01; plant_id_eia=10781
Net generation4,021MWh2017reported / derivedvalidpudl-output
out_eia923__yearly_generation_fuel_combined.parquet; report_date=2017-01-01; plant_id_eia=10781
Net generation3,410MWh2018reported / derivedvalidpudl-output
out_eia923__yearly_generation_fuel_combined.parquet; report_date=2018-01-01; plant_id_eia=10781
Net generation3,926MWh2019reported / derivedvalidpudl-output
out_eia923__yearly_generation_fuel_combined.parquet; report_date=2019-01-01; plant_id_eia=10781
Net generation3,582MWh2020reported / derivedvalidpudl-output
out_eia923__yearly_generation_fuel_combined.parquet; report_date=2020-01-01; plant_id_eia=10781
Net generation2,936MWh2021reported / derivedvalidpudl-output
out_eia923__yearly_generation_fuel_combined.parquet; report_date=2021-01-01; plant_id_eia=10781
Net generation2,439MWh2022reported / derivedvalidpudl-output
out_eia923__yearly_generation_fuel_combined.parquet; report_date=2022-01-01; plant_id_eia=10781
Net generation3,634MWh2023reported / derivedvalidpudl-output
out_eia923__yearly_generation_fuel_combined.parquet; report_date=2023-01-01; plant_id_eia=10781

Sources

Each source's notice and terms: rights.json in this release.